摘    要:以电加热器作为热源的热响应测试仪,仅能进行夏季制冷工况测试,参数设定以经验为主。应用了以热泵作为冷/热源、可测试冬季供暖工况的原位热响应测试仪进行测试实验,结果表明:热泵输出功率稳定,测试功率在夏季制冷工况和冬季供暖工况宜分别设为40~60 W/m和35~45 W/m;热响应测试时间不宜少于48 h,若模型精度要求高于2.5%,需根据地层情况适当延长测试时间;野外测试的冬季供暖工况下热交换孔的热阻为0.08(m.℃)/W,100 m深度内岩土体的综合导热系数为1.67 W/(m.℃)。测试结果可满足地源热泵系统设计要求。

关 键 词:热响应  原位测试  温度控制  地源热泵

In-Situ Thermal Response Test Methods and Experiment for Design of Ground Source Heat Pump System
Lü Peng,Sun You-hong,Wang Qing-hua,Wu Xiao-han.In-Situ Thermal Response Test Methods and Experiment for Design of Ground Source Heat Pump System[J].Journal of Jilin Unviersity:Earth Science Edition,2012(Z1):362-366.
Authors:Lü Peng  Sun You-hong  Wang Qing-hua  Wu Xiao-han
Institution:1.College of Construction Engineering,Jilin University,Changchun 130026,China 2.Changchun University of Science and Technology,Changchun 130022,China 3.AVIC Geotechnical Engineering Institute Co.,LTD,Beijing 100098,China
Abstract:The thermal response test equipment with electric heat source merely test the refrigeration condition,and the test parameters was set by experience.Heat pump source thermal response test equipment can test both of the refrigeration condition and the thermal condition,the test result of this equipment showed that the output power of heat pump was stable under the T tube valve control.And the test power should be defined as 40-60 W/m in refrigeration condition and 35-45 W/m in heating condition.Test time should not be less than 48 hours and should be extended when the was less than 2.5%.Filed validation showed that thermal resistance of heat exchanging role was 0.08(m·℃)/W,and the comprehensive thermal conductivity of 100 m depth stratum was 1.67 W/(m·℃) in heating condition,which can meet the needs of ground source heat pump system.
Keywords:thermal response testing  in-situ test  temperature control  ground source heat pump
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号