首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Retrofit of reinforced concrete frames with buckling‐restrained braces
Authors:Christoph Mahrenholtz  Pao‐Chun Lin  An‐Chien Wu  Keh‐Chyuan Tsai  Shyh‐Jiann Hwang  Ruei‐Yan Lin  Muhammad Y Bhayusukma
Institution:1. Department of Civil Engineering, National Taiwan University, Taipei, Taiwan;2. National Center for Research in Earthquake Engineering, Taipei, Taiwan
Abstract:Damage to buildings observed in recent earthquakes suggests that many old reinforced concrete structures may be vulnerable to the effects of severe earthquakes. One suitable seismic retrofit solution is the installation of steel braces to increase the strength and ductility of a building. Steel bracings have some compelling advantages such as their comparatively low weight, their suitability for prefabrication, and the possibility of openings for utilities, access, and light. The braces are typically connected to steel frames that are fixed to the concrete structure using post‐installed concrete anchors along the perimeter. However, these framed steel braces are not without some disadvantages such as heavier steel usage and greater difficulties during the installation. Therefore, braces without steel frames appear to be an attractive alternative. In this study, braces were connected to gussets furnished with anchor brackets, which were fixed by means of a few post‐installed concrete anchors. The clear structural system and the increased utilization of the anchors allowed the anchorage to be designed precisely and economically. The use of buckling‐restrained braces (BRBs) provides additional benefits in comparison with conventional braces. BRBs improve the energy dissipation efficiency and allow the limitation of the brace force to be taken up by the highly stressed anchorage. Cyclic loading tests were conducted to investigate the seismic performance of BRBs connected with post‐installed anchors used to retrofit reinforced concrete frames. The tests showed that the proposed design method is feasible and increases strength as well as ductility to an adequate seismic performance level. Copyright © 2014 John Wiley & Sons, Ltd.
Keywords:seismic retrofit  post‐installed anchor  buckling‐restrained brace  concrete frame  composite structure  cyclic loading test
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号