首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A method for aligning the plastic scintillator detector on DAMPE
Authors:Peng-Xiong Ma  Yong-Jie Zhang  Ya-Peng Zhang  Yao Li  Jing-Jing Zang  Xiang Li  Tie-Kuang Dong  Yi-Zhong Fan  Shi-Jun Lei  Jian Wu  Yu-Hong Yu  Qiang Yuan  Chuan Yue  Zhi-Yu Sun
Abstract:The Plastic Scintillator Detector(PSD) onboard the DArk Matter Particle Explorer(DAMPE)is designed to measure cosmic ray charge(Z) and to act as a veto detector for gamma ray identification.To fully exploit the charge identification potential of PSD and to enhance its capability to identify gamma ray events, we develop an alignment method for the PSD. The path length of a given track in the volume of a PSD bar is derived taking into account the shift and rotation alignment corrections. By examining energy spectra of corner-passing events and fully contained events, position shifts and rotations of all PSD bars are obtained, and are found to be on average about 1 mm and 0.0015 radian respectively. To validate the alignment method, we introduce artificial shifts and rotations of PSD bars into the detector simulation.These shift and rotation parameters can be recovered successfully by the alignment procedure. As a result of the PSD alignment procedure, the charge resolution of the PSD is improved from 4% to 8%, depending on the nuclei.
Keywords:instrumentation:detectors  methods:data analysis
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号