石墨炉原子吸收光谱法测定味精中痕量铅的不确定度评定
引用本文:王玉功,李国兵,拉毛吉,王建波.石墨炉原子吸收光谱法测定味精中痕量铅的不确定度评定[J].岩矿测试,2009,28(2):165-168.
作者姓名:王玉功  李国兵  拉毛吉  王建波
作者单位:1. 国土资源部兰州矿产资源监督检验中心,甘肃,兰州,730050
2. 湖南省地球物理地球化学勘查研究所,湖南,邵阳,422002
摘    要:以石墨炉原子吸收光谱法测定味精中痕量铅为例,对测定结果的不确定度来源进行分析,对测定过程的主要不确定度分量进行合理评定,包括称量不确定度、体积不确定度、曲线拟合不确定度及测量重复性引入的不确定度。评估了铅含量的合成标准不确定度和扩展不确定度。对于铅含量为0.025×10-6的味精样品,其扩展不确定度为0.002×10-6。

关 键 词:不确定度评定  石墨炉原子吸收光谱法  痕量铅  味精
收稿时间:2008/6/10 0:00:00
修稿时间:2008/8/20 0:00:00

Uncertainty Evaluation of Determination Results for Trace Lead in Monosodium Glutamate by Graphite Furnace Atomic Absorption Spectrometry
WANG Yu-gong,LI Guo-bing,LA Mao-ji and WANG Jian-bo.Uncertainty Evaluation of Determination Results for Trace Lead in Monosodium Glutamate by Graphite Furnace Atomic Absorption Spectrometry[J].Rock and Mineral Analysis,2009,28(2):165-168.
Authors:WANG Yu-gong  LI Guo-bing  LA Mao-ji and WANG Jian-bo
Institution:1(1.Lanzhou Testing and Quality Supervision Center for Geological and Mineral Products, The Ministry of Land and Resources,Lanzhou 730050,China;2.Institute of Geophysical and Geochemical Exploration,Shaoyang 422002,China)
Abstract:The uncertainty measurement of the trace Pb in monosodium glutamate samples by graphite furnace atomic absorption spectrometry(GFAAS) was evaluated in this paper.The results showed that the main sources of the total uncertainty came from the fraction uncertainties of sample weighting,calibration curve fitting,the certified values of standard reference materials,the instrument stability and etc..The total uncertainty for the determination of lead by GFAAS was combined and the expanding uncertainty was calculated with value of 0.002×10-6 for the monosodium glutamate sample with lead content of 0.025×10-6.
Keywords:uncertainty evaluation  graphite furnace atomic absorption spectrometry  trace lead  monosodium glutamate