首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A recent conceptual model links higher bulk conductivities at hydrocarbon impacted sites to higher total dissolved solids (TDS) resulting from enhanced mineral weathering due to acids produced during biodegradation. In this study, we evaluated the above model by investigating the vertical distribution of bulk conductivity, TDS, and specific conductance in groundwater. The results showed higher TDS at contaminated locations consistent with the above model. Further, steep vertical gradients in bulk conductivity and TDS suggest vertical and spatial heterogeneity at the site. We observed that at fluid conductivities <40 mS/m, bulk conductivity was inversely related to fluid conductivity, but at fluid conductivities >40 mS/m, bulk conductivity increased with increasing fluid conductivity. However, at fluid conductivities >80 mS/m, bulk conductivities increased without a corresponding increase in fluid conductivity, resulting in a poor correlation between bulk conductivity and fluid conductivity for the contaminated samples. This suggests that electrolytic conductivity was not completely responsible for the observed variability in bulk conductivity. We suggest two possible reasons for the inverse relationship at low fluid conductivity and poor positive correlation at high fluid conductivity: (1) geochemical heterogeneity due to biological processes not captured at a scale comparable to the bulk conductivity measurement and (2) variability in the surface conductivity, consistent with a simple petrophysical model that suggests higher surface conductivity for contaminated sediments. We conclude that biodegradation processes can impact both electrolytic and surface conduction properties of contaminated sediments and these two factors can account for the higher bulk conductivities observed in sediments impacted by hydrocarbon.  相似文献   

2.
Considering heterogeneity in porous media pore size and connectivity is essential to predicting reactive solute transport across interfaces. However, exchange with less‐mobile porosity is rarely considered in surface water/groundwater recharge studies. Previous research indicates that a combination of pore‐fluid sampling and geoelectrical measurements can be used to quantify less‐mobile porosity exchange dynamics using the time‐varying relation between fluid and bulk electrical conductivity. For this study, we use macro‐scale (10 s of cm) advection–dispersion solute transport models linked with electrical conduction in COMSOL Multiphysics to explore less‐mobile porosity dynamics in two different types of observed sediment water interface porous media. Modeled sediment textures contrast from strongly layered streambed deposits to poorly sorted lakebed sands and cobbles. During simulated ionic tracer perturbations, a lag between fluid and bulk electrical conductivity, and the resultant hysteresis, is observed for all simulations indicating differential loading of pore spaces with tracer. Less‐mobile exchange parameters are determined graphically from these tracer time series data without the need for inverse numerical model simulation. In both sediment types, effective less‐mobile porosity exchange parameters are variable in response to changes in flow direction and fluid flux. These observed flow‐dependent effects directly impact local less‐mobile residence times and associated contact time for biogeochemical reaction. The simulations indicate that for the sediment textures explored here, less‐mobile porosity exchange is dominated by variable rates of advection through the domain, rather than diffusion of solute, for typical low‐to‐moderate rate (approximately 3–40 cm/day) hyporheic fluid fluxes. Overall, our model‐based results show that less‐mobile porosity may be expected in a range of natural hyporheic sediments and that changes in flowpath orientation and magnitude will impact less‐mobile exchange parameters. These temporal dynamics can be assessed with the geoelectrical experimental tracer method applied at laboratory and field scales.  相似文献   

3.
The studies on the physical properties of minerals and rocks in combination with the work in petrology, mineralogy and geochemistry are not only a useful mean to look into the composition and structure of the earth抯 interior, but also can provide extreme…  相似文献   

4.
The electrical properties of rocks and minerals are controlled by thermodynamic parameters like pressure and temperature and by the chemistry of the medium in which the charge carriers move. Four different charge transport processes can be distinguished. Electrolytic conduction in fluid saturated porous rocks depends on petrophysical properties, such as porosity, permeability and connectivity of the pore system, and on chemical parameters of the pore fluid like ion species, its concentration in the pore fluid and temperature. Additionally, electrochemical interactions between water dipoles or ions and the negatively charged mineral surface must be considered. In special geological settings electronic conduction can increase rock conductivities by several orders of magnitude if the highly conducting phases (graphite or ores) form an interconnected network. Electronic and electrolytic conduction depend moderately on pressure and temperature changes, while semiconduction in mineral phases forming the Earth’s mantle strongly depends on temperature and responds less significantly to pressure changes. Olivine exhibits thermally induced semiconduction under upper mantle conditions; if pressure and temperature exceed ~ 14 GPa and 1400 °C, the phase transition olivine into spinel will further enhance the conductivity due to structural changes from orthorhombic into cubic symmetry. The thermodynamic parameters (temperature, pressure) and oxygen fugacity control the formation, number and mobility of charge carriers. The conductivity temperature relation follows an Arrhenius behaviour, while oxygen fugacity controls the oxidation state of iron and thus the number of electrons acting as additional charge carriers. In volcanic areas rock conductivities may be enhanced by the formation of partial melts under the restriction that the molten phase is interconnected. These four charge transport mechanisms must be considered for the interpretation of geophysical field and borehole data. Laboratory data provide a reproducible and reliable database of electrical properties of homogenous mineral phases and heterogenous rock samples. The outcome of geoelectric models can thus be enhanced significantly. This review focuses on a compilation of fairly new advances in experimental laboratory work together with their explanation.  相似文献   

5.
Xunhong Chen 《水文研究》2011,25(2):278-287
Characterization of streambed hydraulic conductivity from the channel surface to a great depth below the channel surface can provide needed information for the determination of stream‐aquifer hydrologic connectedness, and it is also important to river restoration. However, knowledge on the streambed hydraulic conductivity for sediments 1 m below the channel surface is scarce. This study describes a method that was used to determine the distribution patterns of streambed hydraulic conductivity for sediments from channel surface to a depth of 15 m below. The method includes Geoprobe's direct‐push techniques and Permeameter tests. Direct‐push techniques were used to generate the electrical conductivity (EC) logs and to collect sequences of continuous sediment cores from river channels, as well as from the alluvial aquifer connected to the river. Permeameter tests on these sediment cores give the profiles of vertical hydraulic conductivity (Kv) of the channel sediments and the aquifer materials. This method was applied to produce Kv profiles for a streambed and an alluvial aquifer in the Platte River Valley of Nebraska, USA. Comparison and statistical analysis of the Kv profiles from the river channel and from the proximate alluvial aquifer indicates a special pattern of Kv in the channel sediments. This depth‐dependent pattern of Kv distribution for the channel sediments is considered to be produced by hyporheic processes. This Kv‐distribution pattern implied that the effect of hyporheic processes on streambed hydraulic conductivity can reach the sediments about 9 m below the channel surface. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
Frequency dependent electrical properties of minerals and partial-melts   总被引:4,自引:0,他引:4  
The resistance to current flow of minerals and partial-melts is a frequency dependent electrical property. Measurements of the frequency dependent electrical impedance of single crystal olivine, polycrystalline olivine, dunites, metapelites, and partial-melts, between 10–4 and 105 Hz, when plotted in the complex impedance plane, reveal arcs that correspond to different conduction mechanisms in the material being studied. In polycrystalline materials, two impedance arcs related to material properties (as opposed to electrode properties or electrode-sample interactions) are observed. Each impedance arc is activated over a distinct range of frequency, that is, the mechanisms occur in series. Based on experiments comparing single and polycrystalline impedance spectra, experiments on samples with different electrode configurations, and on samples of varying dimension, the mechanisms responsible for these impedance arcs are interpreted as grain interior conduction ( gi ), grain boundary conduction (in polycrystalline materials; gb ), and sample-electrode interface effects, from highest to lowest frequency, respectively. Impedance spectra of natural dunitic rocks reveal analogous behavior, that is, gb and gi add in series. The grain boundaries do not enhance the conductivity of any of the materials studied (a direct result of the observed series electrical behavior) and, under certain conditions, limit the total conductivity of the grain interior-grain boundary system. By examining the frequency dependence of the electrical properties of partial-melts, it is possible to gain information about microstructure and the distribution of the melt phase and to determine the conditions under which the presence of melt enhances the total conductivity. Impedance spectra of olivine-basalt partial-melts indicate that at least two conduction mechanisms occur in series over the frequency range 10–4-105 Hz, similar to the observed electrical response of melt-absent polycrystalline materials. In a sample containing isolated melt pockets the intermediate frequency grain boundary impedance arc is modified by the presence of melt indicating series conduction behavior. In a sample with an interconnected melt phase the high frequency grain interior impedance arc is modified by the melt phase, indicating the initiation of parallel conduction behavior. Because field EM response versus frequency curves are used to derive conductivity versus depth profiles, it is important to perform laboratory experiments to understand the frequency-dependent electrical behavior of Earth materials. Activation energies determined from studies that measure conductivity at a single frequency may be erroneous because of the shift of the dominant conduction mechanism with frequency as temperature is varied.  相似文献   

7.
Beyond KTB - electrical conductivity of the deep continental crust   总被引:8,自引:0,他引:8  
Great strides have been made in understanding the upper part of the crust by in-situ logging in, and laboratory experiments on core recovered from super-deep bore-holes such as the KTB. These boreholes do not extend into the lower crust, and can contribute little to the elucidation of mechanisms that produce the high electrical conductivities that are commonly observed therein by magneto-telluric (MT) methods. Laboratory studies at simulated lower crustal conditions of temperature, pressure and saturation, on electrolyte saturated rocks thought to have been derived from the lower crust, have not been possible up until now due to their experimental difficulty. It is necessary to subject electrolyte-saturated rock samples to independently controlled confining and pore-fluid pressure, which implies that the rock be sleeved in some impermeable but deformable material, that can withstand the very high temperatures required. Metals are the only materials capable of being used, but these cause great difficulties for cell sealing and conductivity measurement. In this paper we describe recent breakthroughs in experimental work, specifically the development of two new types of sophisticated metal/ceramic seal, and a conductivity measurement technique that enables the measurement of saturated rock conductivity in the presence of a highly conducting metallic sleeve. The advances in experimental technique have enabled us to obtain data on the electrical conductivity of brine saturated basic, acidic and graphite-bearing rocks at lower crustal temperatures and raised pressures. These data have facilitated the comparison of MT derived crustal electrical conductivity profiles with profiles obtained from laboratory experiments for the first time. Initial modelling shows a good agreement between laboratory derived and MT derived profiles only if the mid-crust is composed of amphibolite pervaded by aqueous fluids, and the lower crust is composed of granulite that is saturated with aqueous fluids and/or contains interconnected grain surface films of graphite. The experimental data are consistent with a three layer crust consisting of an aqueous fluid saturated acidic uppermost layer, above an aqueous fluid saturated amphibolite mid-crust, and a granulite lowermost crust, which may or may not be saturated with aqueous fluids, but if not, requires the presence of an additional conduction mechanism such as conduction through thin graphite films.  相似文献   

8.
Electromagnetic measurements have demonstrated that the lower continental crust has remarkable electrical anomalies of high conductivity and electrical anisotropy on a global scale (probably with some local exceptions), but their origin is a long-standing and controversial problem. Typical electrical properties of the lower continental crust include: (1) the electrical conductivity is usually 10−4 to 10−1 S/m; (2) the overlying shallow crust and underlying upper mantle are in most cases less conductive; (3) the electrical conductivity is statistically much higher in Phanerozoic than in Precambrian areas; (4) horizontal anisotropy has been resolved in many areas; and (5) in some regions there appear to be correlations between high electrical conductivity and other physical properties such as seismic reflections. The explanation based on conduction by interconnected, highly conductive phases such as fluids, melts, or graphite films in grain boundary zones has various problems in accounting for geophysically resolved electrical conductivity and other chemical and physical properties of the lower crust. The lower continental crust is dominated by mafic granulites (in particular beneath stable regions), with nominally anhydrous clinopyroxene, orthopyroxene, and plagioclase as the main assemblages, and the prevailing temperatures are mostly 700–1,000°C as estimated from xenolith data, surface heat flow, and seismic imaging. Pyroxenes have significantly higher Fe content in the lower crust than in the upper mantle (peridotites), and plagioclase has higher Na content in the lower crust than in the shallow crust (granites). Minerals in the lower continental crust generally contain trace amounts of water as H-related point defects, from less than 100 to more than 1,000 ppm H2O (by weight), with concentrations usually higher than those in the upper mantle. Observations of xenolith granulites captured by volcano-related eruptions indicate that the lower continental crust is characterized by alternating pyroxene-rich and plagioclase-rich layers. Experimental studies on typical lower crustal minerals have shown that their electrical conductivity can be significantly enhanced by the higher contents of Fe (for pyroxenes), Na (for plagioclase), and water (for all minerals) at thermodynamic conditions corresponding to the lower continental crust, e.g., to levels comparable to those measured by geophysical field surveys. Preferred orientation of hydrous plagioclase, e.g., due to ductile flow in the deep crust, and alternating mineral fabrics of pyroxene-rich and plagioclase-rich layers can lead to substantial anisotropy of electrical conductivity. Electrical conductivity properties in many regions of the lower continental crust, especially beneath stable areas, can mostly be accounted for by solid-state conduction due to the major constituents; other special, additional conduction mechanisms due to grain boundary phases are not strictly necessary.  相似文献   

9.
Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling‐based approaches are expensive and provide low‐density spatial and temporal information. Time‐lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation‐related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling‐based approaches for assessing emplacement and monitoring biostimulation‐based remediation. Field studies demonstrating the ability of time‐lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment‐related geochemical properties. Crosshole radar zero‐offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time‐lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost‐effective surface‐based ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance.  相似文献   

10.
Total organic carbon(TOC) and grain size distribution(sand,silt,and clay) in the ephemeral Mahi River(western India) sediments were measured to look at their effectiveness in understanding the late Quaternary monsoon conditions.Four sites spread across the alluvial zone and three sites from the estuarine zone were sampled.TOC concentration in the sediments of the alluvial and estuarine zone sites ranged between 0.04 and 0.39%and 0.04 and 0.23%,respectively.It was observed that grain size differed significantly at the alluvial zone sites,whereas an uniform trend was found in the estuarine zone sites.The study indicated that low concentration of TOC and coarse size fractions(sand) in sediments were well correlated with available records of arid/weaker palaeomonsoon periods,whereas higher concentration of TOC and fine grain size fractions(silt + clay) in sediments were well correlated with available records of enhanced palaeomonsoon periods of the ephemeral Mahi River.Uniform concentrations of TOC and fine grain size particles in sediments at the estuarine zone sites are attributed to the backwater in the system,deeper sedimentation,and/or greater decomposition processes.It is concluded that,TOC and grain size distributions in the ephemeraL river sediments are simple and effective parameters to develop an understanding about late Quaternary monsoon conditions in ephemeral rivers.  相似文献   

11.
Laboratory Electrical Conductivity Measurement of Mantle Minerals   总被引:4,自引:1,他引:3  
Electrical conductivity structures of the Earth’s mantle estimated from the magnetotelluric and geomagnetic deep sounding methods generally show increase of conductivity from 10−4–10−2 to 100 S/m with increasing depth to the top of the lower mantle. Although conductivity does not vary significantly in the lower mantle, the possible existence of a highly conductive layer has been proposed at the base of the lower mantle from geophysical modeling. The electrical properties of mantle rocks are controlled by thermodynamic parameters such as pressure, temperature and chemistry of the main constituent minerals. Laboratory electrical conductivity measurements of mantle minerals have been conducted under high pressure and high temperature conditions using solid medium high-pressure apparatus. To distinguish several charge transport mechanisms in mantle minerals, it is necessary to measure the electrical conductivity in a wider temperature range. Although the correspondence of data has not been yet established between each laboratory, an outline tendency of electrical conductivity of the mantle minerals is almost the same. Most of mineral phases forming the Earth’s mantle exhibit semiconductive behavior. Dominant conduction mechanism is small polaron conduction (electron hole hopping between ferrous and ferric iron), if these minerals contain iron. The phase transition olivine to high-pressure phases enhances the conductivity due to structural changes. As a result, electrical conductivity increases in order of olivine, wadsleyite and ringwoodite along the adiabat geotherm. The phase transition to post-spinel at the 660 km discontinuity further can enhance the conductivity. In the lower mantle, the conductivity once might decrease in the middle of the lower mantle due to the iron spin transition and then abruptly increase at the condition of the D″ layer. The impurities in the mantle minerals strongly control the formation, number and mobility of charge carriers. Hydrogen in nominally anhydrous minerals such as olivine and high-pressure polymorphs can enhance the conductivity by the proton conduction. However, proton conduction has lower activation enthalpy compared with small polaron conduction, a contribution of proton conduction becomes smaller at high temperatures, corresponding to the mantle condition. Rather high iron content in mantle minerals largely enhances the conductivity of the mantle. This review focuses on a compilation of fairly new advances in experimental laboratory work together with their explanation.  相似文献   

12.
在1.0 GPa压力、343~962 K温度和0.1~106Hz频率的条件下,使用Solartron 1260阻抗-增益/相位分析仪对含角闪石的片麻岩从平行和垂直面理两个不同方向分别进行了电阻抗的测定,并且进一步分析了片麻岩的微观导电机制.高温高压实验结果表明:片麻岩的复阻抗对温度、频率表现出明显的依赖性.片麻岩的电导...  相似文献   

13.
Understanding petrographical, geochemical and electrical properties of rocks is essential for investigating minerals. This paper presents a study of the petrographical, geochemical and A.C. electrical properties of carbonate rock samples. The samples collected show six lithostratigraphic rock units. Electrical properties were measured using a non‐polarizing electrode at room temperature (~20°C) and a relative atmospheric humidity of ~50% by weight in the frequency range from 42 Hz to 5 MHz. The difference in electrical properties between the samples was attributed to the change in composition and texture between the samples. Electrical properties generally change with many factors (grain size, chemical composition, grain shape and facies). The dielectric constant decreases with frequency and increases with conductor composition. The conductivity increases with the increase of conductor paths between electrodes. Many parameters can contribute to the same result of the electrical properties. The main objective of the present study is to shed more light on the relation between the texture and geochemical composition of measured samples (carbonates that contain clays and quartz grains) through electrical laboratory measurements (conductivity and dielectric constant as a function of frequency).  相似文献   

14.
王多君  马瑾  杨晓松  周平 《地震地质》2007,29(1):152-160
研究地幔矿物的电导率可以揭示地球内部电导率的分布规律以及地球介质的极化机制。通过对近年来国际上地幔矿物电导率的研究结果进行分析和总结,介绍了矿物的各种影响因素与电导率的关系;对含水和不含水的地幔矿物导电机制进行了区别,不含水矿物的导电机制主要为小极化子,含水矿物的导电机制为自由质子。比较了各种典型的地幔矿物电导率结果并对电导率模型进行了评述和总结,对电导率的研究方向进行了展望。认为水在地幔矿物电导率和电导率剖面中起着重要作用  相似文献   

15.
为了建立具有普遍适用性的上地幔电性结构,本文利用Kawai-1000t压机和Solartron IS-1260阻抗/增益-相位分析仪,在4.0~14.0 GPa、873~1673 K的条件下,采用交流阻抗谱法(频率范围10-1~106Hz)测量了不含水的地幔岩电导率.实验结果显示,岩石的电导率随温度升高而大幅度的增大;在较大的温度范围内岩石的导电机制发生了变化,中低温时为小极化子导电,此时激活焓为0.94 eV (±0.13) eV,激活体积为0.11(±0.92) cm3·mol-1,高温时为和镁空穴相关的离子导电,此时激活焓为1.6~3.17 eV,激活体积为6.75(±7.43) cm3·mol-1;本次测量的电导率比低压下岩石的电导率要高,比矿物的电导率也要高.用本次的实验结果回归计算得到Fennoscandian地区的上地幔的一维电导率剖面,发现200 km以上本次实验计算的结果和大地电磁测深的电导率剖面吻合的比较好,在200 km以下本次实验得到的要比野外测量的电导率稍稍高一点,可能是因为实验过程中没有完全避免水的影响.本次的实验结果比用有效均匀介质方法计算得到的pyrolite矿物模型的电导率要高出两个数量级,这样的结果显示只用一种矿物的电导率或是几种矿物理论计算的结果有一定的不合理性.  相似文献   

16.
A 3D ERT study of solute transport in a large experimental tank   总被引:2,自引:0,他引:2  
A high resolution, cross-borehole, 3D electrical resistivity tomography (ERT) study of solute transport was conducted in a large experimental tank. ERT voxels comprising the time sequence of electrical images were converted into a 3D array of ERT estimated fluid conductivity breakthrough curves and compared with direct measurements of fluid conductivity breakthrough made in wells. The 3D ERT images of solute transport behaviour were also compared with predictions based on a 3D finite-element, coupled flow and transport model, accounting for gravity induced flow caused by concentration differences.The tank (dimensions 185×245×186 cm) was filled with medium sand, with a gravel channel and a fine sand layer installed. This heterogeneous system was designed to complicate solute transport behaviour relative to a homogeneous sand tank, and to thus provide a challenging but insightful analysis of the ability of 3D ERT to resolve transport phenomena. Four ERT arrays and 20 piezometers were installed during filling. A NaCl tracer (conductivity 1.34 S/m) was injected and intensively monitored with 3D ERT and direct sampling of fluid chemistry in piezometers.We converted the bulk conductivity estimate for 250 voxels in the ERT imaged volume into ERT estimated voxel fluid conductivity by assuming that matrix conduction in the tank is negligible. In general, the ERT voxel response is in reasonable agreement with the shape of fluid conductivity breakthrough observed in six wells in which direct measurements of fluid conductivity were made. However, discrepancies occur, particularly at early times, which we attribute to differences between the scale of the image voxels and the fluid conductivity measurement, measurement errors mapped into the electrical inversion and artificial image roughness resulting from the inversion.ERT images revealed the 3D tracer distribution at 15 times after tracer injection. The general pattern and timing of solute breakthrough observed with ERT agreed with that predicted from the flow/transport modelling. However, the ERT images indicate a vertical component of tracer transport and preferential flow paths in the medium sand. We attribute this to transient vertical gradients established during tracer injection, and heterogeneity caused by sorting of the sand resulting from the filling procedure. In this study, ERT provided a unique dataset of 250 voxel breakthrough curves in 1.04 m3. The use of 3D ERT to generate an array of densely sampled estimated fluid conductivity breakthrough curves is a potentially powerful tool for quantifying solute transport processes.  相似文献   

17.
l INTRODUCTlONIn this study, formation of alluvial deltas was treated as a river-dominated type of topograPhy process,caused simply by sediment deposition from a channel into a wide basin. The influences of waves, tides,and density differences related to coastal effects were excluded. There have been numerous experimentalstUdies on river delta problems. For examPle, Shieh et al. (1988, 1997) used coarse sediment asexperimental material and revealed the development and the geometric simil…  相似文献   

18.
Fine-scale hydrostratigraphic features often play a critical role in controlling ground water flow and contaminant transport. Unfortunately, many conventional drilling- and geophysics-based approaches are rarely capable of describing these features at the level of detail needed for contaminant predictions and remediation designs. Previous work has shown that direct-push electrical conductivity (EC) logging can provide information about site hydrostratigraphy at a scale of relevance for contaminant transport investigations in many unconsolidated settings. In this study, we evaluate the resolution and quality of that information at a well-studied research site that is underlain by highly stratified alluvial sediments. Geologic and hydrologic data, conventional geophysical logs, and particle-size analyses are used to demonstrate the capability of direct-push EC logging for the delineation of fine-scale hydrostratigraphic features in saturated unconsolidated formations. When variations in pore-fluid chemistry are small, the electrical conductivity of saturated media is primarily a function of clay content, and hydrostratigraphic features can be described at a level of detail (<2.5 cm in thickness) that has not previously been possible in the absence of continuous cores. Series of direct-push EC logs can be used to map the lateral continuity of layers with non-negligible clay content and to develop important new insights into flow and transport at a site. However, in sand and gravel intervals with negligible clay, EC logging provides little information about hydrostratigraphic features. As with all electrical logging methods, some site-specific information about the relative importance of fluid and sediment contributions to electrical conductivity is needed. Ongoing research is directed at developing direct-push methods that allow EC logging, water sampling, and hydraulic testing to be done concurrently.  相似文献   

19.
Recent studies of electrical properties have clarified the important parameters governing electrical conductivity in minerals — temperature, oxygen fugacity, stoichiometry, iron content — and in porous rocks — shape and interconnections of fluid-filled pore spaces. These parameters are discussed in terms of: (1) how they contribute to bulk conduction mechanisms within minerals; and (2) how they pertain to the conditions of rocks in situ.  相似文献   

20.
含碳结构对龙门山断层带电导率影响的实验探索   总被引:1,自引:1,他引:0       下载免费PDF全文
碳是影响岩石电导率大小的一个重要因素,可能是造成龙门山断层带电导率异常的重要原因之一.为了研究不同的碳含量、矿物颗粒粒径与碳晶体结构对断层带电导率的影响,在干燥、常温、0.2~300 MPa的压力条件下实验研究了人工模拟断层泥样品(石英粉末与含碳粉末混合的样品,简称模拟样品)和采自映秀-北川断层八角庙剖面的天然断层岩样品(简称天然样品)的电导率.实验结果显示,当模拟样品中的含碳粉末连通时,电导率与碳体积率的关系符合逾渗理论模型;而含碳粉末未连通时,电导率随总孔隙度降低而指数性升高.同时模拟样品的电导率也随石英颗粒粒径的变化而发生改变.相比于模拟样品中的含碳粉末主要分布于石英颗粒支撑的孔隙中,天然样品中的碳则主要以碳膜的形式赋存在颗粒边缘,导致碳体积率相同的条件下,模拟样品的电导率小于天然样品.此外,天然样品的电导率(9×10~(-4)S·m~(-1))也要小于野外大地电磁探测的结果(0.03~0.1 S·m~(-1)).在今后的实验中还需要考虑在动态摩擦条件下对含有完整含碳结构的天然样品进行电导率的实验研究.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号