极端气象条件诱发的静电火灾事故分析与防范建议
引用本文:李家启,李黎,黄亚敏,秦健,曾理.极端气象条件诱发的静电火灾事故分析与防范建议[J].气象科技,2012,40(2):310-314.
作者姓名:李家启  李黎  黄亚敏  秦健  曾理
作者单位:1. 南京信息工程大学,南京210044;重庆市北碚区气象局,重庆400700
2. 重庆市防雷中心,重庆,401147
3. 重庆市北碚区气象局,重庆,400700
基金项目:中国气象局 2010年软科学课题“应急抢险救援防雷安全技术研究”、重庆市气象局“雷电灾害物理鉴定方法研究”项目资助
摘    要:针对重庆一家制药厂2006年9月3日22:00发生的一起火灾,利用GPS/MAT资料反演空气水汽含量产品和气象地面观测资料,并结合制药厂生产工艺,重点分析静电火灾事故原因。结果表明:高温低湿极端气象条件(空气中水汽含量达到0.5g/cm3、地表温度在40℃以上)是静电火灾发生的先决条件;生产工艺中防静电措施不合理,使静电产生和大量积聚,并产生火花放电,致使大量挥发的石油醚蒸汽燃烧而引发火灾,为减少类似静电火灾事故的发生,提出了相应防范建议以供参考。

关 键 词:极端气象条件  静电  火灾  防范
收稿时间:2010/10/27 0:00:00
修稿时间:2011/2/21 0:00:00

Analysis and Preventive Countermeasures for Electrostatic Fire Accidents Caused by Extreme Weather Condition
Li Jiaqi,Li Li,Huang Yamin,Qin Jian and Zeng Li.Analysis and Preventive Countermeasures for Electrostatic Fire Accidents Caused by Extreme Weather Condition[J].Meteorological Science and Technology,2012,40(2):310-314.
Authors:Li Jiaqi  Li Li  Huang Yamin  Qin Jian and Zeng Li
Institution:1 Nanjing University of Information Science & Technology,Nanjing 210044;2 Chongqing Beibei Meteorological Service,Chongqing 400700;3 Lightning Protection Center of Chongqing,Chongqing 401147)
Abstract:Taking a fire accident in at a pharmacy company in Chongqing on the September 2006 as an example,the causes of the electrostatic fire accident are analyzed by using the meteorological ground observation data and water vapor content inferred from GPS/MAT data,in combination with the production processes of the company.The results show that the extreme weather condition of high temperature and low moisture(air vapour content being 0.5 g/cm3,and surface temperature above 40 ℃) is the precondition for the electrostatic fire;another important cause is the incorrect measures for electrostatic prevention,which made a great deal of static electricity accumulated,produced spark discharge,and then led to the burning of a large amount of volatile petroleum aether vapour.In order to decrease the occurrences of the like electrostatic fire accidents,some precaution suggestions are given.
Keywords:extreme weather condition  static electricity  fire accident  prevention