首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The USGS reference glasses GSA-1G, GSC-1G, GSD-1G, GSE-1G, BCR-2G, BHVO-2G and BIR-1G were investigated by different analytical techniques. All these materials have a geological (basaltic) matrix and are therefore useful in igneous geochemistry as matrix-matched reference materials for microanalytical techniques. The new GS glasses have trace elements in groups at concentration levels of about < 0.01, 5, 50 and 500 μg g-1. Their major element compositions have been determined by EPMA, and trace elements have been analysed by LA-ICP-MS and two isotope dilution techniques using TIMS and ICP-MS. EPMA and LA-ICP-MS analyses indicated that the USGS reference glasses are homogeneous at the μm to mm scale with respect to major (variations < 1-2%) and most trace elements (variations 1-4%). Trace element data obtained from the different analytical techniques agreed within an uncertainty of 1-5%, indicating that between method results are comparable. Therefore, the preliminary working values for the four USGS GS glasses calculated from these data have a low level of uncertainty.  相似文献   

2.
Data are reported for rare earth elements (REE) in three geological glass reference materials (BIR-1G, BHVO-2G and BCR-2G) using a UV (266 nm) laser ablation ICP-MS system and the classical (HF-HClO4) acid decomposition method, followed by conventional nebulisation ICP-MS. External calibration of laser ablation analyses was performed using NIST SRM reference materials with internal standardisation using 29Si and 44Ca. Replicate analyses of reference basaltic glasses yielded an analytical precision of 1-5% (RSD) for all the elements by solution ICP-MS and 1-8% (RSD) by laser ablation ICP-MS. The relative differences between the REE concentrations measured by solution and laser ablation ICP-MS compared with the reference values were generally less than 11 % for most elements. The largest deviations occurred for La determined by solution ICP-MS in BIR-1G. The results of both solution and laser ablation ICP-MS agreed well, generally better than 7%, with the exception of La, Pr and Sm in BIR-1G. The measured REE laser ablation data for BIR-1G, BHVO-2G and BCR-2G agreed with the previously published data on these basaltic reference glasses, within a range of 0-10% for most elements. No significant influences were observed for the predicted spectral interferences on some REE isotopes in the analysis of basaltic glasses.  相似文献   

3.
Sr isotopic compositions and Rb / Sr ratios of three USGS glasses (BHVO-2G, BIR-1G, BCR-2G) are identical to those of the original USGS reference materials. NKT-1G and TB-1G give values of 0.70351 and 0.70558, respectively. Pb isotopic ratios were measured by the standard-sample bracketing technique on an MC-ICP-MS, which give results that are comparable in accuracy and reproducibility to double spike analyses. However, assessment of the reproducibility of the technique is hampered by inhomogeneous contamination of all USGS reference materials analysed. This contamination is likely to be the reason why the USGS glasses do not all have the same Pb isotopic composition as their unfused originals. Powdered glasses, distributed for characterisation of the glasses by bulk analytical techniques, do not all have the same Pb isotopic compositions as the solid glass material, and can therefore not be used for this purpose.  相似文献   

4.
Nine rare earth elements have been determined by inductively coupled plasma spectrometry (ICP) in eight USGS reference samples, MAG-1, SCo-1, SDC-1, BIR-1, DNC-1, W-2, BCR-1 and BHVO-1 and in the ANRT Glauconite, GL-O. Along with these new data, updated compilations are presented for these samples. Good agreement is observed between the present work and the compiled values.  相似文献   

5.
We present data for the concentrations of eleven rare earth elements (La, Ce, Pr, Nd, Sm, Eu, Gd, Dy, Er, Yb, Lu) in eleven international geochemical reference materials obtained by isotope dilution multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). We have analysed both rock powders and synthetic silicate glasses, and the latter provide precise data to support the use of these as reference materials for in situ trace element determination techniques. Our data also provide precise measurements of the abundance of mono-isotopic Pr in both glasses and powders, which allows more accurate constraints on the anomalous redox-related behaviour of Ce during geochemical processes. All materials were analysed in replicate providing data that typically reproduce to better than one percent. Sm/Nd ratios in all these materials also reproduce to better than 0.2% and are accurate to < 0.2% and can thus be used as calibrants for Sm-Nd geochronology. Our analyses agree well with existing data on these reference materials. In particular, for NIST SRM 610, USGS BHVO-2, AGV-1 and AGV-2, our measured REE abundances are typically within < 2% (and mostly 1%) of REE concentrations previously determined by isotope dilution analysis and thermal ionisation mass spectrometry, consistent with the higher degree of precision and accuracy obtained from isotope dilution techniques. Close agreement of results between basaltic glass reference materials USGS BHVO-2G and BCR-2G and the BHVO-2 and BCR-2 powders from which they were created suggests that little fractionation, concentration or dilution of REE contents occurred during glass manufacture.  相似文献   

6.
Different batches of the new US Geological Survey (USGS) reference materials (RMs) BCR-2, BHVO-2, AGV-2, DTS-2 and GSP-2 and the original USGS RMs BCR-1, BHVO-1, AGV-1, DTS-1 and GSP-1 have been analysed by isotope dilution using thermal ionisation mass spectrometry (ID-TIMS) and by multi-ion counting spark source mass spectrometry (MIC-SSMS). The concentrations of K, Rb, Sr, Ba and the rare earth elements were determined with overall analytical uncertainties of better than 1% (ID-TIMS) and 3% (MIC-SSMS). The analyses of different aliquots and batches of BCR-2, BHVO-2, AGV-2 and GSP-2, respectively, agree within 1%, i.e. approximately the analytical uncertainties of the data. This indicates an homogeneous distribution of the trace elements in these RMs. Differences in element concentrations of up to 17% in different aliquots of the depleted RM DTS-2 are outside the analytical uncertainty of our data. They may be attributed to a slightly heterogeneous distribution of trace elements in this dunite sample. Our trace element data for BCR-2, BHVO-2, AGV-2 and GSP-2 agree within about 3% with preliminary reference values published by the USGS. They also agree within 1-6% with those of the original RMs BCR-1, BHVO-1, AGV-1 and GSP-1. Large compositional differences are found between DTS-2 and DTS-1, where the concentrations of K, Rb, Sr and the light REE differ by factors of 2 to 24.  相似文献   

7.
Four mafic USGS rock standards (BHVO-1, BIR-1, DNC-1, BCR-1) were analyzed at three sample sizes (1, 5, and 10 g) for gold by neutron activation analysis subsequent to fire-assay concentration. The results indicate that large samples, in the order of 10 g, are required to produce consistent results, although analyses of variance indicate that sample sizes of 5 g may be used effectively. The analysis of 1 g samples resulted in a large range of values and high standard deviations. BCR-1 was found to be the most homogeneous of the four standards for gold, followed in decreasing order by BIR-1, DNC-1, and BHVO-1. Data for Ir in BIR-1 and DNC-1 are also presented.  相似文献   

8.
全岩样品主元素和微量元素的准确测试是地球科学研究的重要手段和依据.传统溶液进样ICP-MS元素测试方法制样和测试所需周期较长(两周以上).相对溶液进样法而言,激光剥蚀系统与ICP-MS联用测试全岩粉末熔融玻璃的方法可以大大地提高测试效率.在前人研究基础上,针对前人熔融制样中Pb、Zn元素的严重丢失问题,研究了Pb、Zn...  相似文献   

9.
Molybdenum concentrations in eleven USGS geochemical reference materials AGV-1, BCR-1, BHVO-1, BIR-1, DNC-1, DTS-1, G-2, GSP-1, MAG-1, PCC-1 and W-2 were measured by isotope dilution thermal ionisation mass spectrometry (ID-TIMS). In every case but one, the concentrations determined in this study were significantly lower than the current consensus values. Molybdenum concentrations determined by ID-TIMS are inherently more accurate and precisions may be up to an order of magnitude higher than those measured by other analytical techniques.  相似文献   

10.
We have measured 87Sr/86Sr and 143 Nd/144 Nd isotope ratios in different batches and aliquots of the new US Geological Survey (USGS) reference materials (RMs) BCR-2, BHVO-2, AGV-2 and GSP-2 and the original USGS RMs BCR-1, BHVO-1, AGV-1 and GSP-1 by thermal ionisation mass spectrometry. In addition, we also analysed the eight Max-Planck-Institut-Dingwell (MPI-DING) reference glasses. Nearly all isotope ratios obtained in the different aliquots and batches agree within uncertainty limits indicating excellent homogeneity of the USGS powders and the MPI-DING glasses. With the exception of GSP-2, the new USGS RMs are also indistinguishable from the ratios found in the original USGS RMs (87Sr/86Sr: 0.704960, 0.704958 (BCR-1, -2), 0.703436, 0.703435 (BHVO-1, -2), 0.703931, 0.703931 (AGV-1, -2); 143 Nd/144 Nd: 0.512629, 0.512633 (BCR-1, -2), 0.512957, 0.512957 (BHVO-1, -2); 0.512758, 0.512755 (AGV-1, -2)). This means that for normalisation purposes in Sr and Nd isotope geochemistry BCR-2, BHVO-2 and AGV-2 can well replace BCR-1, BHVO-1 and AGV-1 respectively.  相似文献   

11.
Inductively coupled plasma-mass spectrometry is well suited for the precise, accurate and rapid determination of rare earth elements in most geological samples. However, determination of rare earth elements in certain mantle-derived materials, without applying preconcentration techniques, remains problematical due to low natural concentrations (generally < 1 ng g−1). Consequently, USGS reference materials DTS-1 (a dunite) and PCC-1 (a partially serpentinized harzburgite) have only suggested rather than recommended values for the rare earth elements in reference material compilations. We compared results obtained using two ICP-MS instruments: a U-5000AT ultrasonic nebuliser coupled to a PQ2+ quadrupole ICP-MS and an ELEMENT sector field ICP-MS equipped with a MCN-6000 microconcentric desolvating nebuliser, with the suggested literature values for these two reference materials. Precision and accuracy of analytical methods employed by both instruments were demonstrated by excellent relative standard deviations (< 2%) and inter-laboratory agreement (< 5%) for numerous analyses of BHVO-1 and BIR-1, which are well established with rare earth elements contents at the μg g−1 level. Repeat analyses of DTS-1 and PCC-1 at each laboratory indicate that each method is generally precise to better than 5% at sub-g g−1 levels. Furthermore, values from both instruments generally agree to within 10%. Our DTS-1 and PCC-1 values agree reasonably well with selected data reported in the literature (except for Ce and Sm in DTS-1) but exhibit poorer agreement with reported compilation values. With the demonstrated level of precision and accuracy, we contend that these new values for DTS-1 and PCC-1, generated by two different instruments, are the best estimates of the true whole-rock composition of these samples reported to date.  相似文献   

12.
Elemental composition data on eight older (AGV-1, BCR-1, DTS-1, G-1, G-2, GSP-1, PCC-1 and W-1) and three newer (BIR-1, DNC-1 and W-2) USGS rock standards have been collected from institutional reports and journal articles from 1972–1981. This collection was combined with data from previous compilations and "consensus values" for up to 79 elements determined by comparing overall means, medians, and individual means based on analytical techniques.  相似文献   

13.
We present a concerted international effort to cross-calibrate five synthetic Th isotope reference materials (UCSC Th "A", OU Th "U", WUN, IRMM-35 and IRMM-36), and six rock reference materials (UCSC TML, Icelandic ATHO, USGS BCR-2, USGS W-2, USGS BHVO-2, LV18) using multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). We then compare our new values with a compilation of literature mass spectrometric data for these reference materials and derive recommended "consensus"230Th/232Th values for each. We also present isotope dilution U and Th concentration data for four rock reference materials (UCSC TML, Icelandic ATHO, USGS BCR-2, USGS W-2).  相似文献   

14.
The concentrations of 26 elements have been investigated in seven BCS certified reference samples using three varieties of neutron activation analysis. The ANRT granite GS-N was used as the comparator reference material while the USGS basalt BHVO-1 and the GIT-IWG basalt BE-N were analysed concurrently to assess the analytical accuracy.  相似文献   

15.
The authors measured Pb isotope compositions of seven USGS rock reference standards, i.e. AGV-1, AGV-2, BHVO-1, BHVO-2, BCR-2, BER-1/1 and W-2, together with NBS 981 using a micromass isoprobe multi-collector inductively-coupled plasma mass spectrometer (MC-ICP-MS) at the University of Queensland. 203Tl-205Tl isotopes were used as an internal standard to correct for mass-dependant isotopic fractionation. The results for both NBS 981 and USGS rock standards AGV-1 and BHVO-1 are comparable to or better than double- and triple-spike TIMS (thermal ionization mass spectrometry) data in precision. The data for BHVO-2 and, to a lesser extent, AGV-2 and BCR-2 are reproducibly higher for 206Pb/204Pb, 207Pb/204Pb and 208Pb/204Pb than double-spike TIMS data in the literature. The authors also obtained the Pb isotope data for BIR-1/1 and W-2, which may be used as reference values in future studies. It is found that linear correction for Pb isotopic fractionation is adequate with the results identical to those corre  相似文献   

16.
Data were obtained for rubidium in six geological reference materials by isotopic dilution thermal ionisation mass spectrometry (ID-TIMS) and wavelength dispersive X-ray fluorescence spectrometry (WD-XRF). The results found by one technique compare very well with the other within the respective analytical uncertainties and are also in good agreement with data from previously published values. The particular case of low Rb determinations in reference sample BIR-1 is discussed.  相似文献   

17.
Data on thirty-four minor and trace elements including all rare earth elements (REE) are reported for two kimberlitic international reference materials (SARM-39, MINTEK, RSA and MY-4, IGEM, Russia) by inductively coupled plasma-mass spectrometry (ICP-MS), some of them for the first time. Four digestion techniques (open acid, closed vessel acid, microwave and lithium metaborate fusion digestion) were used for the decomposition of samples for analysis by ICP-MS. Three other reference materials (USGS BHVO-1, CRPG BR-1 and ANRT UB-N) were analysed simultaneously using the same analytical methodology to assess the precision and accuracy of the determinations. The data obtained in this study compare well with working values wherever such values are available for comparison. Though open acid digestion was found to be very rapid, effective and convenient for the determination of several trace elements in kimberlitic samples, recoveries for heavy rare earth elements (HREE) were lower than the respective recoveries obtained by the other decomposition techniques used. The precision obtained was better than ± 6% RSD in the majority of cases with comparable accuracy. Chondrite-normalised plots of each RM for all the digestion techniques were smooth. The new data reported on the two kimberlitic reference materials make these samples useful for future geochemical studies of kimberlitic rocks.  相似文献   

18.
The Li isotope ratios of four international rock reference materials, USGS BHVO-2, GSJ JB-2, JG-2, JA-1 and modern seawater (Mediterranean, Pacific and North Atlantic) were determined using multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). These reference materials of natural samples were chosen to span a considerable range in Li isotope ratios and cover several different matrices in order to provide a useful benchmark for future studies. Our new analytical technique achieves significantly higher precision and reproducibility (< ± O.3%o 2s) than previous methods, with the additional advantage of requiring very low sample masses of ca . 2 ng of Li.  相似文献   

19.
We have developed a rapid and accurate method to determine Zr, Nb, Hf and Ta (denoted as HFSE) in geological samples by inductively coupled plasma-mass spectrometry fitted with a flow injection system (FI-ICP-MS). The method involves sample decomposition by HF followed by HF dissolution of HFSE coprecipitated with insoluble M and Ca fluoride residues formed during the initial HF attack. This HF solution was directly nebulized into an ICP mass spectrometer. An external calibration curve method and an isotope dilution method (ID) were applied for the determination of Nb and Ta, and of Zr and Hf, respectively. Recovery yields of HFSE were > 96% for peridotite, basalt and andesite compositions, apart from Zr and Hf for peridotite (> 85%). No matrix effects for either signal intensities of HFSE or isotope ratios of Zr and Hf were observed in basalt, andesite and peridotite solutions down to a dilution factor of 100. Detection limits in silicate rocks were 40, 2, 1 and 0.1 ng g-1 for Zr, Nb, Hf and Ta, respectively. This technique required only 0.1 ml of sample solution, and thus is suitable for analysing small and/or precious samples such as meteorites, mantle peridotites and their mineral separates. We also present newly determined data for the Zr, Nb, Hf and Ta concentrations in USGS silicate reference materials DTS-1, PCC-1, BCR-1, BHVO-1 and AGV-1, GSJ reference materials JB-1, -2, -3, JA-1, -2 and -3, and the Smithsonian reference Allende powder.  相似文献   

20.
Trace amounts (from nanogram to microgram levels) of bromine and iodine were determined by inductively coupled plasma-mass spectrometry (ICP-MS) in twenty-three geochemical reference materials issued by the GSJ, USGS, IAEA etc. The pyrohydrolysis technique was used to separate bromine and iodine from samples analysed in the form of powder. The accuracy and precision of the experimental values were assessed by the comparative analysis of well established reference materials such as USGS AGV-1, BCR-1 and IGGE GBW07312. The measured values agreed well with reported values within a 10% error range. We also report reliable new data for these elements in these geochemical reference materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号