首页 | 本学科首页   官方微博 | 高级检索  
     检索      

高浓度造影剂在眼动脉CT双能量血管成像中的应用研究
引用本文:曹伟,刘洪,王帆,黄海东.高浓度造影剂在眼动脉CT双能量血管成像中的应用研究[J].CT理论与应用研究,2016,25(6):633-638.
作者姓名:曹伟  刘洪  王帆  黄海东
作者单位:江苏省徐州市第一人民医院, 江苏 徐州 221000
摘    要:目的:探讨双源螺旋CT双能量血管成像配合高浓度碘造影剂在眼动脉血管成像中的应用价值。方法:2014年3月至2015年12月选择在我院行颅脑CTA患者80例(160眼),随机分成观察组与对照组两组,两组分别行双能CT血管造影及螺旋CT减影成像后判断与分析。前者使用拜耳370mg I/m L造影剂,后者使用GE 350mg I/m L造影剂;结果:所有入选者的眼动脉CTA图像均明确显示,眼动脉主要分支血管充盈良好;经过测定,观察组的颅内段、视神经管段、眶内段等眼动脉直径都明显多于对照组(P<0.05),直径分别为1.26 mm±0.16 mm、1.21 mm±0.18 mm、1.12 mm±0.14 mm;观察组与对照组的斑块检出率分别为28.8%和2.5%,观察组明显高于对照组(P<0.05)。结论:利用双源螺旋CT行双能CT血管成像在眼动脉疾病判断的应用显示效果佳,能有效判断眼动脉直径状况与斑块情况,从而指导治疗。 

关 键 词:双源螺旋CT    双能血管成像    眼动脉    眼动脉斑块
收稿时间:2016-05-24

Application of CT Dual Energy Imaging with High Concentration Contrast in Ophthalmic Artery Vascular Examination
CAO Wei,LIU Hong,WANG Fan,HUANG Hai-dong.Application of CT Dual Energy Imaging with High Concentration Contrast in Ophthalmic Artery Vascular Examination[J].Computerized Tomography Theory and Applications,2016,25(6):633-638.
Authors:CAO Wei  LIU Hong  WANG Fan  HUANG Hai-dong
Institution:Department of Radiology, the First Peoples Hospital of Xuzhou, Xuzhou 221002, China
Abstract:Objective: To explore the application value of iodine contrast agent with high concentration in the ophthalmic artery angiography in dual source dual energy CT angiography. Methods: From March 2014 to December 2015, 80 patients(160 eyes) with brain CTA were selected in our hospital. 80 patients were randomly divided into observation group and control groups, Judgment and analysis of the two groups of dual energy CT angiography and spiral CT subtraction, the former uses the Bayer 370 mg I/m L contrast agent, the latter uses the GE 350 mg I/m L contrast agent. Results: The ophthalmic artery CT angiography images of all subjects showed clear, full of each vessel filling well. After the measurement, the intracranial segment of the observation group, the optic nerve canal segment, the diameter of the orbital segment and other ocular artery were significantly more than the control group(P<0.05), Diameter(mm) were: 1.26 ±0.16, 1.21 ±0.18, 1.12 ±0.14. The detection rate of plaque in the observation group and the control group were 28.8% and 2.5%, the observation group was significantly higher than that of the control group(P<0.05). Conclusion: Using dual source spiral CT dual energy CT angiography applied in the judgment of the ophthalmic artery disease showed good effect. Can effectively judge the diameter of the ophthalmic artery and plaque situation, so as to guide the treatment. 
Keywords:dual source CT  dual energy imaging  ophthalmic artery  ophthalmic artery plaque
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《CT理论与应用研究》浏览原始摘要信息
点击此处可从《CT理论与应用研究》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号