首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Prospects of hard X-ray polarimetry with Astrosat-CZTI
Authors:T Chattopadhyay  S V Vadawale  A R Rao  S Sreekumar  D Bhattacharya
Institution:1. Astronomy and Astrophysics Division, Physical Research Laboratory, Ahmedabad, India
2. Department of Astronomy and Astrophysics, Tata Institute of Fundamental Research, Mumbai, India
3. Baseband Systems Electronics Division, Vikram Sarabhai Space Centre, Thiruvananthapuram, India
4. The Inter-University Centre for Astronomy and Astrophysics, Pune, India
Abstract:Astrosat is the first Indian satellite mission dedicated for astronomical studies. It is planned for launch during 2014 and will have five instruments for multi-wavelength observations from optical to hard X-rays. Cadmium Zing Telluride Imager (CZTI) is one of the five instruments aiming for simultaneous X-ray spectroscopy and imaging in the energy range of 10 keV to 100 keV (along with all sky photometric capability unto 250 keV). It is based on pixilated CZT detector array with total geometric area of 1024 cm2. It will have two-dimensional coded mask for medium resolution X-ray imaging. The CZT detector plane will be realized using CZT detector modules having integrated readout electronics. Each CZT detector module consists of 4 cm × 4 cm CZT with thickness of 5 mm which is further pixilated into 16 × 16 array of pixels. Thus each pixel has size of 2.5 mm × 2.5 mm and thickness of 5 mm. Such pixilated detector plane can in principle be used for hard X-ray polarization measurements based on the principle of Compton scattering by measuring azimuthal distribution of simultaneous events in two adjacent pixels. We have carried out detailed Geant4 simulations for estimating polarimetric capabilities of CZTI detector plane. The results indicate that events in the energy range of 100 keV to 250 keV, where the 5 mm thick CZT detector has significant detection efficiency, can be used for polarimetric studies. Our simulation results indicate the minimum detectable polarization (MDP) at the level of ~ 10% can be achieved for bright Crab like X-ray sources with exposure time of ~500 ks. We also carried out preliminary experiments to verify the results from our simulations. Here we present detailed method and results of our simulations as well as preliminary results from the experimental verification of polarimetric capabilities of CZT detector modules used in Astrosat CZTI.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号