首页 | 本学科首页   官方微博 | 高级检索  
     检索      


EMC design for actuators in the FAST reflector
Authors:Hai-Yan Zhang  Ming-Chang Wu  You-Ling Yue  Heng-Qian Gan  Hao Hu  Shi-Jie Huang
Abstract:An active reflector is one of the three main innovations incorporated in the Five-hundredmeter Aperture Spherical radio Telescope(FAST).The deformation of such a huge spherically shaped reflector into different transient parabolic shapes is achieved by using 2225 hydraulic actuators which change the position of the 2225 nodes through the connected down tied cables.For each different tracking process of the telescope,more than 1/3 of these 2225 actuators must be in operation to tune the parabolic aperture accurately and meet the surface error restriction.This means that some of these actuators are inevitably located within the main beam of the receiver,and Electromagnetic Interference(EMI)from the actuators must be mitigated to ensure the scientific output of the telescope.Based on the threshold level of interference detrimental to radio astronomy described in ITU-R Recommendation RA.769 and EMI measurements,the shielding efficiency(SE)requirement for each actuator is set to be 80 d B in the frequency range from 70 MHz to 3 GHz.Therefore,Electromagnetic Compatibility(EMC)was taken into account in the actuator design by measures such as power line filters,optical fibers,shielding enclosures and other structural measures.In 2015,all the actuators had been installed at the FAST site.Till now,no apparent EMI from the actuators has been detected by the receiver,which demonstrates the effectiveness of these EMC measures.
Keywords:
本文献已被 CNKI 等数据库收录!