首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Estimation of concentration and exposure doses due to radon by using CR-39 plastic track detectors in the residences of Sudhnuti, Azad Kashmir, Pakistan
Authors:Muhammad Rafique  Saeed Ur Rahman  Muhammad Akram and Matiullah
Institution:(1) Department of Physics, University of Azad Jammu and Kashmir Muzaffarbad, 13100 Azad Kashmir, Pakistan;(2) Department of Medical Physics, Nuclear Medicine, Oncology and Radiotherapy Institute, Islamabad, Pakistan;(3) Physics Division, PINSTECH, P.O. Nilore, Islamabad, Pakistan
Abstract:This paper presents the results of indoor radon concentration measurements in 120 dwellings of district Sudhnuti of Azad Kashmir. Measurements were taken with CR-39 passive alpha track detector. CR-39 based box type radon detectors were installed in a bedroom and living rooms of each house. The detectors were retrieved after exposing to indoor radon for period of 6 months and then etched in 6 M NaOH at 80°C for 16 h, the observed track densities were converted in to the indoor radon concentration. Indoor radon concentration varied from 20 ± 12 to 170 ± 4 Bq m−3 for the houses of the district Sudhnuti. Arithmetic mean (AM), geometric mean (GM) and geometric standard deviations (GSD) were found to be 82 ± 6, 77 ± 6 and 1.51, respectively. The minimum value of weighted average radon concentration was recorded in one of the house of Mang town, whereas the maximum value was found in the Pattan Sher Khan region. Doses due to indoor radon exposure vary from 0.50 ± 0.31 to 4.28 ± 0.11 mSv year−1 AM, GM and GSD. of mean effective doses were found to be 2.06 ± 0.13, 1.95 ± 0.18 and 1.51, respectively. According to the recommendations made by the Health Protection Agency, UK (200 Bq m−3) all the houses surveyed are within the safe limits.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号