Seismic bearing capacity of shallow strip footings |
| |
Authors: | Deepankar?Choudhury mailto:dc@civil.iitb.ac.in" title=" dc@civil.iitb.ac.in" itemprop=" email" data-track=" click" data-track-action=" Email author" data-track-label=" " >Email author,Kanakapura?S.?Subba Rao |
| |
Affiliation: | (1) Department of Civil Engineering, Indian Institute of Technology Bombay, Powai, Mumbai, 400 076, India;(2) Department of Civil Engineering, Indian Institute of Science, Bangalore, 560 012, India |
| |
Abstract: | ![]() Seismic bearing capacity of shallow strip footings in soil has been obtained in the form of pseudo-static seismic bearing capacity factors Ncd, Nqd and N d, denoting the cohesion, surcharge and unit weight components, respectively, by an extensive numerical iteration technique. Limit equilibrium method of analysis with composite failure surface is assumed. The validity of the principle of superposition is examined. Effects of both the horizontal and vertical seismic acceleration coefficients have been found to always reduce the ultimate bearing capacity significantly. Results obtained by the present method of analysis are compared with the available results and are found to be the least in the seismic case. |
| |
Keywords: | limit equilibrium pseudo-static seismic bearing capacity shallow strip footings |
本文献已被 SpringerLink 等数据库收录! |
|