首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A new formulation of garnet–clinopyroxene geothermometer based on accumulation and statistical analysis of a large experimental data set
Authors:D NAKAMURA
Institution:Department of Earth Sciences, Faculty of Science, Okayama University, Tsushima-naka 3-1-1, Okayama 700 8530, Japan ()
Abstract:Published experimental data including garnet and clinopyroxene as run products were used to develop a new formulation of the garnet–clinopyroxene geothermometer based on 333 garnet–clinopyroxene pairs. Only experiments with graphite capsules were selected because of difficulty in estimating the Fe3+ content of clinopyroxene. For the calibration, a published subregular‐solution model was adopted to express the non‐ideality of garnet. The magnitude of the Fe–Mg excess interaction parameter for clinopyroxene (WFeMgCpx), and differences in enthalpy and entropy of the Fe–Mg exchange reaction were regressed from the accumulated experimental data set. As a result, a markedly negative value was obtained for the Fe–Mg excess interaction parameter of clinopyroxene (WFeMgCpx = ? 3843 J mol?1). The pressure correction is simply treated as linear, and the difference in volume of the Fe–Mg exchange reaction was calculated from a published thermodynamic data set and fixed to be ?120.72 (J kbar?1 mol?1). The regressed and obtained thermometer formulation is as follows: image where T = temperature, P = pressure (kbar), A = 0.5 Xgrs (Xprp ? Xalm ? Xsps), B = 0.5 Xgrs (Xprp ? Xalm + Xsps), C = 0.5 (Xgrs + Xsps) (Xprp ? Xalm), Xprp = Mg/(Fe2+ + Mn + Mg + Ca)Grt, Xalm = Fe/(Fe2+ + Mn + Mg + Ca)Grt, Xsps = Mn/(Fe2+ + Mn + Mg + Ca)Grt, Xgrs = Ca/(Fe2+ + Mn + Mg + Ca)Grt, XMgCpx = Mg/(Al + Fetotal + Mg)Cpx, XFeCpx = Fe2+/(Al + Fetotal + Mg)Cpx, KD = (Fe2+/Mg)Grt/(Fe2+/Mg)Cpx, Grt = garnet, Cpx = clinopyroxene. A test of this new formulation to the accumulated data gave results that are concordant with the experimental temperatures over the whole range of the experimental temperatures (800–1820 °C), with a standard deviation (1 sigma) of 74 °C. Previous formulations of the thermometer are inconsistent with the accumulated data set; they underestimate temperatures by about 100 °C at >1300 °C and overestimate by 100–200 °C at <1300 °C. In addition, they tend to overestimate temperatures for high‐Ca garnet (Xgrs ≈ 0.30–0.50). This new formulation has been tested against previous formulations of the thermometer by application to natural eclogites. This gave temperatures some 20–100 °C lower than previous formulations.
Keywords:clinopyroxene  excess interaction  garnet  regular solution  thermometer
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号