首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   26篇
  免费   0篇
大气科学   1篇
地球物理   6篇
地质学   15篇
海洋学   4篇
  2018年   1篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2010年   2篇
  2009年   2篇
  2008年   3篇
  2007年   2篇
  2006年   5篇
  2005年   3篇
  2004年   1篇
  2000年   2篇
  1998年   1篇
  1983年   1篇
排序方式: 共有26条查询结果,搜索用时 734 毫秒
1.
Development of fouling communities on vertical structures in the Baltic Sea   总被引:6,自引:2,他引:6  
The pillars of the bridge connecting the Island of Öland with the Swedish mainland were rebuilt between 1990 and 2000. The renovation produced pristine vertical concrete substrates, which became submerged in known years and seasons. The fouling communities on the pillars were examined in 2001 to determine whether the community structure could be explained in terms of either orderly successional development or of seasonal variation in the settlement of benthic organisms. As well, the communities on the pillars were compared to communities on the vertical surfaces of boulders in the area. The results indicated that an annual species composition is the final stage in the succession on the observed, vertical constructions. The few perennial species add to the variation between pillars as they increase in biomass (Polysiphonia fucoides) or become out-competed (Balanus improvisus). Also, observed seasonal differences in the biomass of these perennial species indicated that the time of year free space becomes available might be an important determinant of the future structure of the community. Comparison between the pillar and boulder communities showed that the artificial structures were not surrogates for the natural hard substrate: pillar communities differed in that they lacked most perennial algal species and had a high biomass of B. improvisus.  相似文献   
2.
Long held notions that climate has been stable over the Yucatan peninsula and that today's climate is an accurate reflection of past climates here are being challenged today by a number of researchers. Both empirical and circumstantial evidence are offered for a prolonged and severe period of dessication in the Maya lowlands and its effects on soils, vegetation, lake levels and ancient Maya cultural processes, ca. 50 B.C. to 500 A.D. After centuries of steady and precocious growth and development, Late Preclassic Maya civilization in the drier northern two thirds of the peninsula abruptly collapsed, probably due to repeated crop failures and decreasing availabilities of potable water due to severe drought conditions. This is nowhere more apparent than at the predominantly Preclassic ruins of El Mirador - the largest known ancient Maya city - which was almost totally abandoned by A.D. 250. Thereafter, the development of classicism was confined to a small and better watered area in extreme northeastern Guatemala, northern Belize and southern Quintana Roo, which was defended from invaders from the north by a line of fortified sites.  相似文献   
3.
Resistivity in horizontal boreholes can give useful detailed information about the geological conditions for construction in rock, i.e. in front of a tunnel bore machine. This paper is an attempt to identify a suitable methodology for an effective measuring routine for this type of geophysical measurements under actual construction site conditions.Prior to any measurements numerical modelling was done in order to evaluate the resolution of different electrode arrays. Four different arrays were tested; dipole–pole, cross-hole dipole–dipole, cross-hole pole–tripole and multiple gradient array. Additionally the resolution of a combination of cross-hole dipole–dipole and multiple gradient was assessed. The 2D sensitivity patterns for various arrangements of the cross-hole dipole–dipole and multiple gradient array were examined. The sensitivity towards inaccurate borehole geometry and the influence of water in the boreholes were also investigated. Based on the model study the cross-hole dipole–dipole array, multiple gradient array and a combination of these were found to give the best result and therefore were used for test measurements in horizontal boreholes. The boreholes were 28.5 m long and drilled 6.5 m apart. Prototypes of semi-rigid borehole cables made it possible to insert multi electrode cables in an efficient way, allowing fast measurement routines. These measurements were then studied to determine their accuracy and applicability. The results showed a high resistivity rock mass at the site. A transition from high resistivity to slightly lower resistivity coincides well with a change in lithology from gneiss-granite to gneiss. It is likely that the shotcrete on the tunnel wall is seen as a low resistivity zone.The measurements are a valuable tool, but further development of the cables and streamlining of measuring routines have to be performed before the resistivity tomography can be used routinely in pilot holes during construction in rocks.  相似文献   
4.
The measurement sequence used in DC resistivity data using multi-electrode arrays should be carefully designed so as to minimize the effects of electrode charge-up effects. These effects can be some orders of magnitude larger than the induced signal and remain at significant levels for tens of minutes. Even when using a plus-minus-plus type of measurement cycle, one should avoid making potential measurements with an electrode that has just been used to inject current, as the decay immediately after current turn-off is clearly non-linear.  相似文献   
5.
6.
7.
Internal erosion is a major reason for embankment dam failures. Resistivity measurements is an essentially non-destructive technique, which may have the possibility of detecting internal erosion processes and anomalous seepage at an early stage before the safety of the dam is at stake. This paper presents results from part of a dam safety investigation conducted at the Enemossen tailings dam in southern Sweden. Longitudinal resistivity sections, 2D measurements along the dam crest, provided an overview of the whole dam and served to detect anomalous zones. In selected areas, additional cross-sectional 2D surveys gave detailed information about the geo-electrical situations in the embankments. This information is valuable for similar investigations as information about resistivity in embankment construction material is scarce. Known problem areas were associated with low resistivities, even though the resistivity measurements alone did not provide enough information to confidently come to a decision about the status of the dams.
S. JohanssonEmail:
  相似文献   
8.
 Geophysical investigations using 2-D DC resistivity were carried out on old parts of two similar landfills, with waste of different ages. The data sets, which included high data density in both vertical and horizontal directions, were interpreted with 2-D smoothness constrained inversion. The landfills were excavated after the surveying. The objective was to test the capability of the resistivity method as a pre-characterization technique. The objectives were only partially fulfilled. First, the moisture content was the parameter that appeared to exert the dominant control over the resistivity distribution of the landfill. The most important potential information that can be recovered is, therefore, an indication of the waste piles hydraulics. Second, it was neither possible to estimate the amount of recoverable soils, nor to correlate the type of waste with the resistivity models. However, discrete anomalies were identified, and if specific materials are searched for, the resistivity models indicate possible places to search. Received: 23 July 1998 · Accepted: 20 October 1998  相似文献   
9.
Electrical geophysical surveys in the mode of vertical electrical soundings (VES) and continuous vertical electrical soundings (CVES) were conducted in the León-Chinandega plains, northwestern Nicaragua, in order to obtain detailed information about the geometry of the different hydrogeological layers in the aquifer and depth to the basement. A total of 51 VES were carried out within the plains. The results show a complex structure towards the north east of the area, and the southwestern part of the plains presents a smoother stratification. The geoelectrical measurements and borehole information indicate that the basement topography is characterized by hills and deep valleys with highly variable basement depths. Fifty CVES where done in a smaller area in the center of the plain. The resistivity data yielded considerable information revealing the existence of two main geo-electrical units. The combined interpretation of geological and geophysical data shows an environment typical of sedimentary volcanic coastal plains. The information collected during this investigation provides valuable data for estimating the fresh-water resources of the León-Chinandega aquifer system and for development of a groundwater management plan.  相似文献   
10.
This study focusses on the hydrogeology of Urema Graben, especially possible interactions between surface water and groundwater around Lake Urema, in Gorongosa National Park (GNP). Lake Urema is the only permanent water source for wildlife inside GNP, and there are concerns that it will disappear due to interferences in surface-water/groundwater interactions as a result of changes in the hydraulic environment. As the lake is the only permanent water source, this would be a disaster for the ecosystem of the park. The sub-surface geology in Urema Graben was investigated by 20 km of electrical resistivity tomography (ERT) and three magnetic resonance sounding (MRS) surveys. The average depth penetration was 60 and 100 m, respectively. The location of the ERT lines was decided based on general rift morphology and therefore orientated perpendicular to Urema Graben, from the transitional areas of the margins of the Barue platform in the west to the Cheringoma plateau escarpments in the east. ERT and MRS both indicate a second aquifer, where Urema Lake is a window of the first upper semi-confined aquifer, while the lower aquifer is confined by a clay layer 30–40 m thick. The location and depth of this aquifer suggest that it is probably linked to the Pungwe River which could be a main source of recharge during the dry season. If a dam or any other infra-structure is constructed in Pungwe River upstream of GNP, the groundwater level will decrease which could lead to drying out of Urema Lake.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号