首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   56篇
  免费   22篇
  国内免费   9篇
测绘学   2篇
大气科学   2篇
地球物理   5篇
地质学   72篇
海洋学   4篇
综合类   2篇
  2021年   2篇
  2020年   13篇
  2019年   7篇
  2018年   5篇
  2017年   7篇
  2016年   9篇
  2015年   6篇
  2014年   6篇
  2013年   3篇
  2012年   7篇
  2011年   6篇
  2010年   1篇
  2009年   1篇
  2008年   2篇
  2007年   1篇
  2006年   5篇
  2003年   2篇
  2002年   1篇
  2001年   1篇
  1998年   2篇
排序方式: 共有87条查询结果,搜索用时 31 毫秒
61.
We report here an optimisation of the demountable direct injection high efficiency nebuliser (d‐DIHEN) for isotopic measurements with a Neptune (ThermoFisher Scientific, Bremen, Germany) multi‐collector inductively coupled plasma‐mass spectrometer (MC‐ICP‐MS) and describe a method for boron isotopic ratio determination. With direct injection nebulisation 100% of the analyte was introduced into the ICP‐MS plasma and wash times were drastically reduced for elements such as boron and thorium. Compared to the classical stable introduction system (SIS: double Scott/cyclonic spray chamber), sensitivity for boron was 2–5 times higher with d‐DIHEN and wash times up to ten times shorter. Repeatability of 11B/10B sample‐calibrator bracketing measurements reached 0.25‰ (2s) for seawater and coral samples. Method accuracy and reproducibility were tested on mixed reference solutions having δ11B values in the ranges ?90 to +40‰ and ?2 to +2.5‰, demonstrating our ability to distinguish δ11B values with differences of only 0.25‰. The international seawater reference material NRCC NASS‐5 (National Research Council, Ottawa, Canada), analysed in different sessions over a 10‐month period, yielded an average δ11B value of +39.89 ± 0.25‰, in the upper range of previously published seawater values. A comparison between δ11B determined by d‐DIHEN MC‐ICP‐MS and positive‐TIMS (P‐TIMS) for four modern corals showed an excellent agreement (with bias of less than 0.4‰).  相似文献   
62.
We present the first measurements of vanadium (V) stable isotopes for six reference materials – USGS PCC‐1, BHVO‐2, BCR‐2, BIR‐1a, GSP‐2 and AGV‐2 – plus the widely available carbonaceous chondrite Allende. We present standard addition and matrix spiking tests to assess the robustness and reproducibility of our data. Standard addition utilised an enriched 50V solution designated VISSOX (Vanadium Isotope Standard Solution OXford). We further assessed the veracity of the method by spiking collected sample matrices with the same amount of a V standard solution, whose isotopic composition was defined as 0‰. Standard addition and matrix spiking tests recorded no appreciable artificial isotope fractionation. We estimate that the best currently attainable long‐term reproducibility of stable 51V/50V isotope measurements in complex matrices is 0.15‰, which is in the same order as the reproducibility achievable with standard solutions. Finally, a large range of ~ 1.2‰ in stable V isotopic composition was documented, with ~ 0.5‰ of that variation in high temperature igneous materials alone. The range and resolving power of V stable isotopes, with respect to igneous material, compared favourably with the magnitude of fractionation reported for other non‐traditional stable isotope systems, which bodes well for the utility of this new system.  相似文献   
63.
Geochemical studies of geological samples require the precise determination of their major and trace element contents and, when measured, of their isotopic compositions. It is now commonly accepted that the accuracy and precision of geochemical analyses are best estimated by the concomitant analysis of international reference materials run as unknown samples. Although the composition of a wide selection of basalts is relatively well constrained, this is far from being the case for sedimentary materials. We present here a comprehensive set of major and trace element data as well as Nd, Hf, Sr and Pb isotopic compositions for thirteen commonly used international reference materials – eight magmatic rocks (BHVO‐2, BR, BE‐N, BR 24, AGV‐1, BIR‐1, UB‐N, RGM‐1) and five sediments (JLk‐1, JSd‐1, JSd‐2, JSd‐3, LKSD‐1). We determined the concentrations of over forty elements in the magmatic rocks together with Sr, Nd, Hf and Pb isotopic compositions. Our trace element results were both accurate (difference ≤ 3%) and precise (reproducibility at 1s ≤ 3%) and the isotopic results were very similar to other published values. In contrast, we observed a significant chemical and isotopic variability in the sedimentary materials, which we attribute to mineral heterogeneities in the powders. Despite the limitation imposed by this heterogeneity, our work presents a complete set of data determined with a precision not yet achieved in the literature for sedimentary material. We also provide the first Nd, Hf and Pb isotopic measurements for the five sediments, which are commonly used by the geochemical community. Our study of both basalt and sediment reference materials represents a comprehensive and self‐consistent set of geochemical data and can therefore be considered as a reference database for the community.  相似文献   
64.
Molybdenum isotopes are increasingly widely applied in Earth Sciences. They are primarily used to investigate the oxygenation of Earth's ocean and atmosphere. However, more and more fields of application are being developed, such as magmatic and hydrothermal processes, planetary sciences or the tracking of environmental pollution. Here, we present a proposal for a unifying presentation of Mo isotope ratios in the studies of mass‐dependent isotope fractionation. We suggest that the δ98/95Mo of the NIST SRM 3134 be defined as +0.25‰. The rationale is that the vast majority of published data are presented relative to reference materials that are similar, but not identical, and that are all slightly lighter than NIST SRM 3134. Our proposed data presentation allows a direct first‐order comparison of almost all old data with future work while referring to an international measurement standard. In particular, canonical δ98/95Mo values such as +2.3‰ for seawater and ?0.7‰ for marine Fe–Mn precipitates can be kept for discussion. As recent publications show that the ocean molybdenum isotope signature is homogeneous, the IAPSO ocean water standard or any other open ocean water sample is suggested as a secondary measurement standard, with a defined δ98/95Mo value of +2.34 ± 0.10‰ (2s).  相似文献   
65.
Silicon isotope determination of sulfur‐rich samples by MC‐ICP‐MS can be challenging because cation‐exchange chromatography used for Si purification does not efficiently remove anionic sulfur species. Results for pure Si standard solutions with addition of sulfate showed shifts of up to +1.04 ± 0.10‰ (2s) in δ30Si. Doping of both standard solutions and samples with S to a fixed S/Si ratio can eliminate the relative change in instrumental mass fractionation due to variable S/Si in samples and also boosts the relative sensitivity of Si by up to 66%. Moreover, Fe hydroxide precipitation during sample processing adsorbs Si resulting in isotopic fractionations. Tests using Fe‐rich samples showed that this could be a major factor for observed shifts in δ30Si. Acidification of the sample and standard solutions to a pH < 1 aggressively dissolved any Fe hydroxide precipitates, even in relatively Fe‐rich samples such as chondrite meteorites. The pH values of the sample solutions were subsequently adjusted to a range of 2–3 by adding ultra‐pure NaOH solutions. The combination of sulfur doping and the pH adjustment protocol ensured a full recovery of Si and proved to be an efficient and reliable method for Si isotope determination of S‐ and Fe‐rich materials.  相似文献   
66.
为提高桥梁变形预测的精度,探讨不同预测模型在桥梁变形预测中的效果,结合桥梁变形监测数据及组合预测思路,构建桥梁的MC误差修正优化组合预测模型。通过实例验证得出,组合预测较单项预测具有更高的预测精度及稳定性,其中以RBF神经网络组合的预测精度最高;同时,误差优化修正模型进一步减小了预测误差,优化后预测结果的相对误差期望值为0.86%,方差值为0.097 3 mm2,准确预测了桥梁变形,验证了该思路的有效性。  相似文献   
67.
激光拉曼法在高-过成熟页岩及煤成熟度评价中的应用   总被引:1,自引:1,他引:0  
激光拉曼光谱参数可以反映有机质成熟度信息,但在高-过成熟页岩及煤有机质中研究较少。本文通过激光拉曼、有机岩石热解和镜质组反射率实验,对南方海相筇竹寺组、龙马溪组页岩及沁水盆地、比德—三塘盆地无烟煤进行了有机质成熟度研究。利用拉曼图谱分峰拟合及前人的公式计算出拉曼计算反射率(RmcRo),并与热解峰温(Tmax)、实测镜质组反射率(Ro)进行相关性拟合。结果表明:页岩及无烟煤拉曼图谱楔形峰带、一级峰带(D峰和G峰)、二级峰带(S2、S3、S4峰)明显,RmcRo与Tmax、Ro相关性好,相关系数分别为0.9173和0.9614,RmcRo在成熟度评价中与Tmax、Ro评价结果具有一致性;与前人单点测试相比,激光拉曼多点测试可有效揭示页岩有机质成岩时期发生的不均等变化,对非均质性的反映更加准确,可靠性更高;页岩的RmcRo变异系数比煤的更大,表现出更强的有机质非均质性。研究成果可为高-过成熟页岩及煤有机质成熟度评价提供依据。  相似文献   
68.
利用MC-ICPMS精确测定143Nd/144Nd和Sm/Nd比值   总被引:43,自引:14,他引:43  
多收集器等离子体质谱(MCICPMS)用于分析SmNd同位素时,质量分馏系数(β)与同位素的质量数呈线性关系.可以采用两种方法进行质量分馏校正:双分馏系数内部校正法(DFIC)和单分馏系数外部校正法(SFEC).采用DFIC法,对国际标样ShinEtsuJNdi1和实验室标样NdGIG进行了为期五个月的143Nd/144Nd比值测量统计,结果分别为0.512120±0.000012(2σSD)、0.511532±0.000013(2σSD).采用SFEC法,对NdGIG标样的测量统计结果为0.511525±0.000015(2σSD).两种方法的测量结果在分析误差范围内与其推荐值或TIMS测量值完全一致.对加Ce和Sm的NdGIG混合溶液分别进行了Ce和Sm对143Nd/144Nd比值分析的干扰校正研究和Sm/Nd比值测量,结果显示,143Nd/144Nd比值分别与Ce/Nd、Sm/Nd测量值呈线性关系,Sm/Nd测量值与其质量比值亦呈很好的线性关系.这表明利用MCICPMS可以快速精确地测定存在Ce、Sm干扰的样品的143Nd/144Nd比值,同时可获得精确的Sm/Nd比值,而无需加入稀释剂.这就使直接测定地质样品的SmNd等时线年龄成为可能.  相似文献   
69.
In this study, we report both 143Nd/144Nd and 147Sm/144Nd values in twelve minerals (apatite, titanite, monazite and eudialyte) based on analyses over 4 years using LA‐MC‐ICP‐MS. The positive correlation between the measured βSm and βNd (r2 = 0.9981) over this time in our laboratory demonstrates the excellent long‐term stability of the method. Compared with the normal method, Sm and Nd signal intensities were improved by a factor of 2.9 with the use of X skimmer and Jet sample cones in combination with the addition of nitrogen at 3–6 ml min?1 to the central gas flow. The enhancement of signal intensity benefits the accurate in situ determination of the Sm‐Nd isotopes of samples poor in these elements. 143Nd/144Nd values were also determined in two manganese nodules and GSMC Co‐rich crust with low mass fractions of Nd (94–293 μg g?1). Generally, most of the obtained Sm‐Nd isotopic compositions in these geological materials are consistent with published values. ‘External reproducibility’ (2s) of 143Nd/144Nd and 147Sm/144Nd was typically better than 0.06‰ and 2.5‰, respectively, demonstrating that the Durango, Otter Lake, NW‐1 and MAD apatites, the Khan, and OLT‐1 titanites, MGMH#117531 monazite and LV01 eudialyte are promising candidate reference materials for in situ Sm‐Nd isotopic determinations. The Trebilcock, Mae Klang and 44069 monazites are only suitable for in situ Nd isotopic determinations because of their heterogeneous Sm/Nd compositions. The heterogeneous Sm‐Nd composition of titanite BLR‐1 demonstrates that it is not a suitable reference material for in situ Sm‐Nd isotopic determinations. Deep‐sea samples (NOD‐A‐1 and NOD‐P‐1 manganese nodule, GSMC Co‐rich crust) with low mass fractions of Nd also show homogenous Nd isotopic compositions. Sm‐Nd isotopic ratios of a monazite (MQG‐22) from the North China Craton were measured as a case study and gave a 147Sm‐143Nd isochron age of 1792 ± 35 Ma (MSWD = 3.2) consistent with the published metamorphic age of the host metasedimentary rocks. The results for both candidate reference materials and geological samples demonstrate that the in situ LA‐MC‐ICP‐MS analytical protocol described is feasible and robust for research in geological evolution.  相似文献   
70.
Magnesium isotopic compositions are reported for twenty‐four international geological reference materials including igneous, metamorphic and sedimentary rocks, as well as phlogopite and serpentine minerals. The long‐term reproducibility of Mg isotopic determination, based on 4‐year analyses of olivine and seawater samples, was ≤ 0.07‰ (2s) for δ26Mg and ≤ 0.05‰ (2s) for δ25Mg. Accuracy was tested by analysis of synthetic reference materials down to the quoted long‐term reproducibility. This comprehensive dataset, plus seawater data produced in the same laboratory, serves as a reference for quality assurance and inter‐laboratory comparison of high‐precision Mg isotopic data.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号