首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Oxygen isotope fractionation between apatite-bound carbonate and water determined from controlled experiments with synthetic apatites precipitated at 10-37 °C
Authors:Christophe Lécuyer  Vincent Balter  François Fourel  Romain Amiot  Olga Otero  Gérard Panczer  Rossana Martini
Institution:a Laboratoire Paléoenvironnements & Paléobiosphère, CNRS UMR 5125, Université Lyon 1, Lyon 69622, France
b Laboratoire de Sciences de la Terre, CNRS UMR 5570, Université Lyon 1 et Ecole Normale Supérieure de Lyon, Lyon 69007, France
c iPHEP (Institut international de Paléoprimatologie, Paléontologie humaine: Evolution et Paléoenvironnements), UMR CNRS 6046, Université Poitiers, SFA, 40 avenue du recteur Pineau, F-86022 Poitiers Cedex, France
d Laboratoire de Physico-Chimie des Matériaux Luminescents, CNRS UMR 5620, Université Lyon 1, Lyon 69300, France
e Laboratoire d’Ecologie des Hydrosystèmes Fluviaux, UMR CNRS 5023, Université Lyon 1, Lyon, Bât. Forel, 69622 Villeurbanne Cedex, France
f Département de Géologie et Paléontologie, 13 rue des Maraîchers, CH-1205 Genève, Switzerland
Abstract:The oxygen isotope fractionation between the structural carbonate of inorganically precipitated hydroxyapatite (HAP) and water was determined in the range 10-37 °C. Values of 1000 ln α(View the MathML source) are linearly correlated with inverse temperature (K) according to the following equation: 1000 ln α(View the MathML source) = 25.19 (±0.53)·T−1 − 56.47 (±1.81) (R2 = 0.998). This fractionation equation has a slightly steeper slope than those already established between calcite and water ( O’Neil et al., 1969] and Kim and O’Neil, 1997]) even though measured fractionations are of comparable amplitude in the temperature range of these experimental studies. It is consequently observed that the oxygen isotope fractionation between apatite carbonate and phosphate increases from about 7.5‰ up to 9.1‰ with decreasing temperature from 37 °C to 10 °C. A compilation of δ18O values of both phosphate and carbonate from modern mammal teeth and bones confirms that both variables are linearly correlated, despite a significant scattering up to 3.5‰, with a slope close to 1 and an intercept corresponding to a 1000 ln α(View the MathML source) value of 8.1‰. This apparent fractionation factor is slightly higher or close to the fractionation factor expected to be in the range 7-8‰ at the body temperature of mammals.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号