A Compilation of Silicon,Rare Earth Element and Twenty‐One other Trace Element Concentrations in the Natural River Water Reference Material SLRS‐5 (NRC‐CNRC) |
| |
Authors: | Delphine Yeghicheyan Cécile Bossy Martine Bouhnik Le Coz Chantal Douchet Guy Granier Alexie Heimburger Francois Lacan Aurélie Lanzanova Tristan C. C. Rousseau Jean‐Luc Seidel Mickaël Tharaud Frédéric Candaudap Jérôme Chmeleff Christophe Cloquet Sophie Delpoux Marie Labatut Rémi Losno Catherine Pradoux Yann Sivry Jeroen E. Sonke |
| |
Affiliation: | 1. Service d'Analyse des Roches et des Minéraux (SARM), CNRS‐CRPG, , 54501 Vandoeuvre‐lès‐Nancy, France;2. Université de Bordeaux, EPOC UMR 5805, , 33405 Bordeaux, France;3. Géosciences Rennes, UMR 6118 CNRS – Université Rennes 1, Campus de Beaulieu, Rennes Cedex, , 35042 Rennes, France;4. Laboratoire Géosciences Montpellier, Laboratoire ICP‐MS, Batiment 22 5. cc060, Université Montpellier 2, , 34095 Montpellier Cédex 5, France;6. CEA/MARCOULE, DEN/DRCP/CETAMA, , 30207 Bagnols‐sur‐Cèze, France;7. Laboratoire Inter‐universitaire des Systèmes Atmosphériques, UMR 7583, CNRS‐Université Paris 8. Est‐Créteil‐Université 9. Paris Diderot, , F‐94010 Créteil, France;10. LEGOS (CNES/CNRS/IRD/University of Toulouse), Observatoire Midi‐Pyrénées, , 31400 Toulouse, France;11. Géosciences Environnement Toulouse, UMR 5563, Service ICP‐MS Observatoire Midi‐Pyrénées, CNRS, Université Paul Sabatier, IRD, , 31400 Toulouse, France;12. Géosciences Environnement Toulouse, Observatoire Midi‐Pyrénées, CNRS, Université Paul Sabatier, IRD, , 31400 Toulouse, France;13. Laboratoire HydroSciences Montpellier, UMR 5569, Université Montpellier 2, Case MSE, , 34095 Montpellier Cédex 5, France;14. Laboratoire de Géochimie des Eaux, Université Paris Diderot, Sorbonne Paris Cité, Institut de Physique du Globe de Paris, UMR 7154 CNRS, , F‐75205 Paris, France |
| |
Abstract: | The natural river water certified reference material SLRS‐5 (NRC‐CNRC) was routinely analysed in this study for major and trace elements by ten French laboratories. Most of the measurements were made using ICP‐MS. Because no certified values are assigned by NRC‐CNRC for silicon and 35 trace element concentrations (rare earth elements, Ag, B, Bi, Cs, Ga, Ge, Li, Nb, P, Rb, Rh, Re, S, Sc, Sn, Th, Ti, Tl, W, Y and Zr), or for isotopic ratios, we provide a compilation of the concentrations and related uncertainties obtained by the participating laboratories. Strontium isotopic ratios are also given. |
| |
Keywords: | river water reference material ICP‐MS rare earth elements trace elements maté riau de ré fé rence d'eau de riviè re ICP‐MS terres rares é lé ments en trace |
|
|