首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Measurement of partition coefficients of phenol and cresols in gas-charged crude oil/water systems
Authors:B Bennett  A C Aplin  S R Larter
Institution:NRG, School of Civil Engineering and Geosciences, Drummond Building, The University, Newcastle upon Tyne, NE1 7RU, UK
Abstract:An instrument has been constructed for monitoring the partition coefficients of phenol and cresols between crude oil and water under sub-surface conditions. The device has the capacity for introducing methane gas into crude oil, thereby allowing measurements under live oil (solution gas-containing) conditions. The partition coefficients of phenol and cresols have been measured in crude oil: water substrates under “live” oil and “dead” oil (without solution gas) conditions over a temperature range 25–150 °C. Over the range investigated it is seen that the introduction of gas (crude oil saturated at 100 bar with methane) into the system resulted in an approximate doubling of partition coefficients compared to the equivalent dead oil: brine systems. The partition coefficient data obtained using the device may be employed in a number of petroleum exploration and production activities such as the determination of residual oil saturation of a water-flooded petroleum reservoir. Partition coefficient measurements may help in predicting toxic organic solute loadings in oilfield discharge waters.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号