首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Previous research has shown that self‐centering steel plate shear walls (SC‐SPSWs) are capable of achieving enhanced seismic performance at multiple hazard levels, including recentering following design‐level earthquakes. When modeling SC‐SPSWs numerically, these studies considered an idealized tension‐only steel plate shear wall (SPSW) web plate behavior. Research has shown that web plate behavior is more complex than predicted by the idealized model, and web plates can provide more strength, stiffness, and energy dissipation than predicted by the idealized model. The idealized model of web plate behavior is used widely in SPSW numerical models where the moment‐resisting boundary frame provides supplemental hysteretic damping and stiffness; however, in SC‐SPSWs, where the post‐tensioned boundary frame is designed to remain elastic during an earthquake, accounting for the more complex web plate behavior can have a significant impact on seismic performance estimates from numerical simulation. This paper presents different methods for modeling SC‐SPSWs. Responses from these models are compared with experimental results. A simple modification of the tension‐only model, referred to as the tension‐compression strip model, is shown to provide a reasonable approximation of SC‐SPSW behavior. Results from nonlinear response history analyses of SC‐SPSWs with the tension‐only and tension‐compression web plate models are compared to assess how the approximation of web plate behavior affects SC‐SPSW seismic performance. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
Steel plate shear walls (SPSWs) are used as lateral force‐resisting systems in new and retrofitted structures in high‐seismic regions. Various international codes recommend the design of SPSWs assuming the entire lateral load to be resisted by the infill plates. Such a design procedure results in significant overstrength leading to uneconomical and inefficient use of materials. This study is focused on the estimation of contribution of boundary elements in resisting the lateral force considering their interaction with the web plates of SPSW systems. Initially, the relative contribution of web plates and boundary frames is computed for a single‐bay single‐story frame with varying rigidity and end connections of boundary elements. Nonlinear static analyses are carried out for the analytical models in OpenSees platform to quantify this contribution. Later, this study is extended to the code‐based designed three‐story, six‐story, and nine‐story SPSWs of varying aspect ratios. Based on the results obtained, a new design procedure is proposed taking the lateral strengths of the boundary frames into account. Nonlinear time‐history analyses are conducted for 40 recorded ground motions representing the design basis earthquake and maximum considered earthquake hazard levels to compare the interstory and residual drift response and yield mechanisms of SPSWs designed as per current practice and the proposed methodology. Finally, an expression has been proposed to predict the lateral force contribution of the infill plate and the boundary frame of SPSWs. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
This study consists of two parts. In this two‐part research, four two‐story narrow steel plate shear walls (SPSWs) were cyclically tested at the Taiwan National Center for Research on Earthquake Engineering in 2007. This paper, Part 1, proposes a capacity design method for the first‐story boundary column of the SPSW to ensure that the plastic hinges form at the column bottom ends when the SPSW develops the plastic mechanism. The design method was developed based on the superposition method considering the frame sway action and the panel force effects of the SPSW. Restrained steel plate shear wall (R‐SPSW) studied herein adopts pairs of the horizontal restrainers sandwiching over both sides of the infill panels and connected to the boundary columns. Analytical studies on four SPSW example designs using nonlinear finite element (FE) models and the simplified strip models confirm that the restrainers could also effectively reduce the column force demands and allow the infill panel to stretch more uniformly. In addition, the FE analytical studies verify the effectiveness of the proposed column capacity design method and the seismic design recommendations for the restrainer. This paper introduces the designs of the four narrow SPSW specimens, presenting the selections of the boundary beams and columns, the designs of the beam‐to‐column connections and the construction details of the restrainers. The experimental results, key observations and the design implications are reported in the companion paper. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
The steel plate shear wall (SPSW) is an effective lateral force resisting system in which unstiffened steel infill plates are connected to the horizontal and vertical boundary elements (VBEs) on all sides of the plates. The boundary elements must be designed to resist the tension field force of the infill panels. When the VBEs are made from a steel box section, the flange of each box VBE connected with the infill panels can be pulled out‐of‐plane by significant panel forces, called pull‐out action. This study investigates capacity design methods for box VBEs in SPSWs. Simplified fixed beam and portal frame models aim to estimate the pull‐out responses of the flange of the box sections with and without infill concrete, respectively. In this study, cyclic tests of three full‐scale two‐story SPSWs using box VBEs with or without the infill concrete are conducted. Inelastic pushover analyses of the finite element models are conducted. The tests and analytical results confirm that the proposed design methods, which aimed to prevent the full yield of the flange under the pull‐out action, are applicable. Furthermore, the test and analytical results suggest that the initial yielding of the flange of box VBEs under the collective effects of the pull‐out action on the flange, the gravity load, and the sway action on the SPSW represents a local yielding. A strict prohibition of the initial yielding on the flange under the aforementioned collective effects is not recommended for pursuing a cost‐effective design. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

5.
The coupled steel plate shear wall (C-SPSW) configuration has been investigated by researchers as a means of improving the overturning stiffness and architectural flexibility of SPSW structures. While C-SPSWs have been shown to exhibit excellent seismic performance, the fabrication cost associated with the high number of moment-resisting connections used in such systems is a potential detraction to their use as an economical solution. Past research has shown that the hysteresis response of SPSWs with simple frame connections is significantly pinched, and as such, most seismic codes prohibit their use in high seismic areas. However, when used in the C-SPSW configuration, a dual system is formed in which the coupling beams not only improve resistance to overturning but also provide substantial lateral strength and energy dissipation capacity. This paper presents an exploration of the potential to improve the economy of C-SPSWs by using the simple boundary frame connections. First, employing the principles of plastic analysis, an attempt is made to quantify the contribution of the coupling beams to the overall lateral load resistance of the system. Then, to evaluate the seismic performance of such C-SPSW systems and allow for the comparison with that of the C-SPSWs with rigid frames, several prototypes are designed and analyzed using a series of nonlinear response history and pushover analyses. The results indicated that the C-SPSWs with simple boundary frames exhibited satisfactory seismic performance comparable with that of the C-SPSWs with rigid frames under both the 10/50 and 2/50 hazard levels, while allowing for reduced fabrication costs.  相似文献   

6.
This paper describes an experiment to investigate the seismic design and responses of the bottom column, also called the bottom vertical boundary element (VBE), in steel plate shear walls (SPSWs). The main objectives of this experiment include validating the effectiveness of the design method developed in the companion paper, investigating the experimental performance of VBEs under large interstory drifts, and calibrating analytical models for earthquake engineering of SPSWs. Three full‐scale two‐story SPSWs were cyclically tested at the Taiwan National Center for Research on Earthquake Engineering in 2011. Test results and numerical simulations confirm that the proposed design procedures are effective in predicting the plastic zone forming elevation in the lower half of the bottom VBE and the occurrence of yielding at the VBE's top end. Test results show that the premature yielding occurring at the top end of a bottom VBE would result in a deformation concentration at the bottom of SPSWs. In addition, lateral torsional buckling could take place on the bottom VBE after significant plastic rotations have developed at the top end. Test results suggest that preventing the VBE's top end from yielding is the key issue in the seismic design of SPSWs, and the proposed method can be effectively adopted to achieve this objective. Furthermore, the inelastic responses of the SPSW specimens were satisfactorily simulated by using detailed finite shell elements or simplified frame response analysis models. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
This research investigates the seismic design method and the cyclic inelastic behavior of the bottom column, also called the vertical boundary element (VBE), in steel plate shear walls (SPSWs). This study consists of two parts. This Part 1 paper discusses the anticipated pushover responses for properly designed SPSWs and the possible inelastic responses of the bottom VBE at various levels of inter‐story drift. Considering both the tension field action of the infill panel and the sway action of the boundary frame, this study develops a simplified method to compute the flexural and shear demands in the bottom VBE. Based on the superposition method, this approach considers various plastic hinge forming locations at different levels of inter‐story drift. One of the key performance‐based design objectives is to ensure that the top ends of the bottom VBEs remain elastic when the SPSWs are subjected to the maximum considered earthquake. This paper presents the comprehensive design procedures for the bottom VBE. Furthermore, this study conducted cyclic performance evaluation tests of three full‐scale two‐story SPSWs at the Taiwan National Center for Research on Earthquake Engineering in 2011 to validate the effectiveness of the proposed design methods. The experimental program, cyclic inelastic responses of the SPSWs and bottom VBEs, and numerical simulations are presented in Part 2. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
This paper is the second part of a two‐part paper presenting the cyclic tests of four two‐story narrow steel plate shear walls (SPSWs). The first paper introduces the analytical studies and the specimen designs. This paper describes the test results. Some design implications including the capacity design for the first story column and the width‐to‐thickness ratio check for the beam web are discussed based on key observations from the tests. Test results confirm that the simplified strip model can accurately predict the inelastic responses of the specimens. Test results also confirm that the proposed capacity design method is effective in ensuring the plastic hinge formation at the bottom end of the first story column for SPSW with or without restrainers. Test results also show that the horizontal restrainers are effective in reducing the member forces in the boundary beam and column elements. Comparing the test results of the typical SPSW with those of the restrained SPSW (R‐SPSW) specimens, it is found that the R‐SPSW possesses an improved cyclic performance and reduced material weight. Analytical results predict the compressed column moments at the onset of the column plastic hinge formation well. The analytical hysteretic energy distribution in the first story column agrees very well with the observed inelastic actions developed in the four specimens. The detailed frame response analyses and the test results confirm that the assumptions made in developing the proposed column capacity design method are reasonable. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Coupled steel plate shear wall (C‐SPSW) consists of two or more steel plate shear walls interconnected by coupling beams at the floor levels. In this study, a six‐story C‐SPSW prototype building was designed. A 40% scale C‐SPSW specimen, which is representative of the bottom two‐and‐half‐story substructure of the prototype, was cyclically tested using Multi‐Axial Testing System at the National Center for Research on Earthquake Engineering in 2009. In addition to a constant vertical force representing the gravity load effects, cyclic increasing displacements and the corresponding overturning moments transmitted from the upper stories were computed online and simultaneously applied on the substructural specimen. This paper firstly introduces the designs of the prototype C‐SPSW and the test specimen. Then, the test results and the numerical simulation are discussed in detail. Test results confirm the effectiveness of the proposed column capacity design method, which aims at limiting the plastic hinge formation within the bottom quarter height of the bottom column. Test and analytical results suggest that the coupling beam rotational demands can be estimated as the design story drifts when the formation of desirable plastic mechanism of the C‐SPSW is expected. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
The seismic performance of composite steel plate shear walls (CSPSWs) that consist of a steel plate shear wall (SPSW) with reinforced concrete (RC) panels attached to one or both sides by means of bolts or connectors is experimentally studied. The shear wall is connected to the frame beams but not to the columns. This arrangement restrains the possible out-of-plane buckling of the thin-walled steel plate, thus significantly increasing the bearing capacity and ductility of the overall wall, and prevents the premature overall or local buckling failure of the frame columns. From a practical viewpoint, these solutions can provide open space in a floor as this type of composite shear walls with a relatively small aspect ratio can be placed parallel along a bay. In this study, four CSPSWs and one SPSW were tested and the results showed that both CSPSWs and SPSW possessed good ductility. For SPSW alone, the buckling appeared and resulted in a decrease of bearing capacity and energy dissipation capacity. In addition, welding stiffeners at corners were shown to be an effective way to increase the energy dissipation capacity of CSPSWs.  相似文献   

11.
Unstiffened steel plate shear walls (SPSWs) are used as lateral load‐resisting systems in building structures. The energy dissipation mechanism of SPSWs consists of the tension yielding of web plates and the formation of plastic hinges at the ends of horizontal boundary elements. However, vertical boundary elements (VBEs) of high‐rise SPSWs may experience high axial forces under lateral loading. This study explores the effectiveness of staggering of web plates on the reduction of VBE forces and drift response of SPSWs during an earthquake event. An analytical study has been conducted to determine the base shear reduction factor so as to match the overstrength of staggered systems with conventional SPSWs. A design methodology has been proposed for staggered SPSWs. Six‐, 9‐, and 20‐storey staggered and conventional SPSWs with varying aspect ratios are considered in this study to compare their seismic response. These study frames are modelled and analysed in OpenSEES platform. Nonlinear static and dynamic analyses are performed to compare the drift response, hinge mechanisms, and steel tonnage. Staggered SPSWs showed uniform drift distribution and reduction in interstorey drift and axial force demand on the VBEs.  相似文献   

12.
A new type of steel plate shear wall (SPSW) with oval-curved architectural openings and vertically flexible horizontal connection elements is proposed. The vertical flexibility of the wall accommodates the construction settlement introduced by column contraction under the dead loads of the upper stories and allows sequential installation from the lower stories. A quasi-static cyclic loading test and finite element (FE) analysis verified the stable seismic behaviors of the ovally-perforated vertically-flexible steel plate shear wall (OVSPW). The results of FE parametric analysis showed that an OVSPW with an appropriate thickness of boundary elements effectively accommodated the construction settlement that could lead to large in-plane compression for a conventional SPSW. The horizontal connection elements made of steel tubes realized the vertical stiffness of OVSPW to less than 2% of the original value without changing the lateral stiffness. New design equations of the OVSPW were derived through integral and extreme value solutions to predict the mechanical behavior of OVSPW.  相似文献   

13.
联肢钢板剪力墙能通过连梁耗能实现多重抗侧体系,其优良的抗震性能被越来越多的学者研究论证。本文基于能量平衡原理和Chao和Goel提出的弹塑性层剪力分布模式,预设目标侧移及屈服机制等性能参数,归纳出完整的联肢钢板剪力墙结构塑性设计流程,并采用该方法基于8度(0.3g)抗震设防条件下设计了12个联肢钢板剪力墙结构算例。利用有限元分析软件ABAQUS对结构进行了Push-over分析,研究了刚度退化、构件屈服顺序和结构整体变形等方面的结果。结果表明:设计算例能够实现多重抗震机制,并满足预期性能目标。  相似文献   

14.
Presence of irregularities in reinforced concrete (RC) buildings increases seismic vulnerability. During severe seismic shaking, such buildings may suffer disproportionate damage or even collapse that can be minimized by increasing robustness. Robustness is a desirable property of structural systems that can mitigate susceptible buildings to disproportionate collapse. In this paper, the effects of vertical irregularity and thickness of unreinforced masonry infill on the robustness of a six‐story three‐bay RC frame are quantified. Nonlinear static analysis of the frame is performed, and parametric study is undertaken by considering two parameters: absence of masonry infill at different floors (i.e., vertical irregularities) and infill thickness. Robustness has been quantified in terms of stiffness, base shear, ductility, and energy dissipation capacity of the frame. It was observed that the infill thickness and vertical irregularity have significant influence on the response of RC frame. The response surface method is used to develop a predictive equation for robustness as a function of the two parameters. The predictive equation is validated further using 12 randomly selected computer simulations. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
本文针对钢板剪力墙结构自振周期缺乏研究的现状,将钢板剪力墙简化为Timoshenko梁,提出了考虑周边框架影响的钢板剪力墙等效抗剪刚度计算的方法,然后根据Southwell-Dunkerley理论,给出了钢板剪力墙结构基本自振周期的简化计算公式。然后,通过56个算例比较分析了本文公式计算结果与有限元计算结果发现:本文公式计算结果与有限元结果之比的平均值为1.015,标准差为0.049,说明本文公式具有足够的可靠性。接着,又对结构高度、均布质量、等效抗剪、抗弯刚度、钢板的高厚比、高宽比等参数进行了分析,分析结果表明:随着结构高度与均布质量开方的乘积增大,结构的基本自振周期增长;层数相同时,随着等效抗剪刚度、抗弯刚度的增大,周期有减小的趋势;层数相同时,随着钢板高厚比与高宽比乘积的增大,周期增长。  相似文献   

16.
This study assesses the seismic performance of a hybrid coupled wall (HCW) system with replaceable steel coupling beams (RSCBs) at four intensities of ground motion shaking. The performance of the HCW system is benchmarked against the traditional reinforced concrete coupled wall (RCW). Nonlinear numerical models are developed in OpenSees for a representative wall elevation in a prototype 11‐story building designed per modern Chinese codes. Performance is assessed via nonlinear dynamic analysis. The results indicate that both systems can adequately meet code defined objectives in terms of global and component behavior. Behavior of the two systems is consistent under service level earthquakes, whereas under more extreme events, the HCW system illustrates enhanced performance over the RCW system resulting in peak interstory drifts up to 31% lower in the HCW than the RCW. Larger drifts in the RCW are because of reduced coupling action induced by stiffness degradation of RC coupling beams, whereas the stable hysteretic responses and overstrength of RSCBs benefit post‐yield behavior of the HCW. Under extreme events, the maximum beam rotations of the RSCBs are up to 42% smaller than those of the RC coupling beams. Moderate to severe damage is expected in the RC coupling beams, whereas the RSCBs sustain damage to the slab above the beam and possible web buckling of shear links. The assessment illustrates the benefits of the HCW with RSCBs over the RCW system, because of easy replacement of the shear links as opposed to costly and time‐consuming repairs of RC coupling beams. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

17.
Motivated by the seismic damage observed to reinforced concrete (RC) frame structures during the Wenchuan earthquake, the effect of infill walls on the seismic performance of a RC frame is studied in this paper. Infill walls, especially those made of masonry, offer some amount of stiffness and strength. Therefore, the effect of infill walls should be considered during the design of RC frames. In this study, an analysis of the recorded ground motion in the Wenchuan earthquake is performed. Then, a numerical model is developed to simulate the infill walls. Finally, nonlinear dynamic analysis is carried out on a RC frame with and without infill walls, respectively, by using CANNY software. Through a comparative analysis, the following conclusions can be drawn. The failure mode of the frame with infill walls is in accordance with the seismic damage failure pattern, which is strong beam and weak column mode. This indicates that the infill walls change the failure pattern of the frame, and it is necessary to consider them in the seismic design of the RC frame. The numerical model presented in this paper can effectively simulate the effect of infill walls on the RC frame.  相似文献   

18.
为研究填充墙对底层框架多层砌体房屋地震反应的影响,以典型的填充墙-底层框架多层砌体房屋为基础,建立有限元计算模型并进行了弹塑性动力时程分析。根据不同模型的计算结果以及填充墙的刚度和强度,分析了填充墙对底层框架多层砌体房屋自振周期、地震作用下房屋整体变形、底层框架的损伤以及填充墙与底层框架相互作用的影响。计算结果表明:填充墙对房屋整体地震反应产生明显影响,其影响不能忽略。在上部砌体结构质量和刚度不变的情况下,结构自振周期随着填充墙刚度的增加而降低;随着填充墙与底层框架之间连接作用的增强,结构整体的变形减小,底层框架的损伤增大。当填充墙与底层框架之间采用弱连接时,采用强度较高的填充墙可以提高结构整体的变形能力,从而提高结构整体的抗震能力。  相似文献   

19.
Design recommendations for steel plate shear wall (SPSW) systems have recently been introduced into seismic provisions for steel buildings. Response modification (R), overstrength (Ωo), and displacement amplification (Cd) factors for SPSW systems presented in design codes were based on professional experience and judgment. A numerical study has been undertaken to evaluate these factors for SPSW systems. Forty‐four unstiffened SPSW possessing different geometrical characteristics were designed based on the recommendations given in the AISC Seismic Provisions. Bay width, number of stories, story mass, and steel plate thickness were considered as the prime variables that influence the response. Twenty records were selected to include the variability in ground motion characteristics. In order to provide a detailed analysis of the post‐buckling response, three‐dimensional finite element analyses were conducted for the 44 structures subjected to the selected suite of earthquake records. For each structure and earthquake record, two analyses were conducted in which the first includes geometrical nonlinearities and the other includes both geometrical and material nonlinearities, resulting in a total of 1760 time history analyses. In this paper, the details of the design and analysis methodology are given. Based on the analysis results, response modification (R), overstrength (Ωo), and displacement amplification (Cd) factors for SPSW systems are evaluated. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
This paper presents an analytical investigation on the seismic design and response of coupled wall structures that use unbonded post‐tensioned steel coupling beams. Both monolithic cast‐in‐place reinforced concrete wall piers and precast concrete wall piers are considered. Steel top and seat angles are used at the coupling beam ends for energy dissipation. The seismic design of prototype structures to achieve target displacement‐based performance objectives is evaluated based on nonlinear static and dynamic time history analyses. Additional recommendations are provided on shear design. Comparisons with ‘conventional’ structures that use embedded steel coupling beams as well as isolated walls with no coupling are provided. The results indicate that while the peak lateral displacements of unbonded post‐tensioned coupled wall structures are larger than the peak displacements of structures with embedded beams, the residual displacements are significantly reduced as a result of the restoring effect of the post‐tensioning steel. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号