首页 | 本学科首页   官方微博 | 高级检索  
     检索      

P507负载泡塑分离ICPMs测定地质样品中的痕量银
引用本文:高玉花,毕建玲,殷学博.P507负载泡塑分离ICPMs测定地质样品中的痕量银[J].山东国土资源,2015,31(12).
作者姓名:高玉花  毕建玲  殷学博
作者单位:山东省物化探勘查院;山东省物化探勘查院;中国科学院海洋研究所
摘    要:结合前人研究工作,利用P507可有效分离银ICPMS测定的Zr,Nb等干扰元素,对P507负载泡塑分离ICPMs测定地质样品中的痕量银进一步验证讨论,以便该方法在行业内领域得以广泛应用,促进行业内地质样品中Ag及微量元素测试的效率与测试技术的提高,实现地质样品中痕量银及微量元素ICPMS同步快速准确分析。

关 键 词:P507ICPMs  痕量Ag  地质样品

Determination of Trace Ag in Geological Samples by Using P507to Separate ICP-MS Loaded Polyfoam
GAO Yuhu,BI Jianling and YIN Xuebo.Determination of Trace Ag in Geological Samples by Using P507to Separate ICP-MS Loaded Polyfoam[J].Land and Resources in SHANDONG Province,2015,31(12).
Authors:GAO Yuhu  BI Jianling and YIN Xuebo
Abstract:Combining with previous research work, by using P507, interference elements, such as Zr and Nb can be effectively separated in silver ICP-MS determination. The method for determing trace silver in the geological samples by using P507separation of loaded polyfoam has been further verified and discussed. Thus, it can be widely used in the industry field, promote testing efficiency and testing technology of Ag and trace elements in geological samples, and realize fast and accurate analysis of trace silver and trace element ICP-MS in geological samples.
Keywords:P507 ICP-MS  trace Ag  geological samples