首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Glide systems of hematite single crystals in deformation experiments
Authors:H Siemes  B Klingenberg  E Rybacki  M Naumann  W Schfer  E Jansen  K Kunze
Institution:aInstitut für Mineralogie und Lagerstättenlehre, RWTH Aachen, D-52056 Aachen, Germany;bGeoforschungszentrum Potsdam, Telegrafenberg, D-14473 Potsdam, Germany;cMineralogisches Institut Bonn, Forschungszentrum Jülich, D-52425 Jülich, Germany;dGeologisches Institut ETH Zürich, CH-8092 Zürich, Switzerland
Abstract:The critical resolved shear stresses (CRSSs) of hematite crystals were determined in compression tests for r-twinning, c-twinning and {a}<m>-slip in the temperature range 25 °C to 400 °C, at 400 MPa confining pressure, and a strain rate of 10− 5 s− 1 by Hennig-Michaeli, Ch., Siemes, H., 1982. Experimental deformation of hematile crstals betwen 25 °C and 400 °C at 400 MPa confining pressure. In: Schreyer, W. (Ed.) High Pressure Research in Geoscience, Schweizerbart'sche Verlagsbuchhandlung, Stuttgart, p. 133–150. In the present contribution newly performed experiments on hematite single crystals at temperatures up to 800 °C at strain rates of 10− 5 s− 1 and 300 MPa confining pressure extends the knowledge about the CRSS of twin and slip modes. Optical observations, neutron diffraction goniometry, SEM forescatter electron images and electron backscatter diffraction are applied in order to identify the glide modes. Both twinning systems and {a}<m>-slip were confirmed by these methods. Besides the known glide systems the existence of the (c)<a>-slip system could be stated. Mechanical data establish that the CRSS of r-twinning decreases from 140 MPa at 25 °C to not, vert, similar 5 MPa at 800 °C and for {a}<m>-slip from > 560 MPa at 25 °C to not, vert, similar 40 MPa at 700 °C. At room temperature the CRSS for c-twinning is around 90 MPa and at 600 °C not, vert, similar 60 MPa. The data indicate that the CRSSs above 200 °C seem to be between the values for r-twinning and {a}<m>-slip. For (c)<a>-slip only the CRSS at 600 °C could be evaluated to not, vert, similar 60 MPa. Exact values are difficult to determine because other glide systems are always simultaneously activated.
Keywords:Hematite single crystals  Experimental deformation  Slip modes  Twinning modes  Critical resolved shear stresses  Polarized light microscopy  Infrared microscopy  Neutron diffraction goniometry  Electron backscatter diffraction
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号