Shaking table tests were conducted by means of a large-scale laminar box with 4 m in length, 2 m in width and 2 m in height in order to investigate behavior of a soil-pile-superstructure system in liquefiable ground. A model two-storey structure, supported by a pile group, was set in a saturated sand deposit, and subjected to a sinusoidal base motion with increasing amplitude. Discussions are focused on the transient behavior until soil liquefaction occurs. Main interests are characteristics of springs used in a sway-rocking model and a multi-freedom lumped mass (MFLM) model that are frequently used in soil–pile interaction analysis. The spring constant in the sway-rocking model is represented by restoring force characteristics at the pile head, and that in the MFLM system is represented by an interaction spring connecting the pile to the free field. The transient state prior to soil liquefaction is shown to be important in the design of a pile because dynamic earth pressure shows peak response in this state. The reduction of the stiffness due to excess porewater generation and strain dependent nonlinear behavior is evaluated. 相似文献
The bus route map is a diagram that aims to convey necessary information for map readers to find an appropriate way of moving from an origin to a destination. Design of bus route map is a complicated and time-consuming task that requires careful consideration of readability and aesthetics. This paper proposes a new computational method for designing bus route maps. The method helps us to reduce six types of undesirable elements in bus route maps, i.e., gap, shift, crossing, overlap, misalignment, and acute bend. The method consists of two phases: line layout phase determines the relative order of bus routes on each road segment and map layout phase calculates the actual position of bus routes drawn on a map. This paper applies the method to the design of bus route maps of Chiba City, Japan. The result supports the effectiveness of the method as well as reveals open topics for future research. 相似文献
We describe a least-squares inversion approach to estimating the subsurface resistivity structure from cross-hole or borehole-to-surface electromagnetic data. It is assumed that the resistivity distribution is symmetric about the axis of a borehole and that vertical magnetic dipoles are located on the borehole axis. The receivers are placed either in another borehole or on the earth's surface. The inversion scheme uses the finite-element and smoothness-constrained least-squares methods. The computational effort required to obtain partial derivatives is reduced considerably by using the reciprocity principle. Numerical simulations show that the reconstructions are generally in good agreement with the true structures when the assumption of an axisymmetric earth structure holds. An example involving the breakdown of this assumption, which can be obtained by interchanging the source and receiver boreholes, suggests that the inversion result may also be useful for locating a general 3D anomaly although artifacts are present. 相似文献
Two lysimeters with the same dimensions were provided, and filled with the same loam clay. On the soil surface of one lysimeter, grass was planted to compare the hydrologic response of the grassed lysimeter with that of the other bare soil lysimeter.
About half of the runoff from the bare soil lysimeter occurred as overland flow, the rest being groundwater flow. Overland flow scarcely occurred from the grassed lysimeter. Grass roots that developed deep into the soil layer play an important role in increasing the infiltration rate as well as in drying the soil uniformly throughout the soil layer by evapotranspiration, preparing for high infiltration and large rainwater storage for the subsequent rainfall event. Accordingly, the total loss by evapotranspiration from the grassed soil amounts to almost twice that from the bare soil.
For an evaporation- and evapotranspiration-prohibited experiment, the recession characteristics from a saturation state showed similar features for the bare and grassed soils, indicating the same microstructure of high moisture reservability for both soils.
The well-developed grass root system reformed the soil structure considerably to produce the seemingly contradicting characteristics of high moisture conductivity and high moisture reservability; i.e. a high infiltration rate and prolonged groundwater discharge.
Finally, the importance of the initial soil moisture in the rainfall-runoff process, rainfall loss and runoff ratio is stressed. 相似文献
Measurements of fog and rain water chemistry at the summit of Mt. Fuji, the highest peak in Japan, as well as at Tarobo, the ESE slope of Mt. Fuji in September 2002. The pH of fog and rain water sampled at Mt. Fuji varied over a range of 4.0–6.8. Acidic fogs (pH < 5.0) were observed at the summit when the air mass came from the industrial regions on the Asian continent. The ratio of [SO42−]/[NO3−] in the fog water was lower at Tarobo than at the summit. High concentrations of Na+ and Cl− were determined in the rain water sampled at the summit, possibly because of the long-range transport of sea-salt particles raised by a typhoon through the middle troposphere. The vertical transport of sea-salt particles would influence the cloud microphysical properties in the middle troposphere. Significant loss of Mg2+ was seen in the rain water at the summit. The concentrations of peroxides in the fog and rain water were relatively large (10–105 μM). The potential capacity for SO2 oxidation seems to be strong from summer to early autumn at Mt. Fuji. The fog water peroxide concentrations displayed diurnal variability. The peroxide concentrations in the nighttime were significantly higher than those in the daytime. 相似文献
Oxygen isotope exchange between anhydrite and water was studied from 100 to 550°C, using the partial equilibrium method. The exchange rate was extremely low in NaCl solution. In the lower-temperature range, acid solutions were used to produce sufficient reaction to determine the oxygen isotope fractionation factors. The fractionation factors obtained in the present study are definitely different from those given by Lloyd [8]. They are similar to those for the HSO4?-water system studied by Mizutani and Rafter [19], and are consistently 2‰ higher than those of the barite-water system by Kusakabe and Robinson [5]. The temperature dependence of the oxygen isotope fractionation factors was calculated by the least squares method in which the weight was taken to be inversely proportional to the experimental error. The fractionation is given by:103lnαanhydrite-water=3.21×(103/T)2?4.72Available δ18O values of natural anhydrite were used to test the validity of this expression. It is shown that this newly revised geothermometer can be successfully applied to natural hydrothermal anhydrite. 相似文献
Pagurus hermit crabs have a well‐developed right cheliped (major cheliped) and in some species the major cheliped of males is longer than that of females. This paper describes sex‐related differences in major cheliped length and regeneration pattern of the major cheliped in the hermit crab Pagurus filholi. We also examined the function of the major cheliped in male–male competition. Major cheliped length of males was longer than that of females in P. filholi. Males regenerated larger chelipeds than females at the first molt after experimentally induced autotomy. Body size growth in males of the regeneration group was less than that in intact males of the control group while there was no significant difference in body size growth of females between regeneration and control groups. Major cheliped length was included in the best model to explain the outcome of male–male competition and thus sexual selection appears to be a causative factor in the sex‐related difference of the major cheliped length. Sex‐related differences in the regeneration pattern may reflect differences in evolutionary pressures on males for large major chelipeds and females for large body size. 相似文献
Measurements of size-separated aerosol number concentrations at Midagahara (altitude, 1,930 m), on the western slope of Mt. Tateyama near the coast of the Japan Sea, were performed each autumn from 2006 to 2011. High number concentrations of particles larger than 2 μm were frequently seen in 2006 and 2009 when the influence of Asian dust might have been significant. The pH and the ratio of Ca2+ to total ions were high in the rainwater bulk sampled when high number concentrations of coarse particles were observed. The mean pH of rainwater during the autumn in 2006 was significantly higher than that in 2007 and 2008. Acidic species might have been neutralized by the Asian dust particles. Dust particles may highly affect the natural environment, such as forest ecosystems, at high elevations during seasons without snow cover. 相似文献