On the design and seismic response of RC frame buildings designed with Eurocode 8 |
| |
Authors: | Jorge A Rivera Lorenza Petrini |
| |
Institution: | 1. ROSE School, European School for Advanced Studies in Seismic Risk, IUSS, Via Ferrata 1, 27100, Pavia, Italy 2. Politecnico di Milano, Department of Structural Engineering, Piazza Leonardo da Vinci, 20133, Milano, Italy
|
| |
Abstract: | Performance-Based Seismic Design is now widely recognized as the pre-eminent seismic design and assessment methodology for
building structures. In recognition of this, seismic codes may require that buildings achieve multiple performance objectives
such as withstanding moderate, yet frequently occurring earthquakes with minimal structural and non-structural damage, while
withstanding severe, but rare earthquakes without collapse and loss of life. These objectives are presumed to be satisfied
by some codes if the force-based design procedures are followed. This paper investigates the efficacy of the Eurocode 8 force-based
design provisions with respect to RC frame building design and expected seismic performance. Four, eight, and 16-storey moment
frame buildings were designed and analyzed using the code modal response spectrum analysis provisions. Non-linear time-history
analyses were subsequently performed to determine the simulated seismic response of the structures and to validate the Eurocode
8 force-based designs. The results indicate the design of flexural members in medium-to-long period structures is not significantly
influenced by the choice of effective member stiffness; however, calculated interstorey drift demands are significantly affected.
This finding was primarily attributed to the code’s enforcement of a minimum spectral ordinate on the design spectrum. Furthermore,
design storey forces and interstorey drift demand estimates (and therefore damage), obtained by application of the code force-based
design procedure varied substantially from those found through non-linear time-history analysis. Overall, the results suggest
that though the Eurocode 8 may yield life-safe designs, the seismic performance of frame buildings of the same type and ductility
class can be highly non-uniform. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|