首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 734 毫秒
1.
In sparsely cropped farming systems in semi-arid tropics, rainfall partitioning can be complex due to various interactions between vertical and horizontal water flows, both in the atmosphere and in the soil. Despite this, quantifying the seasonal rainfall partitioning is essential, in order to identify options for increased yields. Results are presented on water flow components, based on field measurements and water balance modelling, for three years (1994–96) in a farmer's field cultivated with pearl millet [Pennisetum glaucum (L.) Br.] in the Sahel (Niger). Water balance modelling was carried out for three common infiltration categories: runoff producing surfaces, surfaces receiving inflow of runon water from upstream zones, and a reference surface with zero runoff and runon. Runoff was calculated to 25%–30% of annual rainfall (which ranged from 488 to 596 mm), from crust observations, rainfall, soil wetness data, and infiltration estimates. Inflow of runon was estimated from field observations to 8%–18% of annual rainfall. The parameters in the functions for soil surface and canopy resistances were calibrated with field measurements of soil evaporation, stomatal conductance and leaf area. The model estimates of soil water contents, which were validated against neutron probe measurements, showed a reasonable agreement with observed data, with a root mean square error (RMSE) of approximately 0.02 m3 m−3 for 0–160 cm soil depth. Estimated productive water flow as plant transpiration was low, amounting to 4%–9% of the available water for the non-fertilised crop and 7%–24% for the fertilised crop. Soil evaporation accounted for 31%–50% of the available water, and showed a low variation for the observed range of leaf area (LAI <1 m2 m−2). Deep percolation was high, amounting to 200–330 mm for the non-crusted surfaces, which exceeded soil evaporation losses, for 1994–95 with relatively high annual rainfall (517–596 mm). Even a year with lower rainfall (488 mm) and a distinct dry spell during flowering (1996), resulted in an estimated deep percolation of 160 mm for the non-fertilised crop. The crop did not benefit from the additional inflow of runon water, which was partitioned between soil water storage and deep percolation. The only exception to this was the fertilised crop in 1996, where runon somewhat compensated for the limited rainfall and the higher water demand as a result of a larger leaf area than the non-fertilised crop. The effects of rainfall erraticness, resulting in episodic droughts, explain why a crop that uses such a small proportion of the available water, in an environment with substantial deep percolation, still suffers from water scarcity. Application of small levels of phosphorus and nitrogen roughly doubled yields, from 380 to 620 kg ha−1, and plant transpiration, from 33 to 78 mm. Evapotranspirational water use efficiency (WUEET) was low, 6500–8300 m3 ton−1 grain for non-fertilised crop, which is an effect of the low on-farm yields and high non-productive water losses. The estimated seasonal rainfall partitioning indicates the possibility of quantifying vertical water flows in on-farm environments in the Sahel, despite the presence of surface overland flow.  相似文献   

2.
Two ground penetrating radar (GPR) techniques were used to estimate the shallow soil water content at the field scale. The first technique is based on the ground wave velocity measured with a bistatic impulse radar connected to 450 MHz ground-coupled antennas. The second technique is based on inverse modeling of an off-ground monostatic TEM horn antenna in the 0.8–1.6 GHz frequency range. Data were collected on a 8 by 9 m partially irrigated intensive research plot and along four 148.5 m transects. Time domain reflectometry, capacitance sensors, and volumetric soil samples were used as reference measurements. The aim of the study was to test the applicability of the ground wave method and the off-ground inverse modeling approach at the field scale for a soil with a silt loam texture. The results for the ground wave technique were difficult to interpret due to the strong attenuation of the GPR signal, which is related to the silt loam texture at the test site. The root mean square error of the ground wave technique was 0.076 m3 m−3 when compared to the TDR measurements and 0.102 m3 m−3 when compared with the volumetric soil samples. The off-ground monostatic GPR measured less within-field soil water content variability than the reference measurements, resulting in a root mean square error of 0.053 m3 m−3 when compared with the TDR measurements and an error of 0.051 m3 m−3 when compared with the volumetric soil samples. The variability between the two GPR measurements was even larger with a RSME of 0.115 m3 m−3. In summary, both GPR methods did not provide adequate spatial information on soil water content variation at the field scale. The main reason for the deviating results of the ground wave method was the poor data quality due to high silt and clay content at the test site. Additional reasons were shallow reflections and the dry upper soil layer that cannot be detected by the ground wave method. In the case of off-ground GPR, the high sensitivity to the dry surface layer is the most likely reason for the observed deviations. The off-ground GPR results might be improved by using a different antenna that allows data acquisition in a lower frequency range.  相似文献   

3.
The determination of the earthquake energy budget remains a challenging issue for Earth scientists, as understanding the partitioning of energy is a key towards the understanding the physics of earthquakes. Here we estimate the partition of the mechanical work density into heat and surface energy (energy required to create new fracture surface) during seismic slip on a location along a fault. Earthquake energy partitioning is determined from field and microstructural analyses of a fault segment decorated by pseudotachylyte (solidified friction-induced melt produced during seismic slip) exhumed from a depth of ~ 10 km—typical for earthquake hypocenters in the continental crust. Frictional heat per unit fault area estimated from the thickness of pseudotachylytes is ~ 27 MJ m− 2. Surface energy, estimated from microcrack density inside clast (i.e., cracked grains) entrapped in the pseudotachylyte and in the fault wall rock, ranges between 0.10 and 0.85 MJ m− 2. Our estimates for the studied fault segment suggest that ~ 97–99% of the energy was dissipated as heat during seismic slip. We conclude that at 10 km depth, less than 3% of the total mechanical work density is adsorbed as surface energy on the fault plane during earthquake rupture.  相似文献   

4.
Measurements of transpiration from individual trees of Eucalyptus from plantations at four different sites in Karnataka, Southern India, are presented. These show large (as much as tenfold) differences in the transpiration between premonsoon and postmonsoon periods, a reflection of the effects of soil-moisture stress in the premonsoon periods. For trees with diameters at breast height (DBH) less than 10 cm the transpiration rate of individual trees is proportional to the square of the DBH. For trees which are not experiencing soil-water stress the daily transpiration rate of individual trees, q, is well represented by the relation: q = (6.6 ± 0.3)g (m3 day−1 where g (m2) is the tree basal area. On a unit ground area basis the transpiration rate, expressed as a depth per day is given by the relation: Et = (0.66 ± 0.03)G (mm day−1 where g(m2ha−1) is the total basal area per hectare. For all the sites studied, although there is evidence for the ‘mining’ of soil water as roots penetrate deeper depths in the soil each year, there is no evidence for direct abstraction from the water table.  相似文献   

5.
In the present work, we built a mathematical model of polychlorinated biphenyl (PCB) bioaccumulation in Perna viridis, namely, a one-compartment model with a time dependent incorporation rate R (μg g−1 lipid per ppb water per day), with positive substrate cooperativity as the underlying physical mechanism. The temporal change of the PCB concentration Q (μg g−1 lipid) in the soft tissues of the mussel depends on the competition of the input rate RW and the output rate kQ, where W is the concentration of PCB in water (ppb water) and k is the elimination rate (per day). From our experimental data, k=0.181±0.017 d−1. The critical concentration in water Wc for positive substrate cooperativity was found to be 2.4 ppb. Below Wc, R is a constant. For a water concentration of 0.5 ppb Aroclor 1254, R=24.0±2.4 μg g−1 lipid ppb−1 d−1. Above Wc, positive substrate cooperativity comes into effect and R becomes a function of time and dependent on the concentration Q in a form RQ/(Q+δ). This is the case for a water concentration of 5 ppb Aroclor 1254, where γ=15.1 μg g−1 lipid ppb−1 d1 and δ≈200 μg g−1 lipid. From this model, the uptake is exponentially increasing when the PCB concentration in the mussel is small compared to 200 μg g−1 lipid, and hyperbolically increasing when the concentration is large compared to 200 μg g−1 lipid, which are consistent with the experimental data. The model is useful for understanding the true processes taking place during the bioaccumulation and for risk assessment with higher confidence. Future experimental data which challenge the present model are anticipated and in fact desirable for improvement and perfection of the model.  相似文献   

6.
PCBs, p,p′-DDT, p,p′-DDE and lindane (γ-hexachlorocyclohexane) were monitored in the lower atmosphere of Ross Island, in Antarctica for 2 yr. Geometrical means were 15.2 pg m−3 for PCBs, 2.0 pg m−3 for p,p′-DDT, 1.0 pg m−3 for p,p′-DDE and 25.8 pg m−3 for lindane. Atmospheric levels of lindane were positively correlated with temperature, and a significant difference was found between spring-summer and summer-winter concentrations. No season related differences were found for the other chlorinated hydrocarbons, possibly owing to their lower vapour pressure and the cold climate. Periods with increased atmospheric levels of PCBs and DDT compounds were recorded. Lindane, p,p′-DDE and PCBs were present in fish and zooplankton sampled close to Ross Island. Pollutant levels in the zooplankton (on an extractable fat basis) were highest during the Antarctic spring and autumn and were inversely correlated to their fat content.  相似文献   

7.
The effects of salinity, temperature, and light conditions on the reproduction and development of harpacticoid copepod, Nitocra affinis f. californica under controlled laboratory conditions were determined. Seven different salinity levels (5, 10, 15, 20, 25, 30, 35 ppt), four temperatures (20, 25, 30, 35 °C), three different light intensities (25, 56, 130 μmol m−2 s−1) and photoperiods (24 h:0 h, 1 h:23 h, 12 h:12 h LD cycle) were employed in this study. The highest (p < 0.05) overall reproduction and fastest development time were achieved by copepods reared under 30–35 ppt salinity. The optimum temperature required for the maximum reproduction was 30 °C while under 30 °C and 35 °C the copepod development time was shortest (p < 0.05) compared to other temperature levels. The overall reproduction was highest (p < 0.05) and development rate of N. affinis was shortest (p < 0.05) under lowest light intensity (25 μmol m−2 s−1). Continuous light (24 h:0 h LD) inhibited the egg production while, continuous darkness (1 h:23 h LD) and 12 h:12 h LD significantly favoured the overall reproductive activity of the female. Photoperiods 1 h:23 h and 12 h:12 h LD yielded highest total (p < 0.05) offspring female−1 coupled with highest (p < 0.05) survival percentage. This study illustrated that although N. affinis can tolerate wide range of environmental conditions, prolonged exposure to subnormal environments affect its reproduction and development. This study showed that this species can be mass cultured for commercial purposes and has a potential to be used for toxicity studies due to its high reproductive performance fast development and a wide range of tolerance to environmental conditions.  相似文献   

8.
In 1995–1998, Han 11 km terrestrial surge of Kuannersuit Glacier, an outlet glacier of the largest ice cap on Disko Island, West Greenland, affected the catchment dramatically. In order to estimate solute fluxes and provenances, bulk meltwaters were sampled at the main subglacial outlet during the initial part of the quiescent phase. The hydrochemistry is significantly influenced by a subglacial basaltic weathering regime with absence of carbonate minerals. The results show that marine and aerosol derived solutes have minimal contribution to the total ion content, whereas sequestration of atmospheric CO2 associated with carbonation of Ca-rich feldspar and reactive volcanic glass is more dominant than previously reported from glacierized catchments. Application of a sampling strategy dividing water samples into four groups to determine the content of dissolved HCO3 and CO32− shows that the cationic equivalent weathering rate range is 683–860 Σmeq+ m−2 a−1 and solute flux ranges between 76 and 98 t km−2 a−1. The crustal denudation rate is estimated to 26 t km−2 a−1, and the transient CO2 drawdown amounts to 8500–13700 kg C km−2 a−1.  相似文献   

9.
A study of the interaction between groundwater and surface water was undertaken within a small agricultural watershed in southern Ontario, Canada. Groundwater contributions to streamflow were measured along a section of stream during baseflow conditions and during rainfall events. Four techniques were used to estimate the contribution of groundwater to the stream along a 450 m reach (three during baseflow and one during stormflow conditions). Under baseflow conditions, streamflow measurements using the velocity–area technique indicated that the net groundwater flux to the stream during the summer months was 10 ml s−1 m−1. Hydrometric measurements (i.e. hydraulic gradient and hydraulic conductivity) taken using mini-piezometers installed in the sediments beneath the stream resulted in net groundwater flux estimates that were four to five times lower. Seepage meters failed to provide any measurements of water flux into or out of the stream. Therefore, based on these results, the velocity–area technique gives the best estimate of groundwater discharge. Hydrograph separations were conducted using isotopic ratios and electrical conductivity on two large rainfall events with different antecedent moisture conditions in the catchment. Both events showed that pre-event water (generally considered groundwater) dominated streamflow and tile drain flow with 64%–80% of the total discharge contributed by pre-event water. High water table conditions within the catchment resulted in greater stream discharge and a greater contribution of event water in the streamflow than that observed under low water table conditions for similar intensity storm events. The results also showed that differences in riparian zone width, vegetation and surface saturation conditions between the upper and lower catchment can influence the relative magnitude of streamflow response from the two catchment areas.  相似文献   

10.
This paper presents an ecological–economic model for a lake and its watershed systems. We describe the linkage between the watershed system and the lake aquatic ecosystem and the modeling process. The lake–watershed system was divided into six subsystems: social system, economic system, terrestrial ecosystem, lake water system, pollutant system, and lake aquatic ecosystem. The model equations were constructed based on five main assumptions. The Lake Qionghai watershed in southwestern China, which is undergoing rapid eutrophication, was used as a case study. The targeted goals for total phosphorus (TP) and chlorophyll a (Chl a) concentrations in the lake in 2015 are 0.025 and 10.0 mg m−3, respectively. We present two scenarios from 2004 to 2015 based on the ecological–economic model. In both scenarios, the TP and Chl a concentrations in the lake are predicted to increase under the effects of watershed pressures and the targeted goals cannot be met. The application of techniques to reduce pollutants loading and the corresponding pollutants reductions are reflected again in the constructed model. The model predicts that TP and Chl a concentrations will decrease to 0.024 and 7.71 mg m−3, respectively, which meet the targeted thresholds. The model results provide directions for local government management of watersheds and lake aquatic ecosystem restoration.  相似文献   

11.
Abstract

Rainfall simulators have often been used to mimic natural rainfall for studies of various land-surface and water interaction processes. The characteristics of the simulated rainfall are the main indicators used to judge the performance of the rainfall simulators. The aim of this study is to investigate the potential of piezoelectric transducers for measuring and evaluating a dripper-type simulated rainfall drop-size distribution (DSD) and kinetic energy (KE). The directly measured KE was significantly correlated with the estimated KE using the drop-size distribution and empirical rain drop fall velocity relationships. This result emphasizes the potential use of the piezoelectric sensor to directly measure and evaluate rainfall kinetic energy. Also, the relationship between rainfall intensity and KE showed good patterns of agreement between simulated rainfall and natural rainfall.

Citation Abd Elbasit, M. A. M., Yasuda, H. & Salmi, A. (2011) Application of piezoelectric transducers in simulated rainfall erosivity assessment. Hydrol. Sci. J. 56(1), 187–194.  相似文献   

12.
Water-budget components and the vertical conductance were determined for Lowry (Sand Hill) Lake in north-central Florida, USA. In this type of lake, which interacts with both the surface-water and groundwater systems, the inflow components are precipitation, surface-water inflow, groundwater inflow, and direct runoff (i.e. overland flow), and the outflow components are evaporation, groundwater outflow, and surface-water outflow. In a lake and groundwater system that is typical of many karst lakes in Florida, a large part of the groundwater outflow occurs by means of vertical leakage through an underlying confining unit to a deeper, highly transmissive aquifer called the upper Floridan aquifer. The water-budget component that represents vertical leakage to the upper Floridan aquifer was calculated as a residual using the water-budget equation. For the 13 month period from August 1994 to August 1995, relative to the surface area of the lake, rainfall at Lowry Lake was 1.55 m yr−1, surficial aquifer inflow was 0.79 m yr−1, surface-water inflow was 1.92 m yr−1, and direct runoff was 0.01 m yr−1. Lake evaporation was 1.11 m yr−1, and surface-water outflow was 1.61 m yr−1. The lake stage increased 0.07 m yr−1, and the vertical leakage to the upper Floridan aquifer was 1.48 m yr−1. Surficial aquifer outflow from the lake was negligible. At Lowry Lake, vertical leakage is a major component of the water budget, comprising about 35% of the outflow during the study period. The vertical conductance (KV/b), a coefficient that represents the average of the vertical conductances of the hydrogeologic units between the bottom of a lake and the top of the upper Floridan aquifer, was determined to be 2.51 × 10−4 day−1 for Lowry Lake.  相似文献   

13.
Four distinct approaches, that vary markedly in the spatial and temporal resolution of their measurement and process-level outputs, are used to investigate the daily and seasonal water vapour exchange in a 70-year-old Belgian Scots pine forest. Transpiration, canopy interception, soil evaporation and evapotranspiration are simulated, using a stand-level process model (SECRETS) and a soil water balance model (WAVE). Simulated transpiration was compared with up-scaled sap flow measurements and simulated evapotranspiration to eddy covariance measurements.

Reasonable agreement in the temporal trends and in the annual water balance between the two models was observed, however daily and weekly predictions often diverged. Most notably, WAVE estimated very low, to no transpiration during late autumn, winter and early spring when incident radiation fell below 50 W m−2 while SECRETS simulated low (0.1–0.4 mm day−1) fluxes during the same period. Both models exhibited similar daily trends in simulated transpiration when compared with sap flow estimates, although simulations from SECRETS were more closely aligned. In contrast, WAVE over-estimated transpiration during periods of no rainfall and under-estimated transpiration during rainfall. Yearly, total evapotranspiration simulated by the models were similar, i.e. 658 mm (1997) and 632 mm (1998) for WAVE and 567 mm (1997) and 619 mm (1998) for SECRETS.

Maximum weekly-average evapotranspiration for WAVE exceeded 5 mm day−1, while SECRETS never exceeded 4 mm day−1. Both models, in general, simulated higher evapotranspiration than that measured with the eddy covariance technique. An impact of the soil water content in the direct relationship between the models and the eddy covariance measurements was found.

The results suggest that: (1) different model formulations can reproduce similar results depending on the scale at which outputs are resolved, (2) SECRETS estimates of transpiration were well correlated with the empirical measurements, and (3) neither model fitted favourably to the eddy covariance technique.  相似文献   


14.
The activity ratios of Pu and radiocesium isotopes have been used to delineate the major sources (such as global and close-in (debris) fallout, nuclear fuel reprocessing and fabrication plant effluents) in the environment. We have measured 238Pu, 239,240Pu, 137Cs, and excess 210Pb concentrations in 107 surficial sediments as well as in 5 sediment cores collected in the summer months of 1993 and 1994 from the Ob and Yenisey Rivers (Russia) and the Kara sea. A comparison of the sediment core inventories of 239,240Pu and 137Cs, along with the 238Pu/239,240Pu activity ratios, with those expected from global fallout allows us to estimate the relative amounts, if any, of reactor-derived 238Pu and 239,240Pu from the dumped reactor sites in the study area.

In surficial sediment samples collected in 1993 and 1994, the 239,240Pu concentrations varied between 4.2 and 856 mBq kg−1, with a mean of 239 mBq kg−1. In samples with a measurable 238Pu, the 238Pu/239,240Pu activity ratios varied between 0.010 and 0.069, with an average value of 0.035 ± 0.014. This range can be compared to the average 238Pu/239,240Pu activity ratio of 0.030 for the year 1993 from nuclear weapons testing and SNAP fallout obtained from soil studies, indicating very little (≤ 5%) additional sources of 238Pu to the sediments in the study area. The inventories of Pu in the 5 sediment cores from the study area varied between 2.67 ± 0.67 and 24.5 ± 2.2 Bq m−2 with a mean value of 8.83 Bq m−2. The 137Cs concentrations in the upper 3 cm of the sediments varied between below detection limit to 71.4 Bq kg−1, with a mean of 14.9 Bq kg−1. The 137Cs inventories in the 5 sediment cores varied between 156.7 ± 28.3 and 1600 ± 153.3 Bq m−2, with a mean value of 583.3 Bq m−2. The mean ratio of inventories of Pu to that of 137Cs, 0.015, is comparable to the values in other places in the Arctic region. There is a significant correlation between total organic carbon and concentrations of 137Cs, 239,240Pu and 210Pb, suggesting that organic matter-enriched fine particles are a likely carrier phase for these nuclides. The ratio of 137Cs/239,240Pu also suggests that most of these nuclides are derived from global fallout.  相似文献   


15.
Welded tuffs in the Bogopol and Sijanov groups were sampled at 27 sites from 12 caldera formations in the Sikhote Alin mountain range around Kavalerovo (44.3°N, 135.0°E) for chronological and paleomagnetic studies. KAr age dates show that the welded tuffs erupted between 66 Ma and 46 Ma. All sites yield reliable paleomagnetic directions, with unblocking temperatures higher than 560°C. The high-temperature component at 12 sites and the medium-temperature component at 3 sites in the Bogopol Group show reversed polarity (D = 193.7°, I = −57.6°,95 = 8.1°). The high-temperature component at 11 sites in the Sijanov Group showed both reversed and normal polarities and its mean direction reveals no detectable deflection from north (D = −2.9°, I = 59.6°,95 = 11.2°). The combined paleomagnetic direction of the two groups yields a paleomagnetic pole of 250.5°E, 84.1°N (A95 = 8.8°), which falls near Cretaceous paleomagnetic poles from Outer Mongolia, Inner Mongolia, the North China Block and the South China Block. The Sikhote Alin area appears not to have been subjected to detectable motion with respect to East Asia since about 50 Ma. This implies that the Sikhote Alin area behaved as an integral part of East Asia during the opening of the Japan Sea at about 15 Ma. However, significant separation between the paleomagnetic poles of East Asia and Europe during the Jurassic-Paleogene implies a major relative movement between these two blocks since the Paleogene.  相似文献   

16.
对四川盆地东北部巴中地区和西部雅安地区早白垩世红层分别采集9块手标本,进行了详细的古地磁学研究.系统退磁获得两地的特征剩磁,其中巴中地区平均方向为,倾斜校正之前:D_g/I_g=25.3°/19.0°,k=18.6,α_(95)=8.8°;倾斜校正之后:D_s/I_s=25.8°/18.9°,k=24.3,α_(95)=7.6°.雅安地区平均方向为,倾斜校正之前:D_g/I_g=24.5°/45.0°,k=15.7,α_(95)=9.0°;倾斜校正之后:D_s/I_s=356.7°/35.6°,k=28.5,α_(95)=6.6°.磁化率各向异性实验结果显示两地均未受到显著的构造应力影响.等温剩磁各向异性(AIR)实验结果,巴中地区IRMz/IRMLx平均值为0.8194,表明18%的压实率;雅安地区IRMz/IRMx平均值为0.8909,表明11%的压实率,计算得到巴中和雅安地区校正后的磁倾角分别为22.7°和38.8°.根据等温剩磁各向异性(AIR)实验和Tauxe and Kent(2004)提出的EI校正法得到的结果表明,四川盆地早白垩世陆相碎屑岩层中存在沉积压实作用造成的磁倾角偏低现象,而且川东北巴中地区的偏低程度强于川西雅安地区.  相似文献   

17.
ABSTRACT

Optical disdrometers can be used to estimate rainfall erosivity; however, the relative accuracy of different disdrometers is unclear. This study compared three types of optical laser-based disdrometers to quantify differences in measured rainfall characteristics and to develop correction factors for kinetic energy (KE). Two identical PWS100 (Campbell Scientific), one Laser Precipitation Monitor (Thies Clima) and a first-generation Parsivel (OTT) were collocated with a weighing rain gauge (OTT Pluvio2) at a site in Austria. All disdrometers underestimated total rainfall compared to the rain gauge with relative biases from 2% to 29%. Differences in drop size distribution and velocity resulted in different KE estimates. By applying a linear regression to the KE–intensity relationship of each disdrometer, a correction factor for KE between the disdrometers was developed. This factor ranged from 1.15 to 1.36 and allowed comparison of KE between different disdrometer types despite differences in measured drop size and velocity.  相似文献   

18.
New measurements of high field magnetisation (Is), remanence (Is), and coercive force (Hc) are presented between 4 and 300 K for x = 0.4, 0.5, 0.6 and 0.8 (Fe3−xTixO4). For x = 0.4 a pronounced minimum is found at T100 K and for X = 0.5 and 0.6 broad minima occur around T200 K, apparently coinciding with the temperature for K10. The magnetic properties below T60 K ar complex and were found to be significantly changed by cooling in the presence of a high magnetic field. With no applied field during cooling, a distinct decrease in Is is observed for T60 K, at which temperature there is a peak in the value of Irs. The effe cooling is to eliminate the sharp decrease in Is, reduce Hc and to increase Irs below 60 K to a value the peak value, giving essentially a square hysteresis loop. The results are interpreted in terms of a form of crystallographic phase transition coupled to the magnetisation direction, possibly by the magnetostriction. Square hysteresis loops in ferrites have been explained by the presence of Jahn-Teller ions and, in the present case, the low temperature of the observed effect may be a consequence of the weak Fe2+ Jahn-Teller ion coupled to other effects such as spin-lattice coupling.

Details of this work can be found in Schmidbauer, E. and Readman, P.W., 1982. Low temperature magnetic properties of Ti-rich Fe---Ti spinels. J. Magn. Magn. Mat., 27: 114–118. A paper reporting further work on Fe2.4Ti0.6O0.4 is in preparation.  相似文献   


19.
为了研究高宽比对配筋砌块砌体剪力墙耗能能力的影响,确定墙体的耗能参数。利用6片高宽比H/h为1.57、1.14和0.71的足尺全灌芯配筋砌块砌体剪力墙拟静力试验,通过计算墙体的耗散能(累积和单圈)、等效粘滞阻尼比ζeq、能量耗散系数ψ和功比指数Iw四个参数,来分析发生剪切型破坏模式墙体的耗能能力。研究结果表明:H/h对墙体的耗能能力影响较大,随着墙体变形的增大,H/h越小墙体的耗散能增长越迅速,墙体的延性越差;当H/h=1.14时,能量耗散系数ψ较低,等效粘滞阻尼比ζeq较小,约为7%~10%,墙体的耗能能力较差;当H/h=0.71时,ψ较高,ζeq较大,约为14%~15%,墙体的耗能能力较好;随着位移的增大,功比指数Iw逐渐增大,当位移较小时Iw几乎呈线性增长,当位移较大时Iw呈非线性增长,H/h=1.14墙体的Iw增长相对缓慢。可见:对于发生剪切型破坏模式的配筋砌块砌体剪力墙,H/h接近1时耗能能力较差,在工程中尽量避免采用。  相似文献   

20.
Data on drop size distribution and kinetic energy load of rainstorms are basic for rainfall erosivity indices. A simple and relatively inexpensive instrument was used to asses the instantaneous intensity and kinetic energy load of rainstorms in Hong Kong. Both the drop size and the instantaneous kinetic energy load of rainfall in Hong Kong are greater than in temperate and subtropical climates. The high kinetic energy results from the large size and greater number of raindrops falling per unit time. A high correlation between the kinetic energy of rainfall and the amount of rainfall allows for a convenient estimate of the energy load of storms from the amount of rainfall. Of more significance to the erosion process is the determination that about 74% of the total annual rainfall is erosive, containing about three‐quarters of the total annual energy load of the rains. The variability of rainfall parameters within a rainfall and from storm to storm is shown. The energy–intensity relationship, seasonal and annual distributions of rainfall erosivity are presented. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号