首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Vertical electrical resistivity soundings were conducted in order to delineate groundwater potential aquifers in Peddavanka watershed, which is a catchment of about 398 km2 in Anantapur District, Andhra Pradesh, India. The main lithologic units in the watershed are quartzite, limestone, shale, and alluvium. Ninety-nine vertical electrical soundings were conducted using the Schlumberger configuration, covering the entire watershed. The data were interpreted with the help of master curves and auxiliary point charts. Interpretations of VES were used to generate a top layer apparent resistivity contour map and longitudinal conductance map. Isoresistivity contour maps were prepared and interpreted in terms of resistivity and thickness of various sub-surface layers using computer software (SURFER), and isocontour diagrams depicting the depth to bedrock were prepared. Resistivity results were correlated with the existing lithology. Based on the depth to bedrock, the thickness of the saturated layer and the resistivity of the second layer, a groundwater potential map has been prepared, in which good, moderate, and poor zones are classified. The study reveals that the weathered and fractured portions in shale and limestone that occur in the southernmost and central portions of the watershed area constitute the productive water-bearing zones categorized as good groundwater potential aquifers.  相似文献   

2.
Hydrogeophysical investigations of the Pleistocene aquifer at the Kom Hamada area, Egypt, have been conducted to determine the characteristics of groundwater. The main water-bearing formations in the study area are composed of Quaternary deposits. Water samples were taken and chemically analyzed at 29 sites. The constructed iso-salinity contour map of the study area showed an increase in salinity from 451.75 mg/l at eastern parts to 1,091.85 mg/l at western parts. The groundwater of the study area showed a hydrochemical evolution from Ca–HCO3 at the eastern side to Na–Cl at the western side. Some of groundwater constituents have high concentration values exceeding the safe limit for drinking. Eighteen vertical electrical soundings (VES) were conducted in the study area. These soundings were conducted near existing wells to obtain layer parameters of the various penetrated layers and to calculate the petrophysical characteristics of the aquifers. The resistivity of the first water-bearing layer ranges between 34 and 47 Ω m. The thickness of this layer ranges between 26 and 79 m. This layer represents the first aquifer, where it is followed by another water-bearing layer with resistivity ranges between 29 and 62 Ω m and extends downward. The two aquifers are hydraulically connected. Variation of the resistivities of these two water-bearing layers is mainly due to the lithological variation. The resistivity values along with the TDS values of the two water-bearing layers indicate fresh to brackish water types.  相似文献   

3.
乌蒙山贫困缺水区水资源严重缺乏,找水需求大、难度大。为确定了ZK12探采结合井位置,本文首先分析了工区找水环境因素的地层时代、含水介质类型、构造背景、水源条件和水动条件等5个条件;其次,对富水特征的含水岩组、蓄水构造和富水地貌进行研究;最后,重点分析地球物理特征找水因素,介绍了视电阻率联合剖面法、大地电磁测深法、瞬变电磁法、激电测深和地球物理测井等“多方法”应用效果,通过视电阻率、视极化率、衰减度、半衰时等“多参数”,确定断层裂隙水的地球物理特征,建立由浅入深的“多层次”地球物理模式。最终,创新性提出了乌蒙山连片贫困缺水区重点村镇的“多方法、多参数、多层次”地球物理找水模式,克服单一物探方法找水的局限性,精准定井位,对地下水勘查起到示范作用。   相似文献   

4.
Integrated geophysical techniques including resistivity image, vertical electrical sounding (VES), and seismic refraction have been conducted to investigate the Wadi Hanifah water system. The groundwater in Wadi Hanifah has problems caused by the high volumes of sewage water percolating into the ground. The combination of VES, resistivity image, and seismic refraction has made a valuable contribution to the identification of the interface between the contaminated and fresh water in Wadi Hanifah area. The contaminated groundwater has lower resistivity values than fresh groundwater due to the higher concentration of ions which reduces the resistivity. Resistivity image and sounding in this area clearly identified the nature of the lithological depth and proved useful at identifying water-bearing zones. Fresh groundwater was found in the study area at a depth of 100 m within the fractured limestone. Water-bearing zones occur in two aquifers, shallow contaminated water at 10 m depth in alluvial deposits and the deeper fresh water aquifer at a depth of about 100 m in fractured limestone. The interface between the contaminated water (sanitary water) and fresh water marked out horizontally at 100 m distance from the main channel and vertically at 20 m depth.  相似文献   

5.
Geoelectrical surveys of the Nanjido waste landfill in Seoul,Korea   总被引:3,自引:0,他引:3  
Electrical surveys have routinely been taken to map and monitor groundwater contamination. In 1994-1996, various electrical surveys were applied to investigate contaminant distributions in the ground at the Nanjido landfill. The geophysical survey data were compared with other available information, particularly boring data. Interpretations of electrical survey data show low resistivity zones below 10 ohm-m which appear to be zones fully saturated with leachate. Annual variations of resistivity anomalies clearly indicate that resistivities and thicknesses of layers contaminated by leachate become lower and thicker in and around the Nanjido landfill during one year. In particular, mean thickness of saturated layers with leachate increased by about 3-6 m/year and the resistivity of bedrock decreased. It seems obvious that ground contamination by leachate is in progress. In the area northeast of the landfill, no evidence of bedrock contamination is indicated. Soundings made at one year intervals in this area do not show any evidence of further ground contamination by leachate. From these results, it appears that contamination of the weathered zone and bedrock is in progress mainly southwest of the Nanjido landfill.  相似文献   

6.
覆盖区活动断裂探测往往需要选择合理的物探方法以确定断裂位置,高密度电法具有数据采集效率高、探测精度高等优点,已在覆盖区活动断裂探测中得到广泛应用。本文利用高密度电法在长白山玄武岩覆盖区进行断裂探测,对实测数据进行反演,分析了NE向鸭绿江断裂带抚松段西支断裂在松江河镇北东侧第二松花江畔的展布形态,同时,利用钻探对断裂探测结果加以验证。视电阻率剖面表明完整基岩主要呈现出高阻值,断裂破碎带由于含水丰富则呈现为低视电阻率异常值。而断层内较为破碎,且富含水,故在视电阻率剖面上呈现明显低阻异常,这些结果能够与钻孔揭露地层实物资料较好对应。钻孔的断层样品14C测年结果显示,西支断裂在松江河镇兴隆林场为晚更新世活动断裂。  相似文献   

7.
Integrated geoelectrical and hydrochemical surveys were used to investigate and delineate different types of groundwater in the Kuala Selangor alluvial aquifer. Previous hydrogeological borehole investigation showed that this aquifer contains several types of groundwater in relation to its salinity. The high salinity of the groundwater in some areas is believed to be due to either saltwater intrusion from the nearby sea or river infiltration during high tide season. The vertical electrical sounding (VES) method was employed to study and map the subsurface variation of resistivity in the area. For each sounding measurement, a total spread length of 300 m was obtained with a vertical depth penetration of about 60 to 75 m. Chemical analysis of the groundwater samples taken from both shallow and deep boreholes was carried out for the water quality determination. A total of 45 VES stations were succesfully established along three parallel roads with a direction almost perpendicular to the coastal line. The distance between stations varies from 1 to 2 km with a maximum length of about 60 km surveyed line. Results of the vertical electrical soundings as well as the hydrochemistry of the groundwater samples show that the soil and groundwater in the study area can be grouped into fresh and brackish water zones. The subsurface resisitivity sections derived from the VES study suggest that the area is dominated by brackish soil and groundwater zones, especially in the area towards the coast. This result appears to agree well with the groundwater pumped from boreholes scattered around in the area. Water drawn from boreholes near the coast showed higher salinity compared to the water pumped from inland boreholes. Chloride values greater than 250 mg/L are considered to represent the brackish zones whilst values less than 250 mg/L represents zones of fresh soil and groundwater.  相似文献   

8.
Integrated surface electrical resistivity and electromagnetic (EM) surveys were conducted in a hard-rock terrain of Southwestern Nigeria in the vicinity of active oxidation sewage treatment ponds. The aim was to detect soil contamination due to the spread of sewage effluent, locate possible leachate plumes and conductive lithologic layers, and access the risk of groundwater pollution in the vicinity of the sewage-ponds. Dipole–dipole resistivity profiling and very low frequency (VLF) data were acquired at 10-m intervals along five 200-m long east-west geophysical traverses. Resistivity sections obtained revealed four subsurface geologic layers comprised of lateritic clay, clayey sand/sand, weathered/fractured bedrock, and competent bedrock. A distinct low resistivity zone corresponding to the contamination plume (labeled B) was delineated from all the resistivity sections. This low zone extends into the weathered bedrock and possibly suggests contamination of this layer. The filtered real component of the processed VLF data detected three distinct anomaly zones that are representative of fractured zones filled with conductive fluids and/or lithologic boundaries that possibly serve as conduits for the movement of contaminated effluents. The results obtained from the two methods suggest possible contamination of the subsurface soil layers and groundwater in the vicinity of the sewage-ponds. The existence of this contaminated plume poses a serious threat to the ecosystem and health of the people living in the vicinity of the sewage-ponds.  相似文献   

9.
Coastal aquifers can become polluted due to natural and human activities, such as intrusion of saline water, discharge of effluents in industrial areas and chemical weathering of natural geological deposits. The present study is aimed mainly at understanding the geophysical and chemical characteristics of groundwater near Tuticorin, Tamilnadu, India by studying the electrical resistivity distribution of the subsurface groundwater by applying the Schlumberger vertical electrical sounding (VES) technique followed by chemical analysis of water samples. A total of 20 VES soundings were carried out to understand the resistivity distribution of the area and 21 water samples were collected to analyze the chemical quality. The interpretation and analysis of the results have identified different hydrogeologic behaviors, a highly saline coastal aquifer and freshwater locations. The results obtained from geophysical and geochemical sampling are in good agreement with each other. The approach shows the efficacy of the combination of geophysical and geochemical methods to map groundwater contamination zones in the study area.  相似文献   

10.
A geoelectrical resistivity survey using vertical electrical sounding (VES) was conducted at Chaj Doab (land between rivers Jhelum and Chenab, Pakistan) and Rachna Doab (land between rivers Chenab and Ravi, Pakistan), with the objective of investigating groundwater conditions. A total of 90 sites were selected with 43 sites in Chaj and 47 sites in Rachna Doabs. The resistivity meter (ABEM Terrameter SAS 4000, Sweden) was used to collect the VES data by employing a Schlumberger electrode configuration, with half current electrode spacings (AB/2) ranging from 2 to 180 m and the potential electrode (MN) from 1 to 40 m. The field data were interpreted using the Interpex IX1D computer software and the resistivity versus depth models for each location was estimated. The outputs of subsurface layers with resistivities and thickness presented in contour maps and 3-D views by using SURFER software were created. A total of 102 groundwater samples from nearby hydrowells at different depths were collected to develop a correlation between the aquifer resistivity of VES and the electrical conductivity (EC) of the groundwater and to confirm the resulted geophysical resistivity models. From the correlation developed, it was observed that the groundwater salinity in the aquifer may be considered low and so safe for irrigation if resistivity >45 Ω m, and marginally fit for irrigation having resistivity between 25 and 45 Ω m. The study area has resistivities from 3.9 to 2,222 Ω m at the top of the unsaturated layer, between 1.21 and 171 Ω m, in the shallow aquifers, and 0.14–152 Ω m in the deep aquifers of the study area. The results indicate that the quality of groundwater is better near the rivers and in the shallow layers compared to the deep layers.  相似文献   

11.
Geological transition zones are noted to be problematic in groundwater potential and development, due to their erratic and complex nature as well as characteristic of the subsurface lithologies. There were several occurrences of reported borehole failures and dry wells in these zones in Nigeria as a result of very scanty information that could serve as database for studying its groundwater potential. This study was therefore designed to generate hydrogeophysical data that could serve as baseline information on the groundwater potential in the study. In addition, to also delineate various subsurface lithologies present. Electrical resistivity survey for geophysical investigation was carried out using vertical electrical sounding (VES) technique. A total of 150 VES stations were purposively probed using Schlumberger electrode array. The interpreted data were used to produce geoelectric subsurface lithologies and to draw the geological section across the entire area. Various subsurface lithologies with their resistivities (Ωm) were delineated for basement complex (BC), transition zone (TZ), and sedimentary terrain (ST). In BC were topsoil, weathered zone, and fresh bedrock and in TZ were topsoil, sandy, laterite/clay, dry sand, sandstone, and fresh bedrock delineated while in the ST, topsoil, lateritic and sandy clay, dry sand, and the sandstone were delineated. In conclusion, the groundwater potential of the study area is largely been affected by the topography and the nature/composition of the Abeokuta Group that underlie the sedimentary part of the study area and the presence of thick laterite/clay unit of the basement complex portion of the study area.  相似文献   

12.
In this paper, the application of 2D and 3D electrical resistivity methods in geotechnical investigations is explored through a case study in Northern Greece. These two methods were employed at a lignite surface mining operation where fracture zones and discontinuities have been recently observed close to the pit boundaries. The main aim of the geophysical survey was to estimate the inclination of the contact between the Neogene and Schist/Carbonate formations near the southern limits of the pit, as well as to estimate the thickness of the carbonate rocks on top of the Schist formations to evaluate the stability of the southern slopes. Synthetic data were initially generated to help plan an efficient electrical tomography survey, in a region with complex geology and irregular terrain. Three configurations (Wenner–Schlumberger and dipole–dipole or pole–dipole) proved essential in such conditions and helped improving the resolution of the resistivity section. The sections were then calibrated by boreholes. Finally, the geophysical survey provided invaluable data regarding the geometry of the bedrock and possible faults, which was essential for the slope stability calculations.  相似文献   

13.
Geoelectrical resistivity method involving vertical electrical sounding (VES) was carried out in a sedimentary environment to determine the suitability of the method for sub-surface groundwater investigations. The EC and TDS hydrochemical data in the study area clearly showed the influence of seawater intrusion. The abundance of the major cations and anions are in the following order, Na+ > Ca2+ > Mg 2+ > K+ = Cl- > HCO3- > SO42- > CO3 > NO3 > PO4. Results suggest that the groundwater in this study area is very hard and alkaline in nature. As indicated by Piper trilinear diagram, NaCl and Ca2+ - Mg2+–Cl- - SO42- facies are the dominant hydrochemical facies in the groundwater of Pearl city. The VES method by Schlamberger electrode array was applied in 12 locations, which is expected to represent the whole area. The resistivity meter (aquameter CRM 5OO) was used to collect the VES data by employing a Schlumberger electrode configuration, with half current electrode spacing (AB/2) ranging from 2 to 180 m and the potential electrode (MN) from 1 to 50 m. The resistivity data is then interpreted by WINSEV 1-D inversion program geoelectric software to entirely describe the aquifer system as well as the occurrence of groundwater. The outputs of sub-surface layers with resistivities and thickness presented in contour maps and 2-D views by using SURFER software were created. Accordingly, three zones with different resistivity values were detected, corresponding to three different formations: (1) a transition zone of sandy soil (aeolian deposits) thick formation, (2) strata’s saturated with fresh groundwater in the east disturbed by the presence of sandy shell limestone horizons, (3) a water-bearing formation in the west containing low saltwater horizons. The bedrock is encountered at an average depth of 95m. This study indicates that the groundwater reservoirs are mainly confined to the alluvial aquifer.  相似文献   

14.
Recently, the deterioration of water quality in the coastal zones of Lekki Peninsula area of Lagos due to saltwater infiltration into the freshwater aquifer has become a major concern. With the aim of providing valuable information on the hydrogeologic system of the aquifers, the subsurface lithology and delineating the groundwater salinity, vertical electrical resistivity (VES) sounding survey was carried out utilizing surface Schlumberger electrode arrays, and electrode spacing varying between 1 and 150 m. The DC resistivity surveys revealed significant variations in subsurface resistivity. Also, the VES resistivity curves showed a dominant trend of decreasing resistivity with depth (thus increasing salinity). In general, the presence of four distinct resistivity zones were delineated viz.: the unconsolidated dry sand (A) having resistivity values ranging between 125 and 1,028 Ωm represent the first layer; the fresh water-saturated soil (zone B) having resistivity values which correspond to 32–256 Ωm is the second layer; the third layer (zone C) is interpreted as the mixing (transition) zone of fresh with brackish groundwater. The resistivity of this layer ranges from 4 to 32 Ωm; while layer four (zone D) is characterized with resistivities values generally below 4 Ωm reflecting an aquifer possibly containing brine. The rock matrix, salinity and water saturation are the major factors controlling the resistivity of the formation. Moreover, this investigation shows that saline water intrusion into the aquifers can be accurately mapped using surface DC resistivity method.  相似文献   

15.
Two geophysical techniques were integrated to map the groundwater aquifers on complex geological settings, in the crystalline basement terrain in northeast Nuba Mountains. The water flow is structurally controlled by the northwest–southeast extensional faults as one of several in-situ deformational patterns that are attributed to the collision of the Pan-African oceanic assemblage of the Nubian shield against the pre-Pan African continental crust to the west. The structural lineaments and drainage systems have been enhanced by the remote sensing technique. The geophysical techniques used are: vertical electrical soundings (VES) and electrical resistivity tomography (ERT), in addition to hydraulic conductivity measurements. These measurements were designed to overlap in order to improve the producibility of the geophysical data and to provide a better interpretation of the hydrogeological setting of the aquifer complex structure. Smooth and Block inversion schemes were attempted for the observed ERT data to study their reliability in mapping the different geometries in the complex subsurface. The VES data was conducted where ERT survey was not accessible, and inverted smoothly and merged with the ERT in the 3D resistivity grid. The hydraulic conductivity was measured for 42 water samples collected from the distributed dug wells in the study area; where extremely high saline zones were recorded and have been compared to the resistivity values in the 3D model.  相似文献   

16.
Sinkhole collapse is one of the main limitations in the development of karst areas, especially where bedrock is covered by unconsolidated material. Studies of sinkhole formation have shown that sinkholes are likely to develop in cutter (enlarged joint) zones as a result of subterranean erosion by flowing groundwater. Ground-penetrating radar (GPR) and electrical resistivity imaging or tomography (RESTOM) are well suited to mapping sinkholes because of the ability of these two techniques for detecting voids and discriminating subtle resistivity variations. Nine GPR profiles and two-dimensional electrical resistivity tomography have been applied, with relative success, to locate paleo-collapses and cavities, and to detect and characterize karst at two sinkhole sites near Cheria City where limestone is covered by about 10 m of clayey soils. The survey results suggest that GPR and RESTOM are ideal geophysical tools to aid in the detection and monitoring of sinkholes and other subsurface cavities.  相似文献   

17.
Surface geophysical methods were used to determine the locations of fracture zones in part of the hard rock area in Sonebhadra District of Uttar Pradesh, India. The survey comprises three DC resistivity profile using the gradient profiling technique and ten very low frequency electromagnetic (VLF-EM) traverses profiles. The methods were used over survey lines extending between 200 and 400 m; the results were correlated to locate fracture zones for the purpose of groundwater exploration. Qualitative interpretation of the VLF-EM was carried out using Fraser and Karous–Hjelt filters. The result of the interpretation revealed a number of subsurface zones with high real component current density that defines the potential subsurface features (probably fracture zones). The subsurface feature concurred with the low resistive zones indentified from the gradient resistivity profiling. The zones where further inferred quantitatively using data obtained from DC resistivity sounding at some selected anomalous points. The result obtained proves the efficiency of integrating both methods in detecting fractures zones in hard rock area.  相似文献   

18.
The presence of natural voids and cavities in subsurface karstic limestones causes severe problem for civil engineering and environmental management.The presence of such features hinders the extension of urbanizations particularly in the new metropolitan.The eastern part of Saudi Arabia contains various types of karstic limestone,sinkholes,solution cavities and voids.In this context,geophysical methods particularly electrical resistivity technique is used as a cost-effective solution for investigating subsurface caves,voids,and shallow weathered zones.2-D electrical resistivity data sets have been acquired along seven profiles in the new urbanization at Al Hassa area.Data processing has been carried out taking into consideration the response of synthetic models,which simulates physical models of the most common karstic features in the area.The results are very useful to determine the extension of shallow weathered zones and to locate different cavities underneath them.The hard limestone bedrock can also be detected and traced along the surveyed profiles.  相似文献   

19.
Geophysical and hydrochemical borehole-logging techniques were integrated to characterize hydraulic and hydrogeochemical properties of the Chalk aquifer at boreholes in Berkshire, UK. The down-hole measurements were made to locate fissures in the chalk, their spatial extent between boreholes, and to determine the groundwater chemical quality of the water-bearing layers. The geophysical borehole logging methods used were caliper, focused resistivity, induction resistivity, gamma ray, fluid temperature, fluid electrical conductivity, impeller and heat-pulse flowmeter, together with borehole wall optical-imaging. A multiparameter data transmitter was used to measure groundwater temperature, electrical conductivity, dissolved oxygen, pH, and redox potential of the borehole fluid down-hole. High permeability developed at the Chalk Rock by groundwater circulation provides the major flow horizon at the Banterwick Barn study site and represents a conduit system that serves as an effective local hydraulic connection between the boreholes. The Chalk Rock includes several lithified solution-ridden layers, hardgrounds, which imply a gap in sedimentation possibly representing an unconformity. Lower groundwater temperature, high dissolved-oxygen content, and flowmeter evidence of preferential groundwater flow in the Chalk Rock indicated rapid groundwater circulation along this horizon. By repeating the logging at different times of the year under changing hydraulic conditions, other water-inflow horizons within the Chalk aquifer were recognized. Electronic Publication  相似文献   

20.
Geoelectrical resistivity investigation using Vertical Electrical Sounding (VES) technique was conducted at Port Blair, South Andaman Island, to locate the fractures in different formations and to decipher its groundwater potential. A total of 40 VES were carried out covering the entire study area using Schlumberger electrode configuration out of which 34 VES fall in Andaman Flysch formations and the remaining VES in Ophiolite formations. The interpreted resistivity results were integrated with nine borehole lithologs for the subsurface analysis. The combination of VES with borehole litholog data has provided a close correspondence on subsurface hydrogeological conditions. The interpreted VES data of various formations showed drastic variations in the resistivity ranging from higher in Ophiolite, moderate in Andaman Flysch and very low in valleys of Andaman Flysch formations. The study further revealed that the weathered and fractured volcanics of Ophiolite groups of rocks and sandstone that occur in the Andaman Flysch formations constitute the productive water bearing zones categorized as good groundwater potential zone. Based on the geoelectrical parameters, viz., thickness of layers and the layer resistivity values, a groundwater potential map was prepared, in which good, moderate, and poor groundwater zones were demarcated. Further, numerical, spatial and litho-geoelectric models of resistivity were analyzed in terms of groundwater potential and these models have thus enabled to prepare a comprehensive groundwater development and management plans proving its efficacy in this art of exploratory investigations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号