首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Influence of transducer-ground coupling on vibration measurements
Authors:G R Adhikari  A I Theresraj  R N Gupta
Institution:  a National Institute of Rock Mechanics, PO Champion Reefs, KGF, India
Abstract:Various methods of transducer mounting provide varying degrees of coupling between the transducer and the measurement surface. The influence of four of these methods on vibration measurements was studied. For this purpose, the first transducer was placed freely on a horizontal surface, the second one was 'sandbagged', the third one was 'spiked' and the fourth one was completely buried in soil. These transducers were mounted side by side and ground vibrations were monitored for 14 blasts at an opencast coal mine.

Ground vibrations in terms of peak particle velocity, peak vector sum and frequency with different mounting methods were analysed. Assuming the data of the buried transducer as the most acceptable one, relative values of other transducers were determined and plotted. For the given tolerance for instrumental and human errors, anomalous readings were found in some cases. The waveforms of the buried transducer were then compared with those of others. Clear distortion in the waveforms or a very low correlation coefficient between two waveforms was suspected poor coupling.

The results indicate that decoupling is most likely with the surface transducer. However, the sandbagged and spiked transducers are also prone to decoupling. Decoupling can result in higher or lower ground vibration. Therefore, burial should be the preferred method for mounting of transducers in soil.
Keywords:Transducer-ground coupling  Transducer mounting  Ground vibration monitoring
本文献已被 InformaWorld 等数据库收录!