首页 | 本学科首页   官方微博 | 高级检索  
     检索      

钢-聚乙烯醇混杂纤维混凝土剪力墙抗震性能试验研究
引用本文:周颖,钟光淳,肖意.钢-聚乙烯醇混杂纤维混凝土剪力墙抗震性能试验研究[J].世界地震工程,2021,0(1):011-25.
作者姓名:周颖  钟光淳  肖意
作者单位:同济大学 土木工程防灾国家重点实验室,上海 200092
摘    要:本文设计了1片普通混凝土剪力墙试件和5片混杂纤维混凝土剪力墙试件,进行低周往复加载试验,研究混杂纤维混凝土分布位置和高度对剪力墙抗震性能的影响。根据拟静力试验数据,分析了墙体试件的滞回曲线、骨架曲线及关键点、位移延性、刚度退化性能、耗能能力以及关键位置钢筋应力应变分布情况。结果表明:(1)剪力墙试件中采用混杂纤维混凝土的区域以均匀的水平裂缝为主,有效控制了剪力墙的斜裂缝的产生,最终表现出弯曲破坏模式。(2)相比混杂纤维混凝土分布在约束边缘区域,混杂纤维混凝土分布在底部的试件滞回曲线更加饱满,耗能能力更好。(3)混杂纤维混凝土分布高度越高,滞回曲线越饱满。当分布高度大于0.3h (h为全长)时,混杂纤维混凝土分布高度的提升对承载能力和变形能力的影响较小。(4)混杂纤维混凝土的掺入提高了剪力墙的抗剪性能,在一定程度上可替代水平分布筋。

关 键 词:钢-聚乙烯醇混杂纤维混凝土  剪力墙  低周往复加载  分布位置  抗震性能

Experimental study on the seismic behavior of steel-polyviny alcohol hybrid fiber reinforced concrete shear walls
ZHOU Ying,ZHONG Guangchun,XIAO Yi.Experimental study on the seismic behavior of steel-polyviny alcohol hybrid fiber reinforced concrete shear walls[J].World Information On Earthquake Engineering,2021,0(1):011-25.
Authors:ZHOU Ying  ZHONG Guangchun  XIAO Yi
Institution:State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, China
Abstract:In order to conduct research on the seismic behavior of hybrid fiber reinforced concrete (HyFRC) shear walls, one ordinary concrete shear wall and five HyFRC shear wall specimens were designed, and the quasi-static tests were carried out. The hysteretic curves, skeleton curves, displacement ductility, stiffness degradations, energy dissipation capacities and stress-strain behaviors of steel bars in key position of shear wall specimens were investigated. The results shows that:(1) The HyFRC region in shear wall holds horizontal cracks and control the production of shear cracks. The final failure model is flexural failure. (2) Compared with the specimen with HyFRC distributed in boundary elements, the specimens with HyFRC distributed in bottom area have fuller hysteretic curve and stronger energy dissipation capacity. (3) The higher the distribution height of HyFRC is, the fuller the hysteretic curve is. When the distribution height is more than 0.3 h (h is the full length of shear wall), the increase of the distribution height of HyFRC has little effect on the bearing capacity and deformation capacity of shear walls. (4) The incorporation of HyFRC improves the shear resistance of shear wall and can replace the horizontal distributed reinforcements to a certain extent.
Keywords:steel-PVA hybrid fiber reinforced concrete  shear wall  quasi-static test  distribution location  seismic performance
本文献已被 CNKI 等数据库收录!
点击此处可从《世界地震工程》浏览原始摘要信息
点击此处可从《世界地震工程》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号