首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Reference materials (RMs) with well-characterised composition are necessary for reliable quantification and quality control of isotopic analyses of geological samples. For in situ Rb-Sr analysis of silicate minerals via laser ablation inductively coupled plasma tandem mass spectrometry (LA-ICP-MS/MS) with a collision/reaction cell, there is a general lack of mineral-specific and matrix-matched RMs, which limits wider application of this new laser-based dating technique to certain minerals. In this work, pressed nano-powder pellets (NP) of four RMs, GL-O (glauconite), Mica-Mg (phlogopite), Mica-Fe (biotite) and FK-N (K-feldspar), were analysed and tested for in situ Rb-Sr dating, complemented by isotope dilution (ID) MC-ICP-MS Rb-Sr analyses of GL-O and Mica-Mg. In addition, we attempted to develop alternative flux-free and fused ‘mineral glasses’ from the above RMs for in situ Rb-Sr dating applications. Overall, the results of this study showed that among the above RMs only two NP (Mica-Mg-NP and GL-O-NP) were suitable and robust for in situ dating applications. These two nano-powder reference materials, Mica-Mg-NP and GL-O-NP, were thus used as primary RMs to normalise and determine Rb-Sr ages for three natural minerals: MDC phlogopite and GL-O glauconite grains, and also Mica-Fe-NP (biotite). Our in situ analyses of the above RMs yielded Rb-Sr ages that are in good agreement (within 8%) of published ages, which suggests that both Mica-Mg-NP and GL-O-NP are suitable RMs for in situ Rb-Sr dating of phlogopite, glauconite and biotite. However, using secondary RMs is recommended to monitor the quality of the obtained ages.  相似文献   

2.
We have measured 87Sr/86Sr and 143 Nd/144 Nd isotope ratios in different batches and aliquots of the new US Geological Survey (USGS) reference materials (RMs) BCR-2, BHVO-2, AGV-2 and GSP-2 and the original USGS RMs BCR-1, BHVO-1, AGV-1 and GSP-1 by thermal ionisation mass spectrometry. In addition, we also analysed the eight Max-Planck-Institut-Dingwell (MPI-DING) reference glasses. Nearly all isotope ratios obtained in the different aliquots and batches agree within uncertainty limits indicating excellent homogeneity of the USGS powders and the MPI-DING glasses. With the exception of GSP-2, the new USGS RMs are also indistinguishable from the ratios found in the original USGS RMs (87Sr/86Sr: 0.704960, 0.704958 (BCR-1, -2), 0.703436, 0.703435 (BHVO-1, -2), 0.703931, 0.703931 (AGV-1, -2); 143 Nd/144 Nd: 0.512629, 0.512633 (BCR-1, -2), 0.512957, 0.512957 (BHVO-1, -2); 0.512758, 0.512755 (AGV-1, -2)). This means that for normalisation purposes in Sr and Nd isotope geochemistry BCR-2, BHVO-2 and AGV-2 can well replace BCR-1, BHVO-1 and AGV-1 respectively.  相似文献   

3.
Measurement of Ba isotope ratios of widely available reference materials is required for interlaboratory comparison of data. Here, we present new Ba isotope data for thirty‐four geological reference materials, including silicates, carbonates, river/marine sediments and soils. These reference materials (RMs) cover a wide range of compositions, with Ba mass fractions ranging from 6.4 to 1900 µg g?1, SiO2 from 0.62% to 90.36% m/m and MgO from 0.08% to 41.03% m/m. Accuracy and precision of our data were assessed by the analyses of duplicate samples and USGS rock RMs. Barium isotopic compositions for all RMs were in agreement with each other within uncertainty. The variation of δ138/134Ba in these RMs was up to 0.7‰. The shale reference sample, affected by a high degree of chemical weathering, had the highest δ138/134Ba (0.37 ± 0.03‰), while the stream sediment obtained from a tributary draining carbonate rocks was characterised by the lowest δ138/134Ba (?0.30 ± 0.05‰). Geochemical RMs play a fundamental role in the high‐precision and accurate determination of Ba isotopic compositions for natural samples with similar matrices. Analyses of these RMs could provide universal comparability for Ba isotope data and enable assessment of accuracy for interlaboratory data.  相似文献   

4.
为完整了解华北克拉通的破坏程度和机制,加深对其西部陆块岩石圈地幔的研究十分重要,而位于华北克拉通西部集宁新生代碱性玄武岩中的地幔橄榄岩包体,为研究人员认识该地区的岩石圈地幔的性质和演化起到指示作用.运用LA-ICP-MS和LA-MC-ICP-MS对集宁地区橄榄岩矿物进行原位微区测试,获得其主量、微量元素和Sr同位素成分的数据.根据矿物组成,可以将集宁地区的橄榄岩分为两类:第一类为贫单斜辉石橄榄岩 (单斜辉石体积分数小于8%),它们经历了高程度的部分熔融,可能是古老难熔岩石圈地幔的残留;第二类为二辉橄榄岩 (单斜辉石体积分数大于13%),其熔融程度低,代表了新生饱满的岩石圈地幔.第一类橄榄岩中单斜辉石REE含量整体偏低且轻微富集LREE,第二类橄榄岩中单斜辉石具有LREE富集和轻微亏损两种配分模式,大部分样品的核边有一定的强不相容元素及Sr同位素组成变化.这些微量元素和同位素特征都表明集宁橄榄岩包体经历过交代作用.(La/Yb)N和Ti/Eu比值特征表明它们经历过多阶段的交代作用,交代介质有硅酸盐、碳酸盐熔/流体,这些交代介质可能为来源于古亚洲洋板块俯冲时释放的熔/流体.   相似文献   

5.
Laser ablation multi-collector mass spectrometry (LA-MC-ICP-MS) has emerged as the technique of choice for in situ measurements of Sr isotopes in geological minerals. However, the method poses analytical challenges and there is no widely adopted standardised approach to collecting these data or correcting the numerous potential isobaric inferences. Here, we outline practical analytical procedures and data reduction strategies to help establish a consistent framework for collecting and correcting Sr isotope measurements in geological materials by LA-MC-ICP-MS. We characterise a new set of plagioclase reference materials, which are available for distribution to the community, and present a new data reduction scheme for the Iolite software package to correct isobaric interferences for different materials and analytical conditions. Our tests show that a combination of Kr-baseline subtraction, Rb-peak-stripping using βRb derived from a bracketing glass reference material, and a CaCa or CaAr correction for plagioclase and CaCa or CaAr + REE2+ correction for rock glasses, yields the most accurate and precise 87Sr/86Sr measurements for these materials. Using the analytical and correction procedures outlined herein, spot analyses using a beam diameter of 100 μm or rastering with a 50–65 μm diameter beam can readily achieve < 100 ppm 2SE repeatability ("internal") precision for 87Sr/86Sr measurements for materials with < 1000 μg g-1 Sr.  相似文献   

6.
砂岩型铀矿微区原位U-Pb同位素定年技术方法研究   总被引:2,自引:2,他引:0  
铀矿物定年一直是成矿年代学中的难点,随着微区原位U-Pb同位素定年技术的发展,可以直接针对矿石矿物(铀矿物)进行同位素定年;但是其中的砂岩型铀矿由于其存在状态复杂,在原位定年中剥蚀要求高,也缺乏合适的外部校正标准物质,所以定年准确度有待提高。本文研究了两种微区原位U-Pb同位素测年的方法,对砂岩型铀矿定年进行了尝试,试图解决铀矿测年中的无基体匹配问题并提高砂岩型铀矿定年水平。一是建立了一种激光剥蚀多接收电感耦合等离子体质谱仪联合电子探针进行微区原位U-Pb同位素测年的技术(LA-MC-ICP-MS&EMPA)。通过优化实验方法,对秦岭陈家庄花岗岩型铀矿进行了测试,获得与同位素稀释热电离质谱法(ID-TIMS)一致的年龄结果,证明了微区原位U-Pb同位素测年无基体匹配标准物质分析的可行性;并利用此法获得鄂尔多斯盆地红庆河和塔然高勒砂岩型铀矿的微区原位U-Pb同位素年龄信息。二是尝试了利用飞秒激光剥蚀多接收电感耦合等离子体质谱法(fsLA-MC-ICP-MS)对红庆河和宁夏宁东砂岩型铀矿样品进行微区原位U-Pb同位素定年,并获得了微区原位U-Pb同位素年龄,表明飞秒激光剥蚀技术在砂岩型铀矿定年中有很好的应用前景。本文提出,比较单一且年龄偏老的单矿物样品可以选择LA-MC-ICP-MS&EMPA联合法进行分析,需要高空间分辨率的样品建议使用fsLA-MC-ICP-MS法。  相似文献   

7.
The fractionation of lithium isotopes between synthetic spodumene as representative of Li-bearing clinopyroxene and Cl- and OH-bearing aqueous fluids was experimentally determined between 500 and 900°C at 2.0 GPa. In all the experiments, 7Li was preferentially partitioned into the fluid. The fractionation is temperature dependent and approximated by the equation Δ7Li(clinopyroxene–fluid)=−4.61×(1,000/T [K]) + 2.48; R 2=0.86. Significant Li isotopic fractionation of about 1.0‰ exists even at high temperatures of 900°C. Using neutral and weakly basic fluids revealed that the amount of fractionation is not different. The Li isotopic fractionation between altered basalt and hot spring water (350°C) in natural samples is in good agreement with our experimentally determined fractionation curve. The data confirm earlier speculations drawn from the Li isotopic record of dehydrated metamorphic rocks that fluids expelled from a dehydrating slab carry heavier Li into the mantle wedge, and that a light Li component is introduced into the deeper mantle. Li and Li isotopes are redistributed among wedge minerals as fluids travel across the wedge into hotter regions of arc magma production. This modifies the Li isotopic characteristics of slab-derived fluids erasing their source memory, and explains the absence of cross-arc variations of Li isotopes in arc basalts.  相似文献   

8.
We report Li isotopic compositions, for river waters and suspended sediments, of about 40 rivers sampled within the Mackenzie River Basin in northwestern Canada. The aim of this study is to characterize the behaviour of Li and its isotopes during weathering at the scale of a large mixed lithology basin. The Mackenzie River waters display systematically heavier Li isotopic compositions relative to source rocks and suspended sediments. The range in δ7Li is larger in dissolved load (from +9.3‰ to +29.0‰) compared to suspended sediments (from −1.7‰ to +3.2‰), which are not significantly different from δ7Li values in bedrocks. Our study shows that dissolved Li is essentially derived from the weathering of silicates and that its isotopic composition in the dissolved load is inversely correlated with its relative mobility when compared to Na. The highest enrichment of 7Li in the dissolved load is reported when Li is not or poorly incorporated in secondary phases after its release into solution by mineral dissolution. This counterintuitive observation is interpreted by the mixing of water types derived from two different weathering regimes producing different Li isotopic compositions within the Mackenzie River Basin. The incipient weathering regime characterizing the Rocky Mountains and the Shield areas produces 7Li enrichment in the fluid phase that is most simply explained by the precipitation of oxyhydroxide phases fractionating Li isotopes. The second weathering regime is found in the lowland area and produces the lower δ7Li waters (but still enriched in 7Li compared to bedrocks) and the most Li-depleted waters (compared to Na). Fractionation factors suggest that the incorporation of Li in clay minerals is the mechanism that explains the isotopic composition of the lowland rivers. The correlation of boron and lithium concentrations found in the dissolved load of the Mackenzie Rivers suggests that precipitation of clay minerals is favoured by the relatively high residence time of water in groundwater. In the Shield and Rocky Mountains, Li isotopes suggest that clay minerals are not forming and that secondary minerals with stronger affinity for 7Li appear.Although the weathering mechanisms operating in the Mackenzie Basin need to be characterized more precisely, the Li isotope data reported here clearly show the control of Li isotopes by the weathering intensity. The spatial diversity of weathering regimes, resulting from a complex combination of factors such as topography, geology, climate and hydrology explains, in fine, the spatial distribution of Li isotopic ratios in the large drainage basin of the Mackenzie River. There is no simple relationship between Li isotopic composition and chemical denudation fluxes in the Mackenzie River Basin.  相似文献   

9.
Six tourmaline samples were investigated as potential reference materials (RMs) for boron isotope measurement by secondary ion mass spectrometry (SIMS). The tourmaline samples are chemically homogeneous and cover a compositional range of tourmaline supergroup minerals (primarily Fe, Mg and Li end‐members). Additionally, they have homogeneous boron delta values with intermediate precision values during SIMS analyses of less than 0.6‰ (2s). These samples were compared with four established tourmaline RMs, that is, schorl IAEA‐B‐4 and three Harvard tourmalines (schorl HS#112566, dravite HS#108796 and elbaite HS#98144). They were re‐evaluated for their major element and boron delta values using the same measurement procedure as the new tourmaline samples investigated. A discrepancy of about 1.5‰ in δ11B was found between the previously published reference values for established RMs and the values determined in this study. Significant instrumental mass fractionation (IMF) of up to 8‰ in δ11B was observed for schorl–dravite–elbaite solid solutions during SIMS analysis. Using the new reference values determined in this study, the IMF of the ten tourmaline samples can be modelled by a linear combination of the chemical parameters FeO + MnO, SiO2 and F. The new tourmaline RMs, together with the four established RMs, extend the boron isotope analysis of tourmaline towards the Mg‐ and Al‐rich compositional range. Consequently, the in situ boron isotope ratio of many natural tourmalines can now be determined with an uncertainty of less than 0.8‰ (2s).  相似文献   

10.
In situ laser ablation analyses rely on the microanalytical homogeneity of reference materials (RMs) and a similar matrix and mass fraction between unknown samples and RMs to obtain reliable results. Suitable carbonate and phosphate RMs for determination of Sr isotope ratios in such materials are limited. Thus, we determined 87Sr/86Sr ratios of several carbonate (JCt‐1, JCp‐1, MACS‐1, MACS‐3) and phosphate (MAPS‐4, MAPS‐5, NIST SRM 1400, NIST SRM 1486) international RMs using dissolved samples and two different multi‐collector inductively coupled plasma‐mass spectrometers (MC‐ICP‐MS). Our Sr isotope data are in agreement with published data and have an improved measurement precision for some RMs. For MACS‐1, we present the first 87Sr/86Sr value. We tested the suitability of these materials for microanalytical analyses by LA‐MC‐ICP‐MS, with two different laser ablation systems: a conventional nanosecond laser and a state‐of‐the‐art femtosecond laser. We investigated the RMs micro‐homogeneity and compared the data with our solution data. Both laser ablation systems yielded identical 87Sr/86Sr ratios within uncertainty to the solution data for RMs with low interferences of REEs. Therefore, these carbonate and phosphate RMs can be used to achieve accurate and precise results for in situ Sr isotope investigations by LA‐MC‐ICP‐MS of similar materials.  相似文献   

11.
The fractionation of lithium isotopes among quartz, muscovite, and a chloride-bearing aqueous fluid has been investigated experimentally at 400°-500°C and 50-100 MPa. Experiments were performed for 15-60 days in cold seal vessels with natural mineral specimens. Lithium was introduced primarily through the fluid, which also contained KCl and HCl. In most runs, the fluid was prepared with the L-SVEC standard (δ7Li = 0) and was 1 M in total chloride with K/Li/H = 100/10/1. In two experiments, a 6Li spike was employed. The experiments demonstrate that quartz and muscovite are susceptible to pronounced, rapid shifts in Li isotopic composition by diffusion through interaction with a Li-bearing fluid, particularly at 500°C. At 500°C, fractionation factors were determined to be Δquartz-aqueous ≅ +8 to + 12‰ and Δmuscovite-aqueous ≅ +18 to + 20‰. An intermineral fractionation factor is given by Δmuscovite-quartz ≈ +9‰. At 400°C, the results suggest Δquartz-aqueous ≈ +4 to + 6‰. The study provides evidence of systematic fractionation in lithium isotopes at the temperatures of some magmatic processes, such as those associated with porphyry-type ore systems and pegmatites.  相似文献   

12.
The Madi rare metal granite is a complex massif, which contains a variety of rare metals, such as Nb, Ta, Li, and Be. In this paper, the geochemical characteristics of the granite were obtained by multi-collector inductively coupled mass spectrometry (MC-ICP-MS). The precise crystalline age of the granite was obtained from monazite U-Pb dating, and the source of the granite was determined using Li-Nd isotopes. The Madi rare metal granite is a high-K (calc-alkaline), peraluminous, S-type granite. The U-Pb monazite age indicates that the crystalline age of the granite is 175.6 Ma, which is Early Jurassic. The granite is characterized by a relatively wide range of δ7Li values (+2.99‰ to +5.83‰) and high lithium concentrations (181 ppm to 1022 ppm). The lithium isotopic composition of the granite does not significantly correlate with the degree of magmatic differentiation. An insignificant amount of lithium isotope fractionation occurred during the granitic differentiation. The lithium isotopic composition of the granite significantly differs from that of the wall rock, but it is very similar to that of a primitive mantle peridotite xenolith (mean δ7Li value +3.5‰). The plot of Li concentration versus δ7Li indicates that the Li isotopic composition of the granite is similar to that of island arc lavas. Based on the above-described evidence, the granite was mainly derived from the crust, but it was contaminated by a deep granitic magma.  相似文献   

13.
New zircon reference materials for in situ zircon radiogenic Hf isotope and stable Zr isotopic determinations made by laser ablation multi-collector inductively coupled plasma-mass spectrometry (LA-MC-ICP-MS) are required due to high data productivity and consequently high reference material consumption rate. This study examines a new natural zircon for Zr isotope ratios by double spike thermal ionisation mass spectrometry (TIMS), and for Hf isotopes by bulk solution nebuliser (SN)-MC-ICP-MS with both Zr and Hf determined by LA-MC-ICP-MS. A total of five zirconium isotope measurements from drilled zircons, determined by TIMS, yield a mean δ94/90ZrIPGP-Zr value of -0.09 ± 0.06‰ (2s). Five and eight hafnium isotope measurements for powders from the drilled zircons and Ban-1-4 by SN-MC-ICP-MS, yield mean 176Hf/177Hf ratios of 0.282985 ± 0.000011 (2s) and 0.282982 ± 0.000007 (2s), respectively. The mean δ94/90ZrIPGP-Zr value and 176Hf/177Hf ratio determined by LA-MC-ICP-MS analyses are -0.06 ± 0.09‰ (2s, n = 504) and 0.282985 ± 0.000035 (2s, n = 327), respectively. The isotopic homogeneities suggest that the Ban-1 zircon is a suitable reference material for microbeam Zr and Hf isotopic measurements.  相似文献   

14.
Measuring Hg Isotopes in Bio-Geo-Environmental Reference Materials   总被引:1,自引:0,他引:1  
With the emergence of new analytical techniques and the expansion of scientific fields explored by using mercury isotopes, the community needs reference materials (RM) to validate and assure the accuracy of the results. The present work investigates (1) the characterisation of secondary RM in order to validate analytical systems, (2) the effects of two complex matrices on isotopic determination using stannous chloride cold vapour generation coupled to MC-ICP-MS (CV-MC-ICP-MS), (3) the effects of multiple digestion techniques for total Hg extraction and (4) the characterisation of nine geo-bio-environmental RM. Two secondary mono-elemental RMs analysed using two different analytical setups yielded isotopic compositions on δ202Hg of −3.54 ± 0.27‰ (CRPG-F65A, 2SD, n = 38) and +2.59 ± 0.19‰ (CRPG-RL24H, 2SD, n = 30) relative to the CRM NIST SRM 3133. These two RMs cover the whole range of Hg isotopic fractionation in natural samples and are made available to the scientific community. Complex fly ash and hydroxysulfate green rust matrices were synthesised, spiked with NIST SRM 3133, then digested and finally analysed versus the mono-elemental NIST SRM 3133 to show potential effect of these complex matrices during CV-MC-ICP-MS. Three digestions techniques, including traditional acid digestion, microwave digestion and high pressure-high temperature digestion, were applied to the lichen RM BCR-482 in order to compare advantages and drawbacks of these methods. Finally, the isotopic compositions of nine RMs including soils (NIST SRM 2711; GXR-2; GSS-4), sediment (GSD-10), jasperoid (GXR-1), ore deposit (GXR-3), fly ashes (BCR-176; BCR-176R) and lichen (BCR-482) are reported. These selected materials have δ202Hg values ranging from −1.75‰ to +0.11‰. Some RMs also presented mass-independent fractionation with Δ199Hg and Δ201Hg of up to −0.6‰.  相似文献   

15.
目前应用LA-MC-ICPMS分析熔体包裹体Pb同位素,由于没有同时测试U和Th的信号,导致熔体包裹体Pb同位素的研究仅局限于中生代以来的样品。本文应用LA-MC-ICPMS分析了玻璃样品以及存在显著U-Th衰变影响的古老熔体包裹体的Pb同位素组成,评价了U/Pb和Th/Pb分析误差对初始Pb同位素比值校正的影响。实验中以国际玻璃标样NKT-1G为外部标样,采用"标样-样品-标样法"进行仪器漂移和质量歧视校正,结果表明,国际玻璃标样BHVO-2G、TB-1G的208Pb/206Pb和207Pb/206Pb分析精度优于0.30%(2RSD),与推荐值的偏差小于0.30%,然而232Th/206Pb和238U/206Pb分析结果显示了较大分散性(外精度约5.0%)。根据误差传递计算,样品的年龄对初始铅的误差有很大影响。对于古生代以来的样品(年龄小于540 Ma),即使测试的232Th/206Pb和238U/206Pb与真值偏差达到10%,经过U-Th衰变校正后的Pb同位素比值与真值的偏差依然小于0.80%。因此本方法可以将熔体包裹体等地质样品的Pb同位素研究由新生代样品(年龄小于65 Ma)扩展到古生代样品。  相似文献   

16.
Recent developments from 2008 to 2009 in ICP-MS engineering, methods and applications are reviewed here. Of particular emphasis are advances in: (a) maximising sensitivity and reducing elemental/isotopic fractionation during laser ablation processing; (b) developing new analytical techniques to measure major, minor and trace element abundances without depending on matrix-matched calibrating materials, pre-determined internal standard concentrations and/or multiple analytical methods; (c) applying in situ and solution-based ICP-MS techniques to the analysis of forensic materials for criminal and/or nuclear investigations; and (d) improving precision and limits of detection of laser ablation multi-collector ICP-MS measurements of (ultra) trace elemental and isotopic abundances.  相似文献   

17.
Different batches of the new US Geological Survey (USGS) reference materials (RMs) BCR-2, BHVO-2, AGV-2, DTS-2 and GSP-2 and the original USGS RMs BCR-1, BHVO-1, AGV-1, DTS-1 and GSP-1 have been analysed by isotope dilution using thermal ionisation mass spectrometry (ID-TIMS) and by multi-ion counting spark source mass spectrometry (MIC-SSMS). The concentrations of K, Rb, Sr, Ba and the rare earth elements were determined with overall analytical uncertainties of better than 1% (ID-TIMS) and 3% (MIC-SSMS). The analyses of different aliquots and batches of BCR-2, BHVO-2, AGV-2 and GSP-2, respectively, agree within 1%, i.e. approximately the analytical uncertainties of the data. This indicates an homogeneous distribution of the trace elements in these RMs. Differences in element concentrations of up to 17% in different aliquots of the depleted RM DTS-2 are outside the analytical uncertainty of our data. They may be attributed to a slightly heterogeneous distribution of trace elements in this dunite sample. Our trace element data for BCR-2, BHVO-2, AGV-2 and GSP-2 agree within about 3% with preliminary reference values published by the USGS. They also agree within 1-6% with those of the original RMs BCR-1, BHVO-1, AGV-1 and GSP-1. Large compositional differences are found between DTS-2 and DTS-1, where the concentrations of K, Rb, Sr and the light REE differ by factors of 2 to 24.  相似文献   

18.
The CRPG (Nancy, France) has prepared secondary reference materials for Li isotope measurements by mixing 7Li or 6Li spikes and either L-SVEC or IRMM-016 certified reference materials to produce solutions having a known Li concentration and isotopic composition. The Li7-N and Li6-N solution samples (1.5 mol l−1 HNO3) have nominal δ7Li isotopic compositions of 30.1‰ and -9.7‰ respectively relative to L-SVEC and concentrations of 100 mg l−1. Repeated measurement of these samples using the QUAD-ICP-MS at the CRPG yielded δ7Li of 30.4 ± 1.1‰ (n = 13) and -8.9 ± 0.9‰ (n = 9) at the 2s level of confidence. An additional LiCl-N solution was measured and yielded a delta value of 9.5 ± 0.6‰ (n = 3). Identical results were obtained at the BRGM (Orléans, France) from determinations performed with a Neptune MC-ICP-MS (30.2 ± 0.3‰, n = 89 for the Li7-N, -8.0 ± 0.3‰, n = 38 for the Li6-N and 10.1 ± 0.2‰, n = 46 for LiCl-N at the 2s level of confidence). The deviation of measured composition relative to the nominal value for the Li6-N solution might be explained by either contamination during preparation or an error during sample weighing. These secondary reference materials, previously passed through ion exchange resin or directly analysed, may be used for checking the accuracy of Li isotopic measurements over a range of almost 40‰ and will be available to the scientific community upon request to J. Carignan or N. Vigier, CRPG.  相似文献   

19.
Uncertainty for elemental and isotopic measurements in calcite by LA‐ICP‐MS is largely controlled by the homogeneity of the reference materials (RMs) used for calibration and validation. In order to produce calcite RMs with homogeneous elemental and isotopic compositions, we incorporated elements including U, Pb and rare earth elements into calcite through heat‐ and pressure‐induced crystallisation from amorphous calcium carbonate that was precipitated from element‐doped reagent solution. X‐ray absorption spectra showed that U was present as U(VI) in the synthesised calcite, probably with a different local structure from that of aqueous uranyl ions. The uptake rate of U by our calcite was higher in comparison with synthetic calcite of previous studies. Variations of element mass fractions in the calcite were better than 12% 2RSD, mostly within 7%. The 207Pb/206Pb ratio in the calcite showed < 1% variations, while the 238U/206Pb ratio showed 3–24% variations depending on element mass fractions. Using the synthetic calcite as primary RMs, we could date a natural calcite RM, WC‐1, with analytical uncertainty as low as < 3%. The method presented can be useful to produce calcite with controlled and homogeneous element mass fractions and is a promising alternative to natural calcite RMs for U‐Pb geochronology.  相似文献   

20.
The intraplate volcanic suite of the Chaîne des Puys (French Massif Central) shows a complete petrologic range, from alkali basalts to trachytes. The significant variations of trace elements and radiogenic isotopes along the series strongly support the occurrence of crustal assimilation associated with fractional crystallization (AFC). The least contaminated basalts are clearly related to a HIMU-type reservoir (206Pb/204Pb > 19.6; 87Sr/86Sr < 0.7037; εNd > + 4). The behavior of radiogenic isotopes suggests that the most likely crustal contaminants are meta-sediments located in the lower crust.The Li isotopic compositions of the lavas range from high δ7Li (> + 7‰) in basalts to lighter values in more evolved lavas (down to δ7Li ≈ 0‰). The mantle component, expressed in the least evolved lavas, has a heavy Li isotopic signature, in good agreement with previous δ7Li measurements of OIB lavas with HIMU affinities. The evolution of Li isotopic compositions throughout the volcanic series is in agreement with the AFC model suggested by the Sr–Nd–Pb isotopic systems. Although the behavior of Li isotopes during assimilation processes is currently poorly constrained, our calculations suggest that at least a portion of the lower crust beneath the Chaîne des Puys is characterized by a light Li isotopic composition (δ7Li < − 5‰).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号