首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Predominant period and equivalent viscous damping ratio identification for a full‐scale building shake table test
Authors:Michelle C Chen  Rodrigo Astroza  José I Restrepo  Joel P Conte  Tara Hutchinson  Yehuda Bock
Institution:1. Department of Structural Engineering, University of California, San Diego, CA, U.S.A.;2. Facultad de Ingeniería y Ciencias Aplicadas, Universidad de los Andes, Santiago, Chile;3. Scripps Institution of Oceanography, University of California, San Diego, CA, U.S.A.
Abstract:The predominant period and corresponding equivalent viscous damping ratio, also known in various loading codes as effective period and effective damping coefficient, are two important parameters employed in the seismic design of base‐isolated and conventional building structures. Accurate determination of these two parameters can reduce the uncertainty in the computation of lateral displacement demands and interstory drifts for a given seismic design spectrum. This paper estimates these two parameters from data sets recorded from a full‐scale five‐story reinforced concrete building subjected to seismic base excitations of various intensities in base‐isolated and fixed‐base configurations on the outdoor shake table at the University of California, San Diego. The scope of this paper includes all test motions in which the yielding of the reinforcement has not occurred and the response can still be considered ‘elastic’. The data sets are used with three system identification methods to determine the predominant period of response for each of the test configurations. One of the methods also determines the equivalent viscous damping ratio corresponding to the predominant period. It was found that the predominant period of the fixed‐base building lengthened from 0.52 to 1.30 s. This corresponded to a significant reduction in effective system stiffness to about 16% of the original stiffness. The paper then establishes a correlation between predominant period and peak ground velocity. Finally, the predominant periods and equivalent viscous damping ratios recommended by the ASCE 7‐10 loading standard are compared with those determined from the test building. Copyright © 2017 John Wiley & Sons, Ltd.
Keywords:base isolation  effective system stiffness  equivalent viscous damping ratio  predominant period  shake table testing
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号