新型平口式集沙仪对不同粒级颗粒的收集效率
引用本文:王仁德,李庆,常春平,郭中领.新型平口式集沙仪对不同粒级颗粒的收集效率[J].中国沙漠,2018,38(4):734-738.
作者姓名:王仁德  李庆  常春平  郭中领
作者单位:1. 河北省科学院 地理科学研究所/河北省地理信息开发应用工程技术研究中心, 河北 石家庄 050011;2. 河北师范大学 资源与环境科学学院/河北省环境演变与生态建设省级重点实验室, 河北 石家庄 050024
基金项目:国家自然科学基金项目(41630747,41330746,40110251)
摘    要:目前,国内缺少对集沙仪集沙效率问题的深入研究。采用风洞实验手段,就新型平口式集沙仪对不同粒级颗粒的收集效率进行了研究。结果表明:该集沙仪对1~0.85、0.85~0.5、0.5~0.25、0.5~0.1、0.25~0.1、0.1~0.05、<0.1、<0.05mm粒级颗粒的平均收集效率分别为54.9%、59.6%、69.7%、52.6%、24.6%、21.0%、17.7%、13.2%,表现出对>0.25mm粒级颗粒收集效率较高、对<0.25mm粒级颗粒收集效率较低的特点。该集沙仪的集沙效率不是随着颗粒粒级增大而一直增大的,而是在0.5mm左右存在一个峰值。集沙仪的集沙效率没有表现出随风速变化的明显规律性,与各粒级颗粒风蚀强度之间也没有必然的联系。造成集沙仪对不同粒级颗粒收集效率差距较大的原因可能是不同粒级颗粒运动状态的差异和沙网孔径的大小。

关 键 词:新型平口式集沙仪  集沙效率  不同粒级颗粒  
收稿时间:2017-07-04
修稿时间:2017-07-10

Sampling Efficiency of A New Flat Opening Collector for Particles with Various Sizes
Wang Rende,Li Qing,Chang Chunping,Guo Zhongling.Sampling Efficiency of A New Flat Opening Collector for Particles with Various Sizes[J].Journal of Desert Research,2018,38(4):734-738.
Authors:Wang Rende  Li Qing  Chang Chunping  Guo Zhongling
Institution:1. Institute of Geographical Sciences/Hebei Engineering Research Center for Geographic Information Application, Heibei Academy of Sciences, Shijiazhuang 050011, China;2. College of Resource and Environment Sciences/Hebei Key Laboratory of Environmental Change and Ecological Construction, Hebei Normal University, Shijiazhuang 050024, China
Abstract:There is a lack of knowledge on sampling efficiency of sand collector in China. The sampling efficiency of a new flat opening collector for particles with various sizes was calibrated by wind tunnel experiment in the paper. The results show that the average sampling efficiencies are 54.9%, 59.6%, 69.7%, 52.6%, 24.6%, 21.0%, 17.7%, 13.2% for 0.8-1.0, 0.5-0.8, 0.25-0.5, 0.1-0.5, 0.1-0.25, 0.05-0.1, <0.1, <0.05 mm sediment, respectively. Its sampling efficiency is high for > 0.25mm sediment (>50%) and low for < 0.25 mm sediment (<25%). Sampling efficiency of the collector cannot improve constantly with the particle sizes increasing, but has a peak at about 0.5 mm in diameter. There is not obviously changing regularity of sampling efficiency with wind speed increasing, and there is not essential connection between sampling efficiency and wind erosion intensity at all particle sizes. The large disparity in sampling efficiency for different sizes of particles is determined probably by the difference in transporting modes by wind due to different particle sizes and the aperture sizes of the filtering screen.
Keywords:new flat opening collector  sampling efficiency  particles with various sizes  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国沙漠》浏览原始摘要信息
点击此处可从《中国沙漠》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号