首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   2篇
  免费   0篇
地球物理   1篇
地质学   1篇
  2021年   2篇
排序方式: 共有2条查询结果,搜索用时 78 毫秒
1
1.

This paper describes the main features related to lateral displacements with depth after successive lateral loading–unloading cycles applied to the top of reinforced-concrete flexible bored piles embedded in naturally bonded residual soil. The bored piles under study have a cylindrical shape, with 0.40-m in diameter and 8.0-m in length. Both bored piles types (P1 and P2) include an embedded steel pipe section in their center as longitudinal steel reinforcements: pile type P1 has another 16 steel rods as steel reinforcement to concrete while pile type P2 has no further steel reinforcement. Pile type P1 has three times as much stiffness (EI) and four and a half times the plastic moment (My) than pile type P2. A similar load–displacement performance was observed at initial loads as for small displacements of both piles. At this initial loading stage, the response of the reinforced concrete piles is a function of the soil characteristics and of a linear elastic pile deformation. During this stage, piles can even be understood as probes for evaluating soil reactions. For larger horizontal displacements, after the concrete section starts undergoing large deformations, approaching the ultimate bending moment, pile behavior and consequently the load–displacement relation starts to diverge for both piles. For pile P1 the values of relevant lateral displacements are extended to about 2.5-m in depth, while for pile P2 lateral displacements are mostly constrained to about 2.0-m in depth. Measurements of horizontal displacements of pile P1 against depth recorded with a slope indicator show that, after unloading, lateral loads at distinct stages (small and near failure loads), exhibits a much higher elastic phase of the system response. An analytical fitting model of soil reaction is proposed based on the measured displacements from slope indicator. The integration of a continuous model proposed for the soil reaction agrees fairly well with the measured displacements up to moments close to plastic limit. Results of load–displacement show that the stiffer pile (P1) was able to mobilize twice as much lateral load compared to pile P2 for a service limit displacement of about 20 mm. The paper shows results that enable the isolation of the structural variable through real scale pile load tests, thus granting understanding of its importance and enabling its quantitative visualization in examples of piles embedded in residual soil sites.

  相似文献   
2.
The anomalous entrance of water into groundwater systems can affect storage throughout long periods and normally relies on infrequent and irregular pulses of groundwater recharge defined by the term episodic recharge. Recently there was a groundwater recharge of large magnitude with unknown circumstances in the Caiuá aquifer. This unique event was explored in detail here and allowed to better understand the occurrence of such events in humid subtropical climates in South America. For this study, groundwater monitoring daily data from the Integrated Groundwater Monitoring Network was used combined with a specific yield obtained from geophysical wireline logging to obtain groundwater recharge rates. To improve the investigation, we also used a baseflow separation method to obtain the groundwater contribution into local rivers. The groundwater storage variations were also assessed by remote sensing with the GRACE data. Results showed the importance of high soil moisture storage on the occurrence of large episodic recharge events. We estimated that the groundwater recharger volumes derived from 1 year that included the unique episodic recharge observed (total of 866 mm for April 2015–March 2016) were comparable with the sum of 7 years of groundwater recharge (total of 867 mm). Atypical rainfall in winter periods were responsible for the increase in soil moisture that explained that unique event. GRACE-based GWS showed concordance detecting the occurrence of the unique episodic recharge. However, the variation in terms of volumes obtained by GRACE does not represent the behaviour observed in the aquifer by the WTF method. The results also indicated that changes in aquifer storage caused by episodic recharge events directly affect low flows in rivers over long periods. The main knowledge gap addressed here relates to exploring a unique episodic recharge event quite rare to observe with its long-term impacts on hydroclimatic variability over a humid subtropical portion of the Caiuá aquifer.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号