Recommended Values of 239Pu, 240Pu and 239+240Pu Concentrations in Reference Material IAEA-315 (Marine Sediment) Estimated by Thermal Ionisation Mass Spectrometry, Inductively Coupled Plasma-Mass Spectrometry and Alpha Spectrometry
Authors:Taeko Shinonaga  Helmuth Aigner  Dilani Klose  Peter Spinder  Heinz Fröschl  David Donohue
Institution:Safeguards Analytical Laboratory, IAEA Agency's Laboratories Seibersdorf, Wagramer Strasse 5, PO Box 100, A-1400 Vienna, Austria;Austrian Research Centers GmbH-ARC, Chemical Analytics, A-2444 Seibersdorf, Austria
Abstract:The recommended concentrations of 239Pu, 240Pu and 239+240Pu in reference material IAEA‐315 (marine sediment) were estimated by three analytical methods: isotope dilution thermal ionisation mass spectrometry (TIMS), isotope dilution inductively coupled plasma‐mass spectrometry (ICP‐MS) and alpha spectrometry. The determination of 239Pu and 240Pu (239+240Pu by alpha spectrometry) was carried out with samples from randomly selected bottles using each method. Plutonium‐238 was also measured by alpha spectrometry. A plutonium‐242 reference material was used as a spike for the quantitative analysis. The influence of 242Pu in the samples was therefore calculated; however, this contribution was less than the range of uncertainty and did not influence the final results. The obtained data were statistically analysed using variance component analysis and paired comparison. The combined standard uncertainties from “method/measurement”, “bottle” and “sub‐sample” were in the order of 3 to 6%. The main contributions to the uncertainty were from the material heterogeneity and from systematic differences between methods. Based on this study with twenty‐seven analyses using 10–14 g sample mass, concentrations of (38 ± 3) Bq kg?1, (28 ± 3) Bq kg?1 and (66 ± 4) Bq kg?1 are proposed as recommended values for 239Pu, 240Pu and 239+240Pu, respectively, and (9.5 ± 0.4) Bq kg?1 for 238Pu as an information value in reference material IAEA‐315. In mass concentration units, these amount to (16.4 ± 1.2) ng kg?1, (3.3 ± 0.4) ng kg?1 and (0.015 ± 0.003) ng kg?1 for 239Pu, 240Pu and 238Pu, respectively. The certified reference materials NIST 4350B and NIST 4354 were also analysed by TIMS for quality assurance of the method used in this study.
Keywords:239Pu              240Pu              239+240Pu  recommended value  reference material  IAEA-315  NIST 4350B  NIST 4354  thermal ionisation mass spectrometry  inductively coupled plasma-mass spectrometry  alpha spectrometry
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号