首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
强震下的水闸结构抗震性能尚待深入研究,结合实际工程案例,运用UC-WCOMD有限元分析软件建立精细化的水闸计算模型,并分别采用Pushover法和时程分析法讨论水闸在强震作用下的抗震性能,结果表明:结合抗震设防目标,采用Pushover分析法评估水闸的抗侧能力,并采用弹塑性时程分析方法进行强震下的抗震性能校核,是值得推荐的研究方法。  相似文献   

2.
The effects of higher modes and torsion have a significant impact on the seismic responses of asymmetric-plan tall buildings.A consecutive modal pushover(CMP) procedure is one of the pushover methods that have been developed to consider these effects.The aim of this paper is to modify the(CMP) analysis procedure to estimate the seismic demands of one-way asymmetric-plan tall buildings with dual systems.An analysis of 10-,15-and 20-story asymmetric-plan buildings is carried out,and the results from the modified consecutive modal pushover(MCMP) procedure are compared with those obtained from the modal pushover analysis(MPA) procedure and the nonlinear time history analysis(NLTHA).The MCMP estimates of the seismic demands of one-way asymmetric-plan buildings demonstrate a reasonable accuracy,compared to the results obtained from the NLTHA.Furthermore,the accuracy of the MCMP procedure in the prediction of plastic hinge rotations is better than the MPA procedure.The new pushover procedure is also more accurate than the FEMA load distribution and the MPA procedure.  相似文献   

3.
For modal pushover analysis procedures, the model proposed by Ghobarah et al. (called the G model hereafter, 1999) has been extended to account for the contributions of transient higher modes to global seismic damage of structures excited by strong ground motions. The proposed model has physically and perfectly bridged the G model and the final softening model proposed by DiPasquale and Cakmak (1988). Modal damage indexes corresponding to all considered vibration modes are combined by the CQC rule or the SRSS rule. Incremental dynamic analysis (IDA) is performed on three example RC frames to validate the proposed model, and a comprehensive comparison is carried out. The demonstration indicates that the proposed model is easy to implement and reflects the influence of the transition in transient vibration periods and modes on structural damage evolution. Some limitations associated with the proposed model are also addressed. Further experimental validations are needed to improve the model in the future.  相似文献   

4.
延性需求谱在基于性能的抗震设计中的应用   总被引:19,自引:4,他引:19  
基于性能的抗震设计理论涉及如何简便而合理地确定结构在指定强度地震下的弹塑性位移需求。本文给出了利用延性需求谱求解结构位移需求的一般步骤:借助模态Pushover分析将多自由度体系分解为几个非线性单自由度体系,以考虑各阶振型的影响;利用延性需求谱计算对应模态的等效单自由度体系的延性及位移需求,并以一定方式组合转化为多自由度体系位移需求。最后,通过算例分析表明:利用延性需求谱求解结构位移需求是一种具有一定精度可为工程接受的简便方法,在基于性能的抗震设计中具有较好的应用前景。  相似文献   

5.
An Erratum has been published for this article in Earthquake Engng. Struct. Dyn. 2004; 33:1429. Based on structural dynamics theory, the modal pushover analysis (MPA) procedure retains the conceptual simplicity of current procedures with invariant force distribution, now common in structural engineering practice. The MPA procedure for estimating seismic demands is extended to unsymmetric‐plan buildings. In the MPA procedure, the seismic demand due to individual terms in the modal expansion of the effective earthquake forces is determined by non‐linear static analysis using the inertia force distribution for each mode, which for unsymmetric buildings includes two lateral forces and torque at each floor level. These ‘modal’ demands due to the first few terms of the modal expansion are then combined by the CQC rule to obtain an estimate of the total seismic demand for inelastic systems. When applied to elastic systems, the MPA procedure is equivalent to standard response spectrum analysis (RSA). The MPA estimates of seismic demand for torsionally‐stiff and torsionally‐flexible unsymmetric systems are shown to be similarly accurate as they are for the symmetric building; however, the results deteriorate for a torsionally‐similarly‐stiff unsymmetric‐plan system and the ground motion considered because (a) elastic modes are strongly coupled, and (b) roof displacement is underestimated by the CQC modal combination rule (which would also limit accuracy of RSA for linearly elastic systems). Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

6.
根据黏弹性阻尼器的特点和抗震规范的要求,分别提出了用于黏弹性阻尼器减震结构抗震分析的弹性及弹塑性需求谱,前者是基于黏弹性阻尼器减震结构等效阻尼比的简化计算公式及规范规定的反应谱;后者是基于修正的V id icRμ-μ-T关系。在此基础上,借助模态推覆分析,提出了可以考虑高阶振型影响的黏弹性阻尼器消能减震结构体系的能力谱分析方法,并对一8层钢筋混凝土消能减震框架结构进行了"中震不坏,大震可修"性能水准下的抗震分析。算例结果表明,采用该方法分析黏弹性阻尼器减震结构体系是可行的、有效的。  相似文献   

7.
《建筑工程抗震性态设计通则(试用)》对抗震设计具有重要的指导意义,其中的抗震设计理念同以往的抗震设计规范在抗震设防的思路、概念和方法上有较大的区别。从工程实践的角度,比较了《通则》和现行抗震设计相关规范的区别并对具体应用提出一些看法。  相似文献   

8.
性态抗震设计已成为结构抗震设计的发展趋势,本文以约束混凝土砌块结构为对象,在提出约束混凝土砌块墙承载力计算公式的基础上,建立了砌块墙片的恢复力模型。对3座不同层数的典型约束混凝土砌块结构,在代表不同场地类别、不同地震动强度的输入下分别进行了动力非线性时程分析和静力非线性分析。通过计算结果的对比,讨论了2种分析方法中场地类别、地震动强度、静力非线性分析中侧力分布模式等影响,所得结论可以为用静力非线性分析估计砌块结构的抗震性能提供有益的参考依据。  相似文献   

9.
Lateral load pattern in pushover analysis   总被引:9,自引:2,他引:7  
The seismic capacity curves of three types of buildings including frame, frame-shear wall and shear wall obtained by pushover analysis under different lateral load patterns are compared with those from nonlinear time history analysis. Based on the numerical results obtained a two-phase load pattern; an inverted triangle (first mode) load pattern until the base shear force reachesβ times its maximum value, Vmax, followed by a (x/H)α form, hereβ and α being some coefficients depending on the type of the structures considered, is proposed in the paper, which can provide excellent approximation of the seismic capacity curve for low-to-mid-rise shear type buildings. Furthermore, it is shown both the two-phase load pattern proposed and the invariant uniform pattern can be used for low-to-mid-rise shear-bending type and low-rise bending type of buildings. No suitable load patterns have been found for high-rise buildings.  相似文献   

10.
Nonlinear static (pushover) analysis has become a popular tool during the last decade for the seismic assessment of buildings. Nevertheless, its main advantage of lower computational cost compared to nonlinear dynamic time‐history analysis (THA) is counter‐balanced by its inherent restriction to structures wherein the fundamental mode dominates the response. Extension of the pushover approach to consider higher modes effects has attracted attention, but such work has hitherto focused mainly on buildings, while corresponding work on bridges has been very limited. Hence, the aim of this study is to adapt the modal pushover analysis procedure for the assessment of bridges, and investigate its applicability in the case of an existing, long and curved, bridge, designed according to current seismic codes; this bridge is assessed using three nonlinear static analysis methods, as well as THA. Comparative evaluation of the calculated response of the bridge illustrates the applicability and potential of the modal pushover method for bridges, and quantifies its relative accuracy compared to that obtained through other inelastic methods. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

11.
Assessment of seismic design response factors of concrete wall buildings   总被引:1,自引:2,他引:1  
To verify the seismic design response factors of high-rise buildings, five reference structures, varying in height from 20- to 60-stories, were selected and designed according to modern design codes to represent a wide range of concrete wall structures. Verified fiber-based analytical models for inelastic simulation were developed, considering the geometric nonlinearity and material inelasticity of the structural members. The ground motion uncertainty was accounted for by employing 20 earthquake records representing two seismic scenarios, consistent with the latest understanding of the tectonic setting and seismicity of the selected reference region (UAE). A large number of Inelastic Pushover Analyses (IPAs) and Incremental Dynamic Collapse Analyses (IDCAs) were deployed for the reference structures to estimate the seismic design response factors. It is concluded that the factors adopted by the design code are adequately conservative. The results of this systematic assessment of seismic design response factors apply to a wide variety of contemporary concrete wall buildings with various characteristics.  相似文献   

12.
Predictors of seismic structural demands (such as inter‐storey drift angles) that are less time‐consuming than nonlinear dynamic analysis have proven useful for structural performance assessment and for design. Luco and Cornell previously proposed a simple predictor that extends the idea of modal superposition (of the first two modes) with the square‐root‐of‐sum‐of‐squares (SRSS) rule by taking a first‐mode inelastic spectral displacement into account. This predictor achieved a significant improvement over simply using the response of an elastic oscillator; however, it cannot capture well large displacements caused by local yielding. A possible improvement of Luco's predictor is discussed in this paper, where it is proposed to consider three enhancements: (i) a post‐elastic first‐mode shape approximated by the deflected shape from a nonlinear static pushover analysis (NSPA) at the step corresponding to the maximum drift of an equivalent inelastic single‐degree‐of‐freedom (SDOF) system, (ii) a trilinear backbone curve for the SDOF system, and (iii) the elastic third‐mode response for long‐period buildings. Numerical examples demonstrate that the proposed predictor is less biased and results in less dispersion than Luco's original predictor. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

13.
Performance-based concept on seismic evaluation of existing bridges   总被引:1,自引:0,他引:1  
Conventional seismic evaluation of existing bridges explores the ability of a bridge to survive under significant earthquake excitations. This approach has several major drawbacks, such as only a single structural performance of near collapse is considered, and the simplified approach of adopting strength-based concept to indirectly estimate the nonlinear behavior of a structure lacks accuracy. As a result, performance-based concepts that include a wider variety of structural performance states of a given bridge excited by different levels of earthquake intensity is needed by the engineering community. This paper introduces an improved process for the seismic evaluation of existing bridges. The relationship between the overall structural performance and earthquakes with varying levels of peak ground acceleration (PGA) can successfully be linked. A universal perspective on the seismic evaluation of bridges over their entire life-cycle can be easily obtained to investigate multiple performance objectives. The accuracy of the proposed method, based on pushover analysis, is proven in a case study that compares the results from the proposed procedure with additional nonlinear time history analyses.  相似文献   

14.
Simplified seismic sidesway collapse analysis of frame buildings   总被引:1,自引:0,他引:1       下载免费PDF全文
This paper presents the development and assessment of a simplified procedure for estimating the seismic sidesway collapse margin ratio of building structures. The proposed procedure is based on the development of a robust database of seismic peak displacement responses of nonlinear single‐degree‐of‐freedom systems for various seismic intensities and uses nonlinear static (pushover) analysis without the need for nonlinear time history dynamic analysis. The proposed simplified procedure is assessed by comparing its collapse capacity predictions on 72 different building structures with those obtained by nonlinear incremental dynamic analyses. The proposed simplified procedure offers a simple, yet efficient, computational/analytical tool that is capable of predicting collapse capacities with acceptable accuracy for a wide variety of frame building structures. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
A risk-targeted design spectral acceleration and the corresponding seismic design action for the force-based design of structures is introduced by means of two formulations. The first one called direct formulation utilizes the seismic hazard function at the site of the structure. Because the seismic action defined in the codes is often associated with a designated return period, an indirect formulation is also introduced. It incorporates a risk-targeted safety factor that can be used to define a risk-targeted reduction factor. It is shown that the proposed formulations give analogical results and provide an insight into the concept of the reduction of seismic forces for the force-based seismic design of structures if the objective is defined by a target collapse risk. The introduced closed-form solution for the risk-targeted reduction factor can be used to investigate how the target collapse risk, the seismic hazard parameters, the randomness of the seismic action, and the conventional parameters (ie, the overstrength factor and the deformation and energy dissipation capacity) affect the seismic design forces in the case of force-based design. However, collaborative research is needed in order to develop appropriate models of these parameters. In the second part of the paper, the proposed formulations are demonstrated by estimating the risk-targeted seismic design action for a six-storey reinforced concrete building. By verifying the collapse risk of the designed structure, it is demonstrated that the risk-targeted seismic action, in conjunction with a conventional force-based design, provided structure with acceptable performance when measured in terms of collapse risk.  相似文献   

16.
An envelope‐based pushover analysis procedure is presented that assumes that the seismic demand for each response parameter is controlled by a predominant system failure mode that may vary according to the ground motion. To be able to simulate the most important system failure modes, several pushover analyses need to be performed, as in a modal pushover analysis procedure, whereas the total seismic demand is determined by enveloping the results associated with each pushover analysis. The demand for the most common system failure mode resulting from the ‘first‐mode’ pushover analysis is obtained by response history analysis for the equivalent ‘modal‐based’ SDOF model, whereas demand for other failure modes is based on the ‘failure‐based’ SDOF models. This makes the envelope‐based pushover analysis procedure equivalent to the N2 method provided that it involves only ‘first‐mode’ pushover analysis and response history analysis of the corresponding ‘modal‐based’ SDOF model. It is shown that the accuracy of the approximate 16th, 50th and 84th percentile response expressed in terms of IDA curves does not decrease with the height of the building or with the intensity of ground motion. This is because the estimates of the roof displacement and the maximum storey drift due to individual ground motions were predicted with a sufficient degree of accuracy for almost all the ground motions from the analysed sets. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
对《建筑工程抗震性态设计通则(试用)》的评述   总被引:4,自引:2,他引:4  
《建筑工程抗震性态设计通则(试用)》(以下简称《通则》)是一部对我国抗震设计规范修订具有重大指导意义的试用标准.本文对《通则》和现行规范的某些不同和改进之处进行了比较,讨论了《通则》所具有的先进性和行业指导性,同时也对应用《通则》的原理,对修订和完善下一代规范还需要研究的问题提出了若干建议.  相似文献   

18.
在基于性能抗震设计中,要求实现多级设防,目的是使结构抗震设计不仅要保护生命安全,同时也要控制因结构破坏而带来的经济损失,使结构在整个生命周期内费用达到最小。但由于结构抗震设计中存在着大量的不确定因素,使得实现每个性能水平都是不确定的,因此,每个性能水平的目标可靠度究竟取多高才能达到设计要求,是目前抗震设计的一个基本问题。针对这一问题,将地震作用、自重荷载、材料强度等看作随机变量,分析了结构造价与失效概率之间的近似关系,明确了不同性能水平失效概率之间的合理比例关系,采用"投资-效益"准则,且控制人员伤亡率小于社会可接受水平,来确定结构的目标性能水平。以两个钢筋混凝土框架结构为例,说明了该方法的应用。  相似文献   

19.
Usually, buildings with seismic isolation are designed to comply with an operational building performance level after strong earthquakes. This approach, however, may limit the use of seismic isolation for the seismic rehabilitation of existing buildings with low lateral strength or substandard details, because it often requires invasive strengthening measures in the superstructure or the use of expensive custom‐made devices. In this paper, an alternative approach for the seismic rehabilitation of existing buildings with seismic isolation, based on the acceptance of limited plastic deformations in the superstructure under strong earthquakes, is proposed and then applied to a real case study, represented by a four‐storey RC frame building. Nonlinear response‐time histories analyses of an accurate model of the case‐study building are carried out to evaluate the seismic performances of the structure, comparing different rehabilitation strategies with and without seismic isolation. Initial costs of the intervention and possible (future) repair costs are then estimated. Based on the results of this study, values of the behavior factor (i.e. response modification factor) higher than those adopted in the current codes for base‐isolated buildings are tentatively proposed. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
在基于性能的抗震设计中,为了使结构在整个生命周期内费用达到最小,不仅需要确定各个性能水平的目标失效概率,同时还需要确定不同性能水平目标失效概率之间的合理关系。本文针对这个问题。研究了在结构造价一定的情况下,不同性能水平失效概率的合理比例关系,使得在设计基准期内结构损失达到最小。在本文中,根据我国建筑抗震设计规范的条件,仅考虑“小震不坏”和“大震不倒”两个性能水平。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏