首页 | 本学科首页   官方微博 | 高级检索  
     检索      

320排动态容积CT颅内动脉瘤图像重建算法进展和评估
引用本文:曹华,曹家义.320排动态容积CT颅内动脉瘤图像重建算法进展和评估[J].CT理论与应用研究,2014(2):329-335.
作者姓名:曹华  曹家义
作者单位:[1]华中科技大学软件学院,武汉430074 [2]广州军区武汉总医院神经外科,武汉430071
基金项目:基金项目:华中科技大学自主创新基金(18921003).
摘    要:320排动态容积CT脑血管数字减影(DSA)可为颅内动脉瘤病人提供4DDSA成像信息,这一技术的关键是宽体检测器和ConeXact锥束重建算法。本文对目前常见锥束扫描重建算法进行了分析和比较,特别是近几年发展起来的Feldkamp类,Grangeant类,Katsevich类和ConeXact锥束重建算法。应用方面对30例颅内动脉瘤患者进行了宽探测器平台下动态容积扫描,一次成像获得满意图像,无阶梯伪影,并与计算机断层血管造影(CTA)、常规DSA对比,320排CTDSA检查可作为颅内动脉瘤筛选和术后复查一种方法,与CTA相比320排CT动态容积成像和功能成像有明显的优势。

关 键 词:动态容积  螺旋锥束CT  颅内动脉瘤  图像评估  宽体探测器

Developments and Evaluated for Intracranial Aneurysm Imaging Reconstruction Algorithms by 320 Slice Dynamic Volume CT
Institution:CAO Hua, CAO Jla-yi 1.School of Software Engineering, Huazhong University of Science & Technology, Wuhan 430074, China 2.Department of Neurosurgery, Wuhan General Hospital of Guangzhou Military, Wuhan 430071, China
Abstract:320 slice dynamic volume CT provides intracranial aneurysm patience with 4D DSA imaging. The key of the technology is wide detection platform and ConeXact cone-beam reconstruction algorithm. In this thesis, some familiar cone-beam scan reconstruction algorithms are analyzed and compared, especially those algorithms which are currently developed such as Feldkamp-lype, Grangeant, Katsevich and ConeXact cone-beam reconstruction algorithm. In application aspect, 30 aneurysm patients have been through the dynamic volume scan with wide detection platform by TOSHIBA 320 slice CT. Good single-pass imaging results for 30 patients were obtained and all images had no phase artifacts. The quality of the scanning images was evaluated and compared between 320 slice CT and convention cerebral vascular DSA angiography had been done. 320 slice CT which is of a great value to diagnosing and treating intracranial aneurysm which may be used to screen out patient with susceptible intracranial aneurysm and the re-examination after the surgery the following up in the patient with aneurysm. 320 slice CT has great advantages in dynamic volume imaging and function when compared with CTA.
Keywords:dynamic volume  helical cone-beam CT  intracranial aneurysm  image evaluation  wide detectionplatform
本文献已被 维普 等数据库收录!