首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基体分离-电位滴定法测定高硫金属矿中的微量氯
引用本文:胡晓静,卢琪,姜莉,钟志光,仇薪越,聂东锐,王琦,张华一,曹凤梅.基体分离-电位滴定法测定高硫金属矿中的微量氯[J].岩矿测试,2010,29(1):80-82.
作者姓名:胡晓静  卢琪  姜莉  钟志光  仇薪越  聂东锐  王琦  张华一  曹凤梅
作者单位:辽宁出入境检验检疫局,辽宁,大连,116001
基金项目:辽宁检验检疫局科研项目资助 
摘    要:使用碳酸钠-氧化锌混合碱焙烧样品,将硫化物矿中的低价硫转化为硫酸盐或高价硫,过滤分离基体,采用电位滴定法测定硫化物矿(铜精矿、锌精矿、硫铁矿)中的微量氯,消除由于硫化银沉淀的产生对氯化银测定结果的干扰。通过电位突越,确定滴定终点,消除色度和浊度对滴定终点的影响。采用电极电位-浓度二次微商滴定曲线,计算滴定终点。对混合碱的选择及加入量、焙烧温度、溶液酸度、测定温度、滴定介质以及基体和共存元素的干扰进行了试验。方法精密度(RSD,n=9)均小于9%,回收率为94.1%~105.6%。

关 键 词:电位滴定法  基体分离  高硫金属矿(硫化物矿)  微量氯
收稿时间:2009/3/29 0:00:00
修稿时间:2009/7/28 0:00:00

Determination of Micro-amount of Chloride in Hing Sulfur-Metallic Ores by Matrix Separation-Potentiometric Titration
HU Xiao jing,LU Qi,JIANG Li,ZHONG Zhi guang,QIU Xin yue,NIE Dong rui,WANG Qi,ZHANG Hua yi and CAO Feng mei.Determination of Micro-amount of Chloride in Hing Sulfur-Metallic Ores by Matrix Separation-Potentiometric Titration[J].Rock and Mineral Analysis,2010,29(1):80-82.
Authors:HU Xiao jing  LU Qi  JIANG Li  ZHONG Zhi guang  QIU Xin yue  NIE Dong rui  WANG Qi  ZHANG Hua yi and CAO Feng mei
Institution:(Liaoning Entry-Exit Inspection and Quarantine Buerau,Dalian 116001,China)
Abstract:A method for the determination of trace chloride in sulphide ores by potentiometric titration was developed. S~(2-) was oxidized to S~(6+) by roasting the samples mixed with zinc oxide-sodium carbonate in order to eliminate the interference from Ag_2S precipitation on AgCl measurement. The influence from chromaticity and turbidity on the end point of titration was eliminated by confirming the end point of titration with the potential jump and using the second derivative potentiometric titration curve to calculate the titration end-point, which can avoid the problem from drawing the E-V curve or the ΔE/ΔV-V curve. Some important measurement parameters such as selection of mixed alkali and its dosage, roasting temperature, solution acidity, titration medium and the effects of sample matrix and coexisting elements on the measurements were studied. The recovery of the method was in the range of 94.1%~105.6% with precision of better than 6.83% RSD, 8.70% RSD and 7.53% RSD for iron ores, copper concentrates and zinc concentrates respectively. The method was sensitive, accurate and simple. And good results were achieved for the analysis of trace chloride in sulphide ores.
Keywords:potentiometric titration  matrix separation  high sulfur-metallic ore(sulphide ore)  micro-amount of chloride
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《岩矿测试》浏览原始摘要信息
点击此处可从《岩矿测试》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号