首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An optimal procedure for identifying parameter structure and application to a confined aquifer
Authors:Ching-Pin Tung  Chung-Che Tan
Institution:(1) Department of Bioenvironmental Systems Engineering, National Taiwan University, Taipei, 106, Taiwan
Abstract:This study applies an optimal procedure to identify the spatial distribution of groundwater hydraulic conductivity for a confined aquifer in north Taiwan. The parameter structure is determined by the number of zones, zonation pattern, and an uniform hydraulic conductivity associated with each zone. The proposed optimal procedure uses the Voronoi diagram in describing zonation and applies simulated annealing algorithm to optimize its pattern and associated hydraulic conductivity. Three criteria are defined to stop the searching process, including the residual error, the parameter uncertainty, and the structure error. Observation hydraulic heads in years 2000 and 2001 and hydraulic conductivity value from pumping tests are used. The results show that the parameter structure with five zones conforms to the three criteria and, thus, is recommended for future groundwater simulation for the study site. Different heuristic algorithms may also play the role of simulated annealing to optimize the parameter structure. However, which optimization algorithm is more efficient is not discussed and requires further study.
Keywords:Groundwater  Inverse problem  Simulated annealing  Voronoi diagram  Taiwan
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏