首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Optical and Electrical Observations of an Abnormal Triggered Lightning Event with two Upward Propagations
Authors:Dong Zheng  Yijun Zhang  Weitao Lu  Yang Zhang  Wansheng Dong  Shaodong Chen  Jianru Dan
Institution:4,5 1 Laboratory of Lightning Physics and Protection Engineering, Chinese Academy of Meteorological Sciences, Beijing 100081 2 State Key Laboratory of Severe Weather, Chinese Academy of Meteorological Sciences, Beijing 100081 3 Guangdong Lightning Protection Center, Guangzhou 510080 4 Conghua Meteorological Bureau, Conghua 510925 5 Guangzhou Field Experiment Site for Lightning Research and Testing, Conghua 510925
Abstract:This study investigates an abnormal artificially triggered lightning event that produced two positive upward propagations: one during the initial stage (i.e., the upward leader (UL)) and the other after a negative downward aborted leader (DAL). The triggered lightning was induced in a weak thunderstorm over the experiment site and did not produce a return stroke. All of the intra-cloud lightning around the experiment site produced positive changes in the electric field. The initial stage was a weak discharge process. A downward dart leader propagated along the channel produced by the first UL, ending at a height of approximately 453 m and forming a DAL. Under the influence of the DAL, the electric field at a point located 78 m from the rod experienced a steady reduction of about 6.8 kV m-1 over 5.24 ms prior to the initiation of a new upward channel (i.e., the second upward propagation (UP)). The second UP, which started approximately 4.1 ms after the termination of the DAL and propagated along the original channel, was triggered by the DAL and sustained for approximately 2.95 ms. Two distinct current pulses were superimposed on the current of the second UP. The first pulse, which was related to the sudden initiation of the second UP, was characterized by a more rapid increase and decrease and a larger peak value than the second pulse, which was related to the development of the second UP into the area affected by the DAL. The second UP contained both a similar-to-leader process and a following neutralization process. This study introduces a new type of triggering leader, in which a new upward discharge is triggered in an established channel by an aborted leader propagating along the same channel with opposite polarity and propagation direction.
Keywords:triggered lightning  aborted leader  high-speed camera  current
本文献已被 CNKI SpringerLink 等数据库收录!
点击此处可从《Acta Meteorologica Sinica》浏览原始摘要信息
点击此处可从《Acta Meteorologica Sinica》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号