Triple-Hot-Film Anemometer Performance in Cases-99 and A Comparison With Sonic Anemometer Measurements |
| |
Authors: | Brian T. Skelly David R. Miller Thomas H. Meyer |
| |
Affiliation: | (1) Department of Natural Resources Management and Engineering, University of Connecticut, 1376 Storrs Rd., U-4087, Storrs, CT, 06269-4087, U.S.A |
| |
Abstract: | Two levels of triple-hot-film and sonic anemometers were deployed on a 5.5-m towerduring the Cooperative Atmospheric Surface Exchange Study (CASES-99) in October1999. Each triple-hot-film probe was collocated 50 mm from the sonic sensing path ona common boom. Various problems with using triple-hot-films in the atmosphere toresolve wind components are addressed including the derivation of a yaw angle correction using the collocated sensors. It was found that output voltage drift due to changes in environmental temperature could be monitored and corrected using an automated system. Non-unique solutions to heat transfer equations can be resolved using a collocated sonic anemometer. Multi-resolution decomposition of the hot-film data was used to estimate appropriate day and night averaging periods for turbulent flux measurements in and near the roughness sub-layer. Finally, triple-hot-film measurements of mean wind magnitude (M), turbulent kinetic energy (TKE), sensible heat flux (H), and local friction velocity (u*) are compared to those of the collocated CSAT3 sonic anemometers. Overall, the mean wind magnitudes measured by the triple-hot-film and the collocated sonic sensorswere close, consistent and independent of stability or proximity to the ground. The turbulent statistics, TKE, u*, and H, measured by the two sensor systems were reasonably close together at z = 5 m. However, the ratio of sonic measurement/hot-film measurement decreased toward the ground surface, especially during stable conditions. |
| |
Keywords: | CASES-99 Friction velocity Sensible heat flux Sonic anemometer Triple-hot-film anemometer Turbulent kinetic energy |
本文献已被 SpringerLink 等数据库收录! |
|