首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Universal time from VLBI single-baseline observations during CONT08
Authors:Tobias Nilsson  Johannes Böhm  Harald Schuh
Institution:1.Institute of Geodesy and Geophysics,Vienna University of Technology,Vienna,Austria
Abstract:The IVS Intensive sessions are single-baseline, 1-h VLBI sessions carried out everyday in order to determine Universal Time (UT1). We investigate different possibilities to improve the results of such sessions. We do this investigation by extracting 2-h single-baseline sessions from the CONT08 data set. These are analysed like normal Intensives, and the results are compared to the results of the analysis of the full CONT08 data set. We find that tropospheric asymmetry is the major error source for the single-baseline sessions. It is possible to improve the accuracy of the estimated UT1 either by using accurate a priori tropospheric gradients or by estimating gradients in the data analysis.
Keywords:
本文献已被 SpringerLink 等数据库收录!