首页 | 本学科首页   官方微博 | 高级检索  
     检索      

微波溶样-自动电位滴定法测定铬矿石中三氧化二铬
引用本文:胡德新,马德起,苏明跃,王虹,姚传刚.微波溶样-自动电位滴定法测定铬矿石中三氧化二铬[J].岩矿测试,2011,30(1):83-86.
作者姓名:胡德新  马德起  苏明跃  王虹  姚传刚
作者单位:天津出入境检验检疫局化矿金检测中心,天津,300456
摘    要:样品经硫酸-磷酸-氟硼酸分解,在30~60 kPa条件下进行微波溶样,用自动电位滴定仪测定铬矿石中三氧化二铬的含量。对两个不同三氧化二铬含量的铬矿石国家一级标准物质测定20次,测定的平均值与标准值的相对误差为0.015%~0.021%,相对标准偏差为0.09%~0.10%。选取主要进口国的不同含量的铬矿石进行主含量的测定,与经典法对比,分析结果均在合理允差范围之内。方法具有简便、快速、低耗、污染小等优点,可应用于大批铬矿石样品的分析及检测。

关 键 词:三氧化二铬  铬矿石  自动电位滴定法  微波消解
收稿时间:2010/5/10 0:00:00
修稿时间:2010/8/20 0:00:00

Determination of Chromium Oxide in Chrome Ores by Automatic Potentiometric Titrimetry with Microwave Digestion Sample Preparation
HU De-xin,MA De-qi,SU Ming-yue,WANG Hong and YAO Chuan-gang.Determination of Chromium Oxide in Chrome Ores by Automatic Potentiometric Titrimetry with Microwave Digestion Sample Preparation[J].Rock and Mineral Analysis,2011,30(1):83-86.
Authors:HU De-xin  MA De-qi  SU Ming-yue  WANG Hong and YAO Chuan-gang
Institution:Minerals and Metallic Materials Inspection Center of Tianjin Entry-Exit Inspection and Quarantine Bureau, Tianjin 300456, China;Minerals and Metallic Materials Inspection Center of Tianjin Entry-Exit Inspection and Quarantine Bureau, Tianjin 300456, China;Minerals and Metallic Materials Inspection Center of Tianjin Entry-Exit Inspection and Quarantine Bureau, Tianjin 300456, China;Minerals and Metallic Materials Inspection Center of Tianjin Entry-Exit Inspection and Quarantine Bureau, Tianjin 300456, China;Minerals and Metallic Materials Inspection Center of Tianjin Entry-Exit Inspection and Quarantine Bureau, Tianjin 300456, China
Abstract:A method for the determination of Cr2O3 in chrome ores by automatic potentiometric titrimetry technology coupled with microwave digestion under high-pressure was developed.The method has been tested by determination of Cr2O3 in 2 National Standard Reference chrome ore samples with wide range of Cr2O3 contents.The results were in agreement with certified values with relative error of 0.015%~0.021% and the precision of 0.089%~0.102% RSD(n=20).Six imported inspection samples were also tested by the method and the results were in accordance with those from classical method.The method provides the advantages of low energy consumption,low labor intensity,high efficiency and is suitable for the daily inspection work.
Keywords:chromium oxide  chrome ore  automatic potentiometric titrimetry  microwave digestion
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《岩矿测试》浏览原始摘要信息
点击此处可从《岩矿测试》下载免费的PDF全文