首页 | 本学科首页   官方微博 | 高级检索  
     检索      

敦煌场地CBERS-02 CCD传感器在轨绝对辐射定标研究
引用本文:傅俏燕,闵祥军,李杏朝,沙崇漠,李小英,马国强,潘志强,郭毅,李启明,刘国栋.敦煌场地CBERS-02 CCD传感器在轨绝对辐射定标研究[J].遥感学报,2006,10(4):433-439.
作者姓名:傅俏燕  闵祥军  李杏朝  沙崇漠  李小英  马国强  潘志强  郭毅  李启明  刘国栋
作者单位:1. 中国资源卫星应用中心,北京,100073
2. 中国科学院,遥感应用研究所,北京,100101
摘    要:对资源一号卫星02星(CBERS-02),为深入其定量化分析,定期在敦煌绝对辐射校正场地进行了地面同步测量,开展了更新在轨绝对辐射定标研究。另外,运用地表反射率和大气光学特性参量数据,计算出CBERS-02CCD传感器4个波段的绝对辐射标定系数。同时,利用2004年8月25目的Landsat-5 TM图像数据对CBERS-02 CCD传感器的辐射特性进行交叉定标,验证分析了CBERS-02 CCD传感器场地绝对辐射定标的基本特性及其可靠性。另外,为CBERS后续星的传感器改进,提供了分析参量。

关 键 词:资源一号卫星02星  绝对辐射定标  交叉定标  敦煌场地
文章编号:1007-4619(2006)04-0433-07
修稿时间:2005年3月1日

In-flight Absolute Calibration of the CBERS-02 CCD Sensor at the Dunhuang Test Site
FU Qiao-yan,MIN Xiang-jun,LI Xing-chao,SHA Chong-mo,LI Xiao-ying,MA Guo-qiang,PAN Zhi-qiang,GUO Yi,LI Qi-ming and LIU Guo-dong.In-flight Absolute Calibration of the CBERS-02 CCD Sensor at the Dunhuang Test Site[J].Journal of Remote Sensing,2006,10(4):433-439.
Authors:FU Qiao-yan  MIN Xiang-jun  LI Xing-chao  SHA Chong-mo  LI Xiao-ying  MA Guo-qiang  PAN Zhi-qiang  GUO Yi  LI Qi-ming and LIU Guo-dong
Institution:FU Qiao-yan~,MIN Xiang-jun~,LI Xing-chao~,SHA Chong-mo~,LI Xiao-ying~,MA Guo-qiang~,PAN Zhi-qiang~,GUO Yi~,LI Qi-ming~,LIU Guo-dong~
Abstract:Since(CBERS- 02) was successfully launched on October 21,2003,the data of(CBERS- 02) has been widely applied to the fields for agriculture,forestry,geology,water conservancy ect.It is very necessary to update the coefficient of absolute radiometric calibration in order to deeply carry on the research of quantitative approaches.Therefore,China Centre for Resources Satellite Data & Application team has conducted a field measurement campaign for the characteristic of ground reflectance and of the atmosphere.The results show that the test site of Dunhuang is very homogeneous and the variation of ground material reflectance is about 5%.The results of atmospheric measurements have shown that the aerosol optical depth(<0.14) is very low.The coefficients of CBERS- 02 CCD sensor for four bands have been obtained through the "6S" atmospherical transfer code.Simultaneously,the cross-calibration of Landsat-5 TM and CBERS- 02 CCD based on the image of August 25,2004 was made.It shows that the consistency between the results from Dunhuang site calibration and cross-calibration varies less than 6% except band 3.The field measurement verified the radiometric performance and reliability for the absolute calibration of CBERS- 02 CCD sensor.
Keywords:China-Brazil Earth Resources Satellite(CBERS- 02)  absolute radiometric calibration  cross-calibration  the Dunhuang test site
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《遥感学报》浏览原始摘要信息
点击此处可从《遥感学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号