首页 | 本学科首页   官方微博 | 高级检索  
     检索      

一次全省性强雷暴天气的地闪特征
引用本文:潘娅英,王亚云,钱吴刚,黄新晴,邓霞君.一次全省性强雷暴天气的地闪特征[J].气象科技,2010,38(4):432-436.
作者姓名:潘娅英  王亚云  钱吴刚  黄新晴  邓霞君
作者单位:1. 浙江省气象服务中心,杭州,310017
2. 浙江省气象信息网络中心,杭州,310017
3. 浙江省气象台,杭州,310017
4. 浙江省丽水市气象台,丽水,323000
摘    要:2009年6月26日浙江出现全省范围的雷暴天气,此次过程中出现的地闪频数是自2006年闪电定位系统建立以来出现最多的一次。利用闪电定位实测资料、加密雨量站雨量实况以及多普勒天气雷达产品,对这一过程的地闪特征进行了分析。结果表明:此次地闪以负地闪为主,负地闪广泛分布于25~55dBz雷电回波区域内,而正闪多出现在25~35dBz回波中;地闪多出现在回波发展和前进的一侧,且密集分布在回波的梯度最大处,强回波中心处地闪较少出现;在回波开始减弱到中心强度为35dBz左右的区域没有地闪发生。地闪频数与全省过程累积降水量有很好的相关性,地闪的出现及其频数的增加意味着影响某地的强对流风暴正在发展或正向本地移来,对于单站来说雨强峰值滞后于地闪频数峰值半个小时以上,对于全省累积降水量则提前1~2h。因此地闪资料可以作为强对流天气的短时强降水预报的预警依据。

关 键 词:全省性强雷暴  地闪分布  地闪频数  短时强降水
收稿时间:2009/8/14 0:00:00
修稿时间:2010/1/18 0:00:00

Characteristics of a Cloud to Ground Lightning Event during a Large Scale Strong Storm
Pan Yaying,Wang Yayun,Qian Wugang,Huang Xinqing and Den Xiajun.Characteristics of a Cloud to Ground Lightning Event during a Large Scale Strong Storm[J].Meteorological Science and Technology,2010,38(4):432-436.
Authors:Pan Yaying  Wang Yayun  Qian Wugang  Huang Xinqing and Den Xiajun
Institution:Pan Yaying Wang Yayun Qian Wugang Huang Xinqing Den Xiajun(1 Zhejiang Provincial Meteorological Service Center,2 Zhejiang Provinceial Meteorological Information and Network Center,3 Zhejiang Provincial Meteorological Office,Hangzhou 310007;4 Lishui Meteorological Buearu,Zhejiang Province,Lishui 323000)
Abstract:A whole-province range thunderstorm occurred in Zhejiang Province on 26 June 2009,and the occurrence frequency of cloud-to-ground lightning in this thunderstorm is the highest since the establishment of the lightning position system in 2006.By means of the observation data from the lightning position system,the intensive rainfall observation system,and Doppler radar,the characteristics of the cloud-to-ground lightning process are analyzed.The results indicate that lightning strokes were mainly negative;in the lightning echo image,negative strokes were mostly distributed in the area of 25 dBz to 55 dBz,and positive strokes were usually in the area of 25 dBz to 35 dBz;lightning strokes occurred mostly on the side of echo development or advancement,distributed around the area with maximum gradients,and there seldom appeared lightning strokes around a strong echo center;the frequency of cloud-to-ground lightning was correlated closely with the accumulated precipitation of the whole province during the thunderstorm.The peak value of precipitation lagged more than 0.5 hour behind the peak value of the frequency of cloud-to-ground lightning,and the accumulated precipitation of the whole province occurred 1 to 2 hours behind the peak value of the frequency of cloud-to-ground lightning.Therefore,the cloud-to-ground lightning data can be used as a basis in short-range severe precipitation forecasting.
Keywords:large-scale thunderstorm  cloud-to-ground lightning distribution  frequency  short-range severe precipitation
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《气象科技》浏览原始摘要信息
点击此处可从《气象科技》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号