Abstract: | A series of studies was conducted on three buildings of steel reinforced concrete structures with RC shear walls damaged in the 1995 Hyogo-ken Nanbu earthquake. These buildings are located in an area where structural damage centred around. Two of these buildings suffered severe damage, while the third was not structurally damaged. Our studies deal with site inspections, including micro-tremor measurement of buildings, the evaluation of input motions, and the response analyses considering soil–structure interaction. The results of simulation analyses of the two severely damaged buildings correspond to their actual damage state. From the response analyses of the one slender building with no structural damage, it was concluded that uplifting is the main reason it did not suffer any structural damage. Through these studies, the importance of soil–structure interaction and effective input motion is fully understood. Copyright © 1999 John Wiley & Sons, Ltd. |