Abstract: | The calibration of phototheodolites such as the Wild P32/T2 combination sometimes involves determining not only the camera interior orientation parameters but also the camera-to-theodolite parameters. The latter become particularly important when the theodolite set orientation parameters are to be used as observations, especially as known quantities for data reduction in subsequent photogrammetric applications. This paper presents experiments to determine these parameters for a Wild P32 camera using a new camera-on-theodolite method, with details of results achieved. |