北京五里营水温干扰分析及解决
引用本文:武晓东,王志惠,朱石军. 北京五里营水温干扰分析及解决[J]. 大地测量与地球动力学, 2012, 32(Z1): 96-97
作者姓名:武晓东  王志惠  朱石军
作者单位:北京市地震局延庆地震台,北京,102100
摘    要:北京五里营井水温每天都有24次锯齿状畸变,有很好的规律性,经分析认为是气氡观测对水温造成影响.将气氡和水温供电分离,并在水温地线和地网之间增加一个电感,以阻挡其他干扰信号由地线反馈到观测仪器,改造后水温脉冲干扰彻底消除,观测质量明显提高.

关 键 词:五里营井  水温异常  畸变  负载变化  气氡观测

ANALYSIS AND SOLUTION FOR DISTURBENCE OF WATER TEMPERATURE IN WULIYING WELL
Wu Xiaodong , Wang Zhihui , Zhu Shijun. ANALYSIS AND SOLUTION FOR DISTURBENCE OF WATER TEMPERATURE IN WULIYING WELL[J]. Journal of Geodesy and Geodynamics, 2012, 32(Z1): 96-97
Authors:Wu Xiaodong    Wang Zhihui    Zhu Shijun
Affiliation:(Yanqing Seismostation of Earthquake Administration of Beijing Municipal,Beijing 102100)
Abstract:We found the minute-value observing curve of the water temperature at Wuliying station in Beijing showed 24 sawtooth figures ordinarily,and confirmed that was caused by the radon observation.We separated the radon and the electric supply for the water temperature and added an inductor between the earth wire and earth mat to cut the other jamping signals from the earth wire to the observing instrument.After the transformation,the pulse jamping of the water temperature disappeared completly and the observing quality made much improvement.
Keywords:water well at Wuliying  anomaly of water temperature  distortion  load fluctuation  radon observation