深层垂直井同轴换热能力数值模拟分析
引用本文:赵春虎,尚宏波,靳德武,王皓,徐拴海,王晓东,张卫东.深层垂直井同轴换热能力数值模拟分析[J].煤田地质与勘探,2020,48(5):174-181.
作者姓名:赵春虎  尚宏波  靳德武  王皓  徐拴海  王晓东  张卫东
作者单位:中煤科工集团西安研究院有限公司,陕西 西安 710077;陕西省煤矿水害防治技术重点实验室,陕西 西安 710077;中煤科工集团西安研究院有限公司,陕西 西安 710077
基金项目:天地科技股份有限公司科技创新基金;科技创新基金
摘    要:针对中深部(1 500~4 000 m)地热资源深井同轴“保水取热”科学评价问题,以COMSOL Multiphysics多物理场耦合数值计算软件为模拟平台,构建垂直单井岩-水耦合传热模型,以西安地区地层与地温特征为模拟背景,计算分析2种地温梯度(0.027、0.030℃/m)与4种注水口流速(0.25、0.50、0.75、1.00 m/s)工况下深层(3 500 m)地热单井套管换热能力。同时,建立5种井间距下的群井数值模型,分析不同井间距下群井中心井的出口温度变化规律。模拟结果显示:地温梯度越大,进出口温差越大,单位时间换热量与单位延米换热量越大;入口注水流速越大,进出口温差越小,但单位时间换热量与单位延米换热量越大,即地温梯度、流速越大,深层垂直钻孔套管换热的效率越高;西安地区3 500 m井深工况下,相邻地热井的间距为30 m时能够保证其地层温度不会相互干扰。研究结论可为深层地热开发利用提供科学参考。移动阅读 

关 键 词:深层地热能    单井    群井    延米取热量    COMSOL  Multiphysics
收稿时间:2020-02-25

Numerical simulation of coaxial heat transfer capacity of deep vertical wells
Abstract:Aiming at the scientific evaluation of coaxial casing heat transfer of geothermal resources with medium burial depth(1 500-4 000 m), a rock-water coupled heat transfer model of a vertical single well was built based on the simulation platform of COMSOL Multiphysics software. Taking the stratigraphic and geothermal characteristics of Xi'an area as the simulation background, the heat transfer capacity of single well(3 500 m)casing under two different geothermal gradients(0.027℃/m and 0.030℃/m) and four flow velocities(0.25, 0.50, 0.75, 1.00 m/s) was calculated and analyzed. Meanwhile, the numerical models of group wells with five kinds of well spacing were established, and the variation law of outlet temperature of the central group wells with different well spacing was analyzed. The simulation results show that the greater the geothermal gradient, the bigger the temperature difference between the inlet and the outlet, and the larger the heat transfer per unit time and the heat transfer per unit length of borehole. The larger the inlet injection velocity, the smaller the temperature difference between the inlet and the outlet, and the larger the heat transfer per unit time and per unit length of the borehole, which indicating that the higher the geothermal gradient and the flow velocity, the higher the heat transfer efficiency is. Under the deep working condition of 3 500 m in Xi'an area, when the distance between adjacent geothermal wells is 30 m, it would ensure that the formation temperature will not interfere with each other. The conclusion in this paper would provide scientific reference for the development and utilization of the deep geothermal resources. 
Keywords:
本文献已被 万方数据 等数据库收录!
点击此处可从《煤田地质与勘探》浏览原始摘要信息
点击此处可从《煤田地质与勘探》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号