Use of a resistivity cone for detecting contaminated soil layers
Authors:M Fukue  T Minato  M Matsumoto  H Horibe and N Taya
Institution:

a Marine Science & Technology, Tokai University, 3-20-1 Orido, Shimizu, 424-8610 Japan

b Koa Kaihatsu, Co., 5-3-13 Koutobashi, Sumida-ku, Tokyo, 130-0022, Japan

Abstract:A cone-penetration technique was developed to detect contaminated soil layers with electrolytes and NAPLs. In this study, laboratory and field experiments were performed to apply the technique. In the laboratory, the change in resistivity was quantitatively examined by adding salt or oil to soil samples. The results showed that the resistivity measurement was varied with an order of ppm for the electrolyte concentration in soil. It was found that the resistivity of sand increased with increasing oil concentration. The effect of oil content was stronger for lower water content of sand.

The results obtained from field experiments showed that the resistivity cone can be used for detecting the contaminated layer in soils whose background values are known. Particularly, the instrument can be used effectively for examining the effects of remediation, by measuring the resistivity of the ground before and after remediation, unless the soil fabric changes significantly during remediation procedures.

Keywords:In situ measurement  Cone penetration  Resistivity  Contaminated soils  Electrolytes  Light oil