首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
By using a high-speed video camera system (1000 frames s− 1) in correlation with fast and slow antenna systems, the negative cloud-to-ground (CG) flashes that struck the ground with more than one termination have been analyzed. This kind of stroke, named as multiple-ground terminations stroke (MGTS), was produced by different branches of the same stepped leader during quite a short time. Based on optical images, the 2D progression speed of leader branches was estimated to be in the range (0.9–2.0) × 105 m s− 1. The distance between adjacent striking points of MGTS was from 0.2 km to 1.9 km. The percentage of flashes with multiple-ground terminations occupied about 15% (9 out of 59) of the total negative CG flashes, with a range of 11%–20% in different areas in China. The time intervals between the two adjacent peaks ranged from 4 μs to 486 μs based on the E-field change caused by the MGTS. The flashes which had multiple striking points on the ground during quite a short time may be a common phenomenon in the lightning discharge process. It might produce more serious damage to facilities on the ground and should not be neglected in the design of lightning protection.  相似文献   

2.
Using a high-speed camera system and two electric field antenna systems, we have documented the initial processes of an altitude-triggered negative lightning (ATNL). The optical records clearly show that ATNL begins with the inception and propagation of an upward positive leader (UPL) and then a simultaneous propagation of UPL and downward negative leader (DNL), known as the bidirectional leader process, follows. Based on the optical records, it is inferred that (1) the triggering height is about 371 m; (2) the two-dimensional (2D) propagation speed of the UPL in its inception phase is about 3.8–5.5 × 104 m s− 1 during its propagation from about 393 to 452 m above the ground; (3) the grey levels of the DNL are about one order of magnitude higher than that of the UPL in their inception phase; (4) a discharge phenomenon propagating along the elevated triggering wire part of the lightning channel occurs after the mini-return stroke (MRS), with a 2D propagation speed of about 1.6–2.0 × 105 m s− 1. Combined with the simultaneous electric field change records, it is further inferred that (1) the UPL incepts about 932 μs earlier than the unstable DNL and about 4.1 ms earlier than the stable DNL; (2) the unstable DNL propagates downward intermittently three times with a time interval of about 1 ms, and each propagation contains a different number of steps with an average step length of about 7 m; (3) the stable DNL incepts at the tip of the unstable one, with a 2D propagation speed of about 1.9 × 105 m s− 1, an average step length of about 3 m, and a stepping time interval varying from 6 to 31 µs with a mean value of 15 µs.  相似文献   

3.
GPS-synchronized measurements of electric (E) field changes induced by lightning flashes were recorded at six stations in the northeastern verge of the Tibetan Plateau. The height and magnitude of charge neutralized by 65 return strokes, including 16 negative cloud-to-ground (CG) flashes and 2 positive CG flashes, have been fitted with the nonlinear least-square method based on the E field changes of CG flashes observed in a typical thunderstorm with larger-than-usual lower positive charge center (LPCC). Results show that the height of the charge region neutralized by negative CG flashes ranges from 3 km to 5 km above the ground, corresponding to an ambient temperature between − 2 °C and − 15 °C. For the two positive CG flashes, the neutralized charge regions are located at a height of about 5.5 km and the ambient temperature is about − 18 °C, indicating the existence of upper positive charge in the thunderstorm.  相似文献   

4.
Study of the total lightning activity in a hailstorm   总被引:1,自引:0,他引:1  
A thunderstorm that developed over northeastern Spain on 16 June 2006 is analyzed. This severe thunderstorm produced hailstones as large as 40 mm and had a lifetime of 3 h and 30 min. Radar cross-sections show strong vertical development with cloud echo tops reaching an altitude of 13 km. The specific characteristics of the lightning activity of this storm were: (i) a large amount (81%) of negative cloud-to-ground (−CG) flashes with very low peak currents (< 10 kA in absolute value), (ii) a very large proportion of intra-cloud (IC) flashes with an IC/CG ratio reaching about 400, (iii) a large number of “short” IC flashes (with only 1-VHF source according to SAFIR detection), (iv) a large increase of the −CG flash rate and of the CG proportion near the end of the storm. The rate of −CG flashes with a low peak current were observed to evolve similarly to the rates of IC flashes. Most of them have been assumed to be IC flashes misclassified by the Spanish Lightning Detection Network (SLDN). They have been filtered as it is usually done for misclassified +CG flashes. After this filtering, CG flash rates remained very low (< 1 min− 1) with +CG flashes sometimes dominant. All the particular lightning activity characteristics similar to those observed in the Severe Thunderstorm Electrification and Precipitation Study (STEPS) campaigns support the hypothesis that this thunderstorm could have had an inverted-polarity or complex charge structure. The maximum IC flash rate (67 min− 1) peaked 24 min before the presence of reflectivity higher than 60 dBZ. The IC activity abruptly decreased during the period when reflectivity was dramatically increasing. The time of maximum reflectivity observed by radar was consistent with the times of reported hail at the ground.  相似文献   

5.
Intracloud (IC) and cloud-to-ground (CG) lightning flashes produce transient changes in the electric field (E) above a thundercloud which drive transient currents in the global electric circuit (GEC). Using in-cloud and above-cloud E data from balloons, ground-based E data, and Lightning Mapping Array data, the above-cloud charge transfers due to lightning transients are estimated for five IC and five CG flashes from four thunderstorms that occurred above the mountains in New Mexico, USA, in 1999. For the five CG flashes (which transferred − 4 to − 13 C to the ground), the transient currents moved + 1 to + 5 C of charge upward from cloudtop toward the ionosphere, with an average transient charge transfer of about 35% of the charge transferred to ground. For the five IC flashes (which neutralized 6 to 21 C inside the cloud), the transient currents moved − 0.7 to − 3 C upward, with an average transient charge transfer of about 12% of the lightning charge. Estimates for three thunderstorms indicate that the transient currents made only a small GEC contribution compared to the quasi-stationary Wilson currents because of the offsetting effects of IC and CG flashes in these storms. However, storms with extreme characteristics, such as high flash rates or predominance of one flash type, may make a significant GEC contribution via lightning transients.  相似文献   

6.
一次多回击负地闪放电过程的甚高频辐射和传输特征分析   总被引:1,自引:0,他引:1  
利用短基线时间差甚高频(VHF)辐射源定位系统对一次多回击负地闪放电过程进行详细研究发现, 负地闪的预击穿、梯级先导、直窜先导及回击后云内放电过程伴随有较强烈的VHF辐射。结合同步观测的闪电快、慢电场变化资料, 分析VHF辐射源时空发展特征发现, 预击穿阶段辐射源在云中的放电通道为双向发展, 平均速度均在104 m s-1量级, 预击穿下行分支直接转化为梯级先导, 并产生多个分支通道同时向地面发展, 先导平均速度在105 m s-1量级。继后回击之前先导过程均产生多个分支通道, 直窜先导平均速度在105~106 m s-1量级, 新开辟的梯级先导速度在105 m s-1量级。闪击间及地闪后期云内放电活动较为复杂, 主要表现为辐射源从闪电起始区域发展, 进一步延伸云内闪电通道。地闪后期多次负极性K变化过程(Kitagawa and Kobayashi, 1958)主要表现为负极性流光沿之前的正极性电离通道快速发展, 平均速度在106 m s-1量级。  相似文献   

7.
Using 2 high-speed cameras, we have recorded 14 negative cloud-to-ground (CG) lightning flashes, half of which are natural and the others are artificially triggered. The two-dimensional (2D) propagation speed of different type leaders and the luminosity of lightning channel are analyzed in detail. Bidirectional leader processes are observed during the initial processes of two altitude triggered negative lightning (ATNL)flashes. The analysis shows: the propagation speed of the upward positive leader (UPL) before the initiation of the downward negative leader (DNL) is at the order of 104-105 m s-1; the UPL can be intensified by the initiation and development of the DNL in the way that the luminosity is enhanced and the speed is sped up; after initiation, the DNL in one ATNL flash propagates downward three times intermittently with interval of about 1 ms, while that in the other ATNL flash propagates downward continuously with a speed at the order of 105 m s-1. In the five classical triggered negative lightning (CTNL) flashes, the propagation speeds of the UPLs vary between 0.35×105 and 7.71×105 m s-1, and the variations of their luminosities and speeds are quite complex during the development processes. Among the four observed natural negative lightning flashes occurred on the land, three have only one return stoke (RS) each and all of their DNLs have many branches with an average speed at the order of 105 m s-1; while the another one has 13 RSs.In the CG flash with 13 RSs, the DNL before the first RS has no obvious branch below 1.4 km above the ground, and its speed ranges from 2.2×105 to 2.3×105 m s-1 between the heights of 0.7 and 1.4 km and exceeds 3.9×106 m s-1 below 0.7 km; preceding the 4th RS, an attempted leader is observed with a speed ranging from 1.1×105 to 1.1×106 m s-1 between 0.8 and 1.5 km. As for the three observed natural negative lightning flashes occurred on the sea, each has only one RS, and each DNL preceding the RS has a few branches, two of which have an average propagation speed at the order of 105 m s-1, and the other of 106m s-1, respectively. All the DNLs contained in the observed natural negative lightning flashes, except the attempted leader, propagate with gradually increasing luminosity and increasing speed in whole.  相似文献   

8.
广州高建筑物雷电观测站光电同步观测系统于2017年6月16日记录到一次峰值电流达+141 kA的单回击正地闪触发两个并发上行闪电过程。利用高速摄像、普通摄像和电场变化数据分析了触发型上行闪电的始发特征和机理。结果表明:正地闪回击后约0.8 ms内,在距正地闪接地点约3.9 km的广州塔(高600 m)和4.1 km的东塔(高530 m)分别有上行闪电始发。正地闪回击过程中和大量正电荷以及之后可能有云内负先导朝高塔方向快速伸展造成塔顶局部区域的电场发生突变是两个上行闪电激发的原因。两个上行闪电在353 ms内发生7次回击,其中6次在广州塔上,仅1次在东塔上,且广州塔回击峰值电流平均值(-21.4 kA)约为东塔回击峰值电流(-7.3 kA)的3倍,表明广州塔上行闪电通道可能比东塔上行闪电通道伸展至分布范围更广、电荷量(或电荷密度)更大的负电荷区。两个上行闪电先导的二维速率变化范围为9.4×104~1.8×106 m·s-1,平均值为6.9×105 m·s-1。  相似文献   

9.
The study of fog dynamics in the island of Tenerife began in 1993 at six sites. The analysis of the relationship between fog and several meteorological parameters was conducted at the site located at Anaga. Anaga is located at the summit of a mountain range, at an altitude of 842 m and 3.5 km away from the north-western coastline of the island. The study uses hourly data of the three summer months (June, July and August) that were collected over a period of nine years — from 1996 to 2005. The mean summer (June–August) rainfall was found to be 21.2 mm whilst the total volume of fog water collected was 879.9 l m− 2; the daily average fog water collection was 9.5 l m− 2 day− 1, and the hourly average about 0.4 l m− 2 h− 1. Although these amounts were recorded with wind speeds of between 8 and 12 m s− 1, the correlation between water collected and wind speed is not statistically significant. In spite of this, the volume of fog water collected and wind speed showed a very distinct daily behavioural pattern, their frequency and speed reaching their minimum at 12 a.m. and their maximum from 7 p.m. to 8 a.m. GMT. The importance of this research is that it shows that the fog in the Canary Islands occurs more frequently and makes a more significant contribution to the growth of vegetation in the summer (the dry season) than in the winter, when fog accompanies rainfall.  相似文献   

10.
During the summers of 2003 to 2006 sprites were observed over thunderstorms in France by cameras on mountain tops in Southern France. The observations were part of a larger coordinated effort, the EuroSprite campaigns, with data collected simultaneously from other sources including the French radar network for precipitation structure, Meteosat with images of cloud top temperature and the Météorage network for detection of cloud-to-ground (CG) flash activity. In this paper two storms are analyzed, each producing 27 sprite events. Both storms were identified as Mesoscale Convective Systems (MCS) with a trailing stratiform configuration (ST) and reaching a maximum cloud area of ~ 120,000 km2. Most of the sprites were produced while the stratiform area was clearly developed and during periods of substantial increase of rainfall in regions with radar reflectivity between 30 and 40 dBZ. The sprite-producing periods followed a maximum in the CG lightning activity and were characterized by a low CG flash rate with a high proportion of + CG flashes, typically around 50%. All sprites were associated with + CGs except one which was observed after a − CG as detected by the Météorage network. This − CG was estimated to have − 800 C km charge moment change. The peak current of sprite-producing + CG (SP + CG) flashes was twice the average value of + CGs and close to 60 kA with little variation between the periods of sprite activity. The SP + CG flashes were further characterized by short time intervals before a subsequent CG flash (median value < 0.5 s) and with clusters of several CG flashes which suggest that SP + CG flashes often are part of multi-CG flash processes. One case of a lightning process associated with a sprite consisted of 7 CG flashes.  相似文献   

11.
The hydrodynamic equations governing the water-level response of a lake to wind stress are inverted to determine wind stress from water-level fluctuations. In order to obtain a unique solution, the wind-stress field is represented in terms of a finite number of spatially dependent basis functions with time-dependent coefficients. The discretized version of the inverse equation is solved by a least-squares procedure to obtain the coefficients, and thereby the stress. The method is tested for several ideal cases with Lake Erie topography. Real water-level data is then used to determine hourly values of vector wind stress over Lake Erie for the period 5 May–31 October, 1979. Results are compared with measurements of wind speed and direction from buoys deployed in the lake. Calculated stress direction agrees with observed wind direction for wind speeds > 7.5 m s−1. Under neutral conditions, calculated drag coefficients increase with the wind speed from 1.53 × 10−3 for 7.5−10 m s−1 winds to 2.04 × 10−3 for 15−17.5 m s−1 winds. Drag coefficients are lower for stable conditions and higher for unstable conditions.  相似文献   

12.
The characteristics of cloud-to-ground (CG) lightning for ten hailstorms in Shandong Province of China were analyzed statistically. It is found that the hailstorms in this study present dominant positive CG flashes during periods of falling hail. One specific hailstorm on 16 June 2006 was studied in detail using the data from a CG lightning location network, Doppler radar and cloud images. Comparison between the brightness temperature of cloud-top and CG flash locations indicated that most flashes occurred in the region with temperatures lower than − 40 °C, while dense positive CG flashes occurred in the range between − 40 °C and − 50 °C. Negative CG flashes occurred mostly in the relative weak radar echo region, and positive CG flashes were distributed in the strong echo region especially with a large gradient of echo intensity. CG flashes tended to occur in the cloud region with reflectivity between 25 dBZ and 35 dBZ. Comparison between the wind field retrieved from Doppler radar and the location of CG flashes indicated that the flashes were located in the convergent region at lower to middle levels.  相似文献   

13.
In July 2005, a field campaign was conducted in the Central Great Plains to obtain 60-field/s video imagery of lightning in correlation with reports from the U.S. National Lightning Detection Network (NLDN) and broadband electric field waveforms from the Los Alamos Sferic Array (LASA). A total of 342 GPS time-stamped cloud-to-ground (CG) flashes were recorded in 17 different sessions, and 311 (91%) of these were correlated with reports from the NLDN. Only 6 of the 17 recording sessions were dominated by flashes that lowered negative charge to ground, and 11 were dominated by positive CG flashes. A total of 103 flashes recorded on video were correlated with at least one NLDN report of negative CG strokes, 204 video flashes were correlated with one or two positive stroke reports, and 4 had bipolar reports. In this paper, we will give distributions of the estimated peak current, Ip, as reported by the NLDN, of negative and positive first strokes that were recorded on video, the multiplicity of strokes that were recorded on video, and the number of ground contacts per flash that were resolved on video. 41 (40%) of the negative flashes produced just a single-stroke on video, and 62 (60%) showed two or more strokes. The observed multiplicity of negative flashes averaged 2.83, which becomes about 3.14 after correcting for the finite time-resolution of the video camera. 195 (96%) of the positive flashes produced just a single-stroke on video, and 9 (4%) showed two strokes; therefore, the observed multiplicity of positive flashes averaged 1.04. Five out of 9 (56%) of the positive subsequent strokes re-illuminated a previous channel, and 4 out of 9 (44%) created a new ground contact. Simultaneous video, LASA, and NLDN measurements also allowed us to examine the classification of NLDN reports during 3 single-cell storms (one negative and two positive). Based on the LASA waveforms, a total of 204 out of 376 (54%) NLDN reports of CG strokes were determined to be for cloud pulses. The misclassified negative reports had |Ip| values ranging from 3.8 kA to 29.7 kA, but only 58 (24%) of these had |Ip| > 10 kA, and only one misclassified positive report had Ip > 20 kA. Radar analyses showed that most of the negative and positive CG strokes that were recorded on video were produced within or near the convective cores of storms. The radar imagery also showed that single-cell storms tended to produce one polarity of CG flashes at a time, and that such storms could switch rapidly from negative to positive CG flashes when the reflectivity was near maximum. Multiple-cell storms produced both negative and positive flashes over a broad region, but each polarity tended to cluster near regions of high-reflectivity.  相似文献   

14.
一次多回击自然闪电的高速摄像观测   总被引:5,自引:3,他引:2       下载免费PDF全文
2006年8月1日在广东省从化市利用成像率为5000幅/s的高速摄像系统观测得到了一次包含有13个回击过程的自然负地闪, 其梯级先导的传播速度为106 m/s的量级; 一次企图先导的传播速度随高度的降低而减小; 一次直窜先导的传播速度随高度的降低而增加。有3次继后回击相对积分亮度的峰值大于首次回击相对积分亮度的峰值。研究发现:此次自然闪电的继后回击及紧跟其后的连续电流过程的发光总量与该次继后回击之前闪电通道的截止时间有关, 较大的发光总量对应于较长的截止时间, 较小的发光总量对应于较短的截止时间, 但两者没有固定的比例关系。  相似文献   

15.
Black carbon relationships with emissions and meteorology in Xi'an, China   总被引:4,自引:0,他引:4  
Aerosol black carbon (BC) was measured every 5 min at Xi'an, China from September 2003 to August 2005. Daily BC concentrations ranged from 2 to 65 μg m− 3, averaging 14.7 ± 9.5 μg m− 3 and displayed clear summer minima and winter maxima. BC typically peaked between 0800 and 1000 LST and again between 2000 and 2200 LST, corresponding with morning and evening traffic combined with nighttime residential cooking and heating. The nocturnal peak was especially evident in winter, when more domestic heating is used and pollutant-trapping surface-inversions form earlier than in summer. BC frequency distributions the most commonly occurring concentrations occurred between 5 and 10 μg m− 3 in all four seasons. BC ranged from 1.6% and 15.6%, and averaged 8.3% of PM2.5. A clear inverse relationship between BC and wind speed (WS) was found when WS was below 2.5 to 3.0 m s− 1, implying a local origin for BC. Mixed layer depths (MLDs) were shallower during BC episodes compared to cleaner conditions.  相似文献   

16.
Coastal nucleation events and behavior of cluster ions were characterized through the measurements of air ion mobility distributions at the Mace Head research station on the west coast of Ireland in 2006. We measured concentrations of cluster ions and charged aerosol particles in the size range of 0.34–40 nm. These measurements allow us to characterize freshly nucleated charged particles with diameters smaller than 3 nm. The analysis shows that bursts of intermediate ions (1.6–7 nm) are a frequent phenomenon in the marine coastal environment. Intermediate ion concentrations were generally close to zero, but during some nucleation episodes the concentrations increased to several hundreds per cm3. Nucleation events occurred during most of the measurement days. We classified all days into one of seven classes according to the occurrence and type of new particle formation. Nucleation events were observed during 207 days in 2006, most prominently in the spring and summer months. Rain-induced events, in turn, were observed during 132 days. Particle formation and growth events mostly coincided with the presence of low tide. Also small cluster ions (0.34–1.6 nm) were characterized. Average concentrations of small ions were 440 cm− 3 for the negative ions and 423 cm− 3 for the positive ions. Average mean mobilities of small ions were 1.86 cm2V− 1s− 1 and 1.49 cm2V− 1s− 1 for the negative and positive polarities, respectively. Concentrations of small ions were observed to be strongly dependent on the variations of meteorological parameters including wind speed and direction.  相似文献   

17.
2006—2011年广州人工触发闪电   总被引:1,自引:1,他引:0       下载免费PDF全文
2006—2011年夏季在广州野外雷电试验基地开展了广东综合闪电观测试验 (GCOELD)。试验期间,针对人工触发闪电进行了近距离声、光、电、磁特征等综合测量,对自动气象站电源线和信号线上产生的感应电压特征进行了观测和分析,并对广东省地闪定位网的探测效率和定位精度与人工触发闪电进行了比对和校验。试验结果表明:人工触发闪电回击峰值电流范围为-31.93~-6.67 kA,回击电流波形的半峰宽度的范围为6.18~74.19 μs,10%—90%的上升时间范围为0.24~2.25 μs。触发闪电的上行正先导的发展速度在104~105 m/s量级;人工触发闪电的回击过程在架空电源线路 (1200 m长,2 m高) 上产生的感应过电压可达十几千伏;广东电网闪电定位系统对人工触发闪电事件的探测效率为95%,平均定位误差为759 m,闪电定位系统反演得到的电流峰值与实际测量的电流峰值平均相对偏差为16.3%。  相似文献   

18.
作为中国气象局雷电野外科学试验基地(CMA_FEBLS)的重要组成部分,广州高建筑物雷电观测站(TOLOG)始建于2009年,迄今已积累数百次高建筑物雷电资料。对于雷电连接过程,高建筑物会起到“放大镜”的作用:TOLOG的观测在国际上首次发现了连接过程中负-正先导之间“头部-侧面”连接的现象,给出了先导连接行为的两种基本形态;揭示了负先导梯级发展过程的精细化结构,给出了下行先导和上行先导的二维/三维发展特征;估算了不同高度建筑物上雷电的闪击距离。高建筑物对雷电电磁场具有“放大器”的作用,且建筑物越高增强效应越显著。高建筑物是下行和上行闪电的“汇集点”:对下行闪电的吸引作用可保护高建筑物附近的其他物体免遭雷击;正地闪的回击、延续电流和云内放电过程均可在高建筑物上触发负极性上行闪电。另外,高建筑物区域可作为闪电监测系统的“标校场”,TOLOG的观测资料在地闪定位系统探测效率和定位精度的评估方面也得到了应用。  相似文献   

19.
闪电初始阶段和尺度判别方法及其特征   总被引:5,自引:5,他引:0       下载免费PDF全文
基于LMA三维闪电定位数据,对2004年10月5日发生于美国新墨西哥州的一次超级单体过程的闪电初始及其尺度特征进行研究,提出闪电初始阶段自动判别及其特征参量提取方法,并给出参量分布特征。结果显示:闪电初始阶段上行负先导(下行负先导)的持续时间中值为13.5 ms(7.5 ms),三维位移中值为1.4 km(1.0 km),三维平均位移速度中值为9.2×104 m·s-1(1.2×105 m·s-1),上行负先导速度随时间递减,下行反之,二者与垂直方向夹角的中值分别为40°和54°。表征闪电尺度的闪电凸壳面积和闪电总长度的概率密度呈负幂函数分布,在小值方向分布更为集中。闪电水平延展距离中值为6.1 km,垂直延展距离中值为4.3 km,约83%的闪电其水平延展距离大于垂直延展距离;闪电的持续时间中值为271.0 ms。分析发现,以水平延展为主的闪电起始高度分布峰值位于8.5 km,以垂直延展为主的闪电起始高度分布峰值位于11 km。闪电初始阶段位移方向越接近水平,对应闪电垂直延展越小,说明闪电初始段的传播方向对于闪电垂直延展具有重要影响。  相似文献   

20.
The initial discharge stages of two flashes during the Shandong Artificially Triggering Lightning Experiment (SHATLE) are analyzed based on the synchronous data of the current and close electromagnetic field. For a lightning flash, named 0503, the wire was connected, not electrically, but via a 5 m length of nylon, with the lightning rod; while for another, named 0602, the wire was connected with the rod directly. Results show that the discharge processes of the initial stage (IS) in flash 0503 are quite different from that of the usual classical-triggered flash 0602 and altitude-triggered flashes. A large pulse with a current of about 720 A resulted from the breakdown of the 5 m air gap during flash 0503, and the corresponding electric field at 60 m from the lightning rod was 0.38 kV/m. The upward positive leaders (UPLs) propagated continuously from the tip of the rocket after this breakdown. The geometric mean (GM) of the UPL peak current was 23.0 A. Vaporization of the wire occurred during the initial continuous current (ICC) stage and the largest current pulse was about 400 A. Compared with triggered flash 0503, the discharge processes of IS in flash 0602 were simple, only two large pulses similar to each other occurred before dart leader/return stroke sequences. The peak current of the first pulse was 2.1 kA and its corresponding electric field and magnetic field at a distance of 60 m from the lightning rod were 0.98 kV/m and 7.03 μT, respectively. During the second pulse, the wire disintegrated. The current decreased to the background level at the moment of the wire disintegration. The current of the second pulse in triggered flash 0602 was 2.8 kA, and the corresponding electric field and magnetic field at 60 m from the lightning rod were 1.22 kV/m and 9.01 μT, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号