首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Non-Simultaneous Failure of Ice in Front of Multi-Leg Structures
作者姓名:SHI  Qingzeng
作者单位:School of Civil Engineering,Tianjin University,School of Civil Engineering,Tianjin University,School of Civil Engineering,Tianjin University,School of Civil Engineering,Tianjin University Tianjin 300072,China,Tianjin 300072,China,Tianjin 300072,China,Tianjin 300072,China
摘    要:Because the multi-leg jacket structure is the major type of offshore structures in the Bohai Sea, the study of non-si-multaneous failure of i鏴 on multi-leg structures is important. However, the non-simultaneous failure has not been consid-ered in engineering design until now, obviously resulting in costly design and notable waste. To resolve this problem, this paper, by means of analysis of experimental data, calculates the coefficient of the non-simultaneous failure for the double-pile structure, the square four-leg structure, the single-line multi-pile structure, and the conical structure, respectively, and provides some reference criteria for engineering design.


Non-Simultaneous Failure of Ice in Front of Multi-Leg Structures
SHI Qingzeng HUANG Yan SONG An and TONG Jianfeng School of Civil Engineering,Tianjin University,Tianjin ,China.Non-Simultaneous Failure of Ice in Front of Multi-Leg Structures[J].China Ocean Engineering,2002,16(2):183-192.
Authors:SHI Qingzeng HUANG Yan SONG An and TONG Jianfeng School of Civil Engineering  Tianjin University  Tianjin  China
Institution:School of Civil Engineering, Tianjin University, Tianjin 300072, China School of Civil Engineering, Tianjin University, Tianjin 300072, China School of Civil Engineering, Tianjin University, Tianjin 300072, China School of Civil Engineering, Tianjin University, Tianjin 300072, China
Abstract:Because the multi-leg jacket structure is the major type of offshore structures in the Bohai Sea, the study of non-si-multaneous failure of ice on multi-leg structures is important. However, the non-simultaneous failure has not been consid-ered in engineering design until now, obviously resulting in costly design and notable waste. To resolve this problem, thispaper, by means of analysis of experimental data, calculates the coefficient of the non-simultaneous failure for the double-pile structure, the square four-leg structure, the single-line multi-pile structure, and the conical structure, respectively,and provides some reference criteria for engineering design.
Keywords:multi-leg structure  pile  cone  ice force  non-simutaneous failure of ice  coefficient of non-simultaneous failure af ice
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国海洋工程》浏览原始摘要信息
点击此处可从《中国海洋工程》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏