首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A thin layer of fine‐grained sediment commonly is deposited at the sediment–water interface of streams and rivers during low‐flow conditions, and may hinder exchange at the sediment–water interface similar to that observed at many riverbank‐filtration (RBF) sites. Results from a numerical groundwater‐flow model indicate that a low‐permeability veneer reduces the contribution of river water to a pumping well in a riparian aquifer to various degrees, depending on simulated hydraulic gradients, hydrogeological properties, and pumping conditions. Seepage of river water is reduced by 5–10% when a 2‐cm thick, low‐permeability veneer is present on the bed surface. Increasing thickness of the low‐permeability layer to 0·1 m has little effect on distribution of seepage or percentage contribution from the river to the pumping well. A three‐orders‐of‐magnitude reduction in hydraulic conductivity of the veneer is required to reduce seepage from the river to the extent typically associated with clogging at RBF sites. This degree of reduction is much larger than field‐measured values that were on the order of a factor of 20–25. Over 90% of seepage occurs within 12 m of the shoreline closest to the pumping well for most simulations. Virtually no seepage occurs through the thalweg near the shoreline opposite the pumping well, although no low‐permeability sediment was simulated for the thalweg. These results are relevant to natural settings that favour formation of a substantial, low‐permeability sediment veneer, as well as central‐pivot irrigation systems, and municipal water supplies where river seepage is induced via pumping wells. Published in 2011 by John Wiley & Sons, Ltd.  相似文献   

2.
Decline in regional water tables (RWT) can cause losing streams to disconnect from underlying aquifers. When this occurs, an inverted water table (IWT) will develop beneath the stream, and an unsaturated zone will be present between the IWT and the RWT. The IWT marks the base of the saturated zone beneath the stream. Although a few prior studies have suggested the likelihood of an IWT without a clogging layer, most of them have assumed that a low‐permeability streambed is required to reduce infiltration from surface water to groundwater, and that the IWT only occurs at the bottom of the low‐permeability layer. In this study, we use numerical simulations to show that the development of an IWT beneath an unclogged stream is theoretically possible under steady‐state conditions. For a stream width of 1 m above a homogeneous and isotropic sand aquifer with a 47 m deep RWT (measured in an observation point 20 m away from the center of the stream), an IWT will occur provided that the stream depth is less than a critical value of 4.1 m. This critical stream depth is the maximum water depth in the stream to maintain the occurrence of an IWT. The critical stream depth decreases with stream width. For a stream width of 6 m, the critical stream depth is only 1 mm. Thus while theoretically possible, an IWT is unlikely to occur at steady state without a clogging layer, unless a stream is very narrow or shallow and the RWT is very deep.  相似文献   

3.
Artificial recharge through a thick, heterogeneous unsaturated zone   总被引:2,自引:0,他引:2  
Thick, heterogeneous unsaturated zones away from large streams in desert areas have not previously been considered suitable for artificial recharge from ponds. To test the potential for recharge in these settings, 1.3 x 10(6) m(3) of water was infiltrated through a 0.36-ha pond along Oro Grande Wash near Victorville, California, between October 2002 and January 2006. The pond overlies a regional pumping depression 117 m below land surface and is located where thickness and permeability of unsaturated deposits allowed infiltration and saturated alluvial deposits were sufficiently permeable to allow recovery of water. Because large changes in water levels caused by nearby pumping would obscure arrival of water at the water table, downward movement of water was measured using sensors in the unsaturated zone. The downward rate of water movement was initially as high as 6 m/d and decreased with depth to 0.07 m/d; the initial time to reach the water table was 3 years. After the unsaturated zone was wetted, water reached the water table in 1 year. Soluble salts and nitrate moved readily with the infiltrated water, whereas arsenic and chromium were less mobile. Numerical simulations done using the computer program TOUGH2 duplicated the downward rate of water movement, accumulation of water on perched zones, and its arrival at the water table. Assuming 10 x 10(6) m(3) of recharge annually for 20 years, a regional ground water flow model predicted water level rises of 30 m beneath the ponds, and rises exceeding 3 m in most wells serving the nearby urban area.  相似文献   

4.
Abstract

A pumping test was conducted along the Mullica River in the Wharton Tract, New Jersey as part of a water-resources investigation. Impermeable bog iron caps parts of the flood plain and channel so that ground-water recharge moves directly into the river.

Observation wells on both sides of the river tapped water-bearing zones at 25 (shallow), 50 (medium), and 100 (deep) feet. A pumping well, screened in the medium zone, caused abrupt drawdowns which leveled off after a few minutes. Shape of the drawdown cone established early and changed little throughout the test. Piezometric surfaces were steepest on the southwest, indicating that most water came from there. Uninterrupted contour trends beneath the river show that here relatively little water entered the aquifer. Head differentials between the zones were greatest at the pumping well. Movement from the deep to medium zones was confined largely to the pumping-well vicinity. Pumping produced extensive reductions in the original areas of upward gradient between the medium and shallow zones; thus, areas of downward leakage became connected across the river. Piezometric head beneath the river was progressively lowered and caused the flood plain to dry; it became wet again when pumping stopped. The well field recovered to natural conditions in about 24 hours.

Lack of hydraulic continuity between the river and aquifer results from bog iron deposits. Their removal will improve the continuity, and it appears feasible to induce river recharge to nearby pumping wells.  相似文献   

5.
Analytical studies for well design adjacent to river banks are the most significant practical task in cases involving the efficiency of riverbank filtration systems. In times when high pollution of river water is joined with increasing water demand, it is necessary to design pumping wells near the river that provide acceptable amounts of river water with minimum contaminant concentrations. This will guarantee the quality and safety of drinking water supplies. This article develops an analytical solution based on the Green's function approach to solve an inverse problem: based on the required level of contaminant concentration and planned pumping time period, the shortest distance to the riverbank that has the maximum percentage of river water is determined. This model is developed in a confined and homogenous aquifer that is partially penetrated by the stream due to the existence of clogging layers. Initially, the analytical results obtained at different pumping times, rates and with different values of initial concentration are checked numerically using the MODFLOW software. Generally, the distance results obtained from the proposed model are acceptable. Then, the model is validated by data related to two pumping wells located at the first riverbank filtration pilot project conducted in Malaysia.  相似文献   

6.
Horizontal wells or radial collector wells are used in shallow aquifers to enhance water withdrawal rates. Groundwater flow patterns near these wells are three-dimensional (3D), but difficult to represent in a 3D numerical model because of the high degree of grid refinement needed. However, for the purpose of designing water withdrawal systems, it is sufficient to obtain the correct production rate of these wells for a given drawdown. We developed a Cauchy boundary condition along a horizontal well in a Dupuit-Forchheimer model. Such a steady-state 2D model is not only useful for predicting groundwater withdrawal rates but also for capture zone delineation in the context of source water protection. A comparison of our Dupuit-Forchheimer model for a radial collector well with a 3D model yields a nearly exact production rate. Particular attention is given to horizontal wells that extend underneath a river. A comparison of our approach with a 3D solution for this case yields satisfactory results, at least for moderate-to-large river bottom resistances.  相似文献   

7.
The article presents semi‐analytical mathematical models to asses (1) enhancements of seepage from a canal and (2) induced flow from a partially penetrating river in an unconfined aquifer consequent to groundwater withdrawal in a well field in the vicinity of the river and canal. The nonlinear exponential relation between seepage from a canal reach and hydraulic head in the aquifer beneath the canal reach is used for quantifying seepage from the canal reach. Hantush's (1967) basic solution for water table rise due to recharge from a rectangular spreading basin in absence of pumping well is used for generating unit pulse response function coefficients for water table rise in the aquifer. Duhamel's convolution theory and method of superposition are applied to obtain water table position due to pumping and recharge from different canal reaches. Hunt's (1999) basic solution for river depletion due to constant pumping from a well in the vicinity of a partially penetrating river is used to generate unit pulse response function coefficients. Applying convolution technique and superposition, treating the recharge from canal reaches as recharge through conceptual injection wells, river depletion consequent to variable pumping and recharge is quantified. The integrated model is applied to a case study in Haridwar (India). The well field consists of 22 pumping wells located in the vicinity of a perennial river and a canal network. The river bank filtrate portion consequent to pumping is quantified.  相似文献   

8.
Disconnected Surface Water and Groundwater: From Theory to Practice   总被引:1,自引:0,他引:1  
When describing the hydraulic relationship between rivers and aquifers, the term disconnected is frequently misunderstood or used in an incorrect way. The problem is compounded by the fact that there is no definitive literature on the topic of disconnected surface water and groundwater. We aim at closing this gap and begin the discussion with a short introduction to the historical background of the terminology. Even though a conceptual illustration of a disconnected system was published by Meinzer (1923) , it is only within the last few years that the underlying physics of the disconnection process has been described. The importance of disconnected systems, however, is not widely appreciated. Although rarely explicitly stated, many approaches for predicting the impacts of groundwater development on surface water resources assume full connection. Furthermore, management policies often suggest that surface water and groundwater should only be managed jointly if they are connected. However, although lowering the water table beneath a disconnected section of a river will not change the infiltration rate at that point, it can increase the length of stream that is disconnected. Because knowing the state of connection is of fundamental importance for sustainable water management, robust field methods that allow the identification of the state of connection are required. Currently, disconnection is identified by showing that the infiltration rate from a stream to an underlying aquifer is independent of the water table position or by identifying an unsaturated zone under the stream. More field studies are required to develop better methods for the identification of disconnection and to quantify the implications of heterogeneity and clogging processes in the streambed on disconnection.  相似文献   

9.
The three-dimensional groundwater flow patterns in a gravel bar at the Danube east of Vienna were investigated and are discussed in this paper. The observed groundwater level gradients are highly dynamic and respond very quickly to changes in the river water levels. A variably saturated groundwater model was calibrated to the data to describe the complex dynamics of flow in the gravel bar. The model results suggest that short-term (6–48 h) fluctuations of river water levels cause variations in the exchange flow rates from − 35 l/s to 82 l/s. The highest rates occur during brief infiltration after rapidly rising river water levels. Simulations of different scenarios indicate that riverbank clogging will decrease the exchange fluxes by up to 80%, while clogging of both riverbank and riverbed essentially stops the flow exchange. The groundwater model is also used to simulate the transport of a conservative tracer. The variation of river water levels over time is shown to increase the extent of the active river–aquifer mixing zone in the gravel bar. These dynamic factors significantly enhance the dilution of conservative tracer concentrations in this zone.  相似文献   

10.
A confined aquifer may become unconfined near the pumping wells when the water level falls below the confining unit in the case where the pumping rate is great and the excess hydraulic head over the top of the aquifer is small. Girinskii's potential function is applied to analyze the steady ground water flow induced by pumping wells with a constant-head boundary in a mixed confined-unconfined aquifer. The solution of the single-well problem is derived, and the critical radial distance at which the flow changes from confined to unconfined condition is obtained. Using image wells and the superposition method, an analytic solution is presented to study steady ground water flow induced by a group of pumping wells in an aquifer bounded by a river with constant head. A dimensionless function is introduced to determine whether a water table condition exists or not near the pumping wells. An example with three pumping wells is used to demonstrate the patterns of potentiometric surface and development of water table around the wells.  相似文献   

11.
Identification of the pumping influences at monitoring wells caused by spatially and temporally variable water supply pumping can be a challenging, yet an important hydrogeological task. The information that can be obtained can be critical for conceptualization of the hydrogeological conditions and indications of the zone of influence of the individual pumping wells. However, the pumping influences are often intermittent and small in magnitude with variable production rates from multiple pumping wells. While these difficulties may support an inclination to abandon the existing dataset and conduct a dedicated cross‐hole pumping test, that option can be challenging and expensive to coordinate and execute. This paper presents a method that utilizes a simple analytical modeling approach for analysis of a long‐term water level record utilizing an inverse modeling approach. The methodology allows the identification of pumping wells influencing the water level fluctuations. Thus, the analysis provides an efficient and cost‐effective alternative to designed and coordinated cross‐hole pumping tests. We apply this method on a dataset from the Los Alamos National Laboratory site. Our analysis also provides (1) an evaluation of the information content of the transient water level data; (2) indications of potential structures of the aquifer heterogeneity inhibiting or promoting pressure propagation; and (3) guidance for the development of more complicated models requiring detailed specification of the aquifer heterogeneity.  相似文献   

12.
Infiltration capacity of bank filtration systems depends on water extraction and hydraulic resistance of the bed sediments. Lakebed hydraulics may be especially affected by clogging, which is dependent on settlement of fine particles, redox potential, and other factors. In the field, most of these processes are difficult to quantify, and thus, when calculating response to pumping the water flux across the sediment surface is assumed to be linearly dependent on the hydraulic gradient. However, this assumption was not adequate to describe conditions at a bank filtration site located at Lake Tegel, Berlin, Germany. Hence, we first assumed the leakage coefficient (or leakance) is spatially distributed and also temporally variant. Furthermore, observations show that the leakance is considerably higher in shallow than in deeper areas; hence, leakance was assumed to be dependent on the existence and thickness of an unsaturated zone below the lake. The proposed explanation of spatial and temporal variability in leakance involves a hypothesis for redox dependent and reversible biogeochemical clogging, supported by geochemical observations in surface water and ground water. Four leakance approaches are implemented in the ground water flow code MODFLOW2000 and calibrated by inverse modeling using the parameter estimation software PEST. These concepts are evaluated by examining the fit to the hydraulic heads, to infiltration measurements, transport modeling results, and considering the degrees of freedom due to the number of calibration parameters. The leakage concept based on the assumption of the influence of an unsaturated zone on clogging processes best explains the field data.  相似文献   

13.
Siting wells near streams requires an accurate estimate of the quantity of water derived from the river due to pumping. A number of hydrogeological and hydraulic parameters influence this value. This study estimates stream depletion under steady-state conditions for a variety of hydrogeological systems. A finite differences model was used to analyze several hydrogeological situations, and for each of these the stream depletion was estimated using an advective transport method. An empirical equation for stream depletion was obtained for the case of a stream that partially penetrates the aquifer and a pumping well that is screened over a portion of the aquifer. The derived equation, which is valid for both isotropic and anisotropic conditions, expresses stream depletion as a function of the unit inflow to the river, the discharge of the pumping well, the well screen length, the distance between the river and pumping well, the wetted perimeter, and a new parameter called "overlap," which is defined to be the distance between the riverbed and the top of well screen. The overlap parameter makes it possible to consider indirectly the vertical component of flow, which is accentuated when the well is screened below the streambed. The formula proposed here should be useful in deciding where to locate a pumping well and to decide the appropriate length of its screen.  相似文献   

14.
Zheming Shi  Guangcai Wang 《水文研究》2015,29(12):2659-2667
We analyse the groundwater level changes following the Wenchuan earthquake in three wells – NX, DZ and BBLY – located in the same fault zone, in the near field (distance of ~300 km from the epicentre). Co‐seismic falls in the water level and gradual recovery were recorded in these wells but with different recovery periods (from 200 days to more than 1600 days). The response of the groundwater level to Earth tides is used as a proxy to explore the permeability evolution. We found that the permeability increased in response to the Wenchuan earthquake in the three wells but with different post‐earthquake recovery processes. Only BBLY recovered to its pre‐earthquake value 260 days after the Wenchuan earthquake and remained stable. The permeability in NX returned to its pre‐earthquake value over a similar period but then continued to drop. The permeability in DZ returned to its pre‐earthquake value much quicker than that in the other two wells and remained stable below the pre‐earthquake value 200 days after the earthquake. This suggests that the groundwater level changes in the three wells were mainly caused by permeability changes. In the BBLY well, the unclogging/clogging of the fracture flow path mechanism may explain the permeability evolution, whereas mechanisms such as unclogging/clogging or the opening/closing of the fracture associated with blocking of the narrow fracture apertures appears to be responsible for the permeability evolution in the NX and DZ wells. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
Water level changes in wells provide a direct measure of the impact of groundwater development at a scale of relevance for management activities. Important information about aquifer dynamics and an aquifer's future is thus often embedded in hydrographs from continuously monitored wells. Interpretation of those hydrographs using methods developed for pumping‐test analyses can provide insights that are difficult to obtain via other means. These insights are demonstrated at two sites in the High Plains aquifer in western Kansas. One site has thin unconfined and confined intervals separated by a thick aquitard. Pumping‐induced responses in the unconfined interval indicate a closed (surrounded by units of relatively low permeability) system that is vulnerable to rapid depletion with continued development. Responses in the confined interval indicate that withdrawals are largely supported by leakage. Given the potential for rapid depletion of the unconfined interval, the probable source of that leakage, it is likely that large‐scale irrigation withdrawals will not be sustainable in the confined interval beyond a decade. A second site has a relatively thick unconfined aquifer with responses that again indicate a closed system. However, unlike the first site, previously unrecognized vertical inflow can be discerned in data from the recovery periods. In years of relatively low withdrawals, this inflow can produce year‐on‐year increases in water levels, an unexpected occurrence in western Kansas. The prevalence of bounded‐aquifer responses at both sites has important ramifications for modeling studies; transmissivity values from pumping tests, for example, must be used cautiously in regional models of such systems.  相似文献   

16.
In this study, we use borehole temperature data and stable isotopes to delineate the flow system and estimate the effect of urbanization in the Nagaoka area of Japan. Temperature profiles were measured four times in observation wells during the period 2000-2001 and compared with those measured in the same wells during the period 1977-1983 (Taniguchi 1986). Water was sampled in both observation and pumping wells during the same period. The temporal and spatial variability in temperature indicate clearly the effect of urban warming and heavy pumping on the ground water system. Urban warming caused higher temperatures recently as compared to the older values, and pumping caused induced recharge from the river to the ground water. The stable isotope data show the ground water flow system is divided into shallow, intermediate, and deep systems, and that land use and infiltration rate are affecting the shallow flow system.  相似文献   

17.
The flow magnitude and timing from hydroelectric dams in the Snake River Basin of the Pacific north‐western US is managed in part for the benefit of salmon. The objective of this research was to evaluate the effects of Hells Canyon Dam discharge operations on hydrologic exchange flows between the river and riverbed in Snake River fall Chinook salmon spawning areas. Interactions between river water and pore water within the upper 1 m of the riverbed were quantified through the use of self‐contained temperature and water level data loggers suspended inside of piezometers. The data were recorded at 20 min intervals over a period of 200 days when the mean daily discharge was 218–605 m3 s?1, with hourly stage changes as large as 1·9 m. Differences in head pressure between the river and riverbed were small, often within ± 2 cm. Measured temperature gradients in the riverbed indicated significant interactions between the surface and subsurface water. At the majority of sites, neither hydraulic nor temperature gradients were significantly affected by either short‐ or long‐term changes in discharge operations from Hells Canyon Dam. Only 2 of 14 study sites exhibited acute flux reversals between the river and riverbed resulting from short‐term, large magnitude changes in discharge. The findings suggest that local scale measurements may not be wholly explanatory of the hydrological exchange between the river and riverbed. The processes controlling surface water exchange at the study sites are likely to be bedform‐induced advective pumping, turbulence at the riverbed surface, and large‐scale hydraulic gradients along the longitudinal profile of the riverbed. By incorporating the knowledge of hydrological exchange processes into water management planning, regional agencies will be better prepared to manage the limited water resources among competing priorities that include salmon recovery, flood control, irrigation supply, hydropower production, and recreation. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

18.
Chenaf D  Chapuis RP 《Ground water》2007,45(2):168-177
When a fully penetrating well pumps an ideal unconfined aquifer at steady state, the water table usually does not join the water level in the well. There is a seepage face inside the well, which is a key element in evaluating the well performance. This problem is analyzed using the finite-element method, solving the complete equations for saturated and unsaturated flow. The seepage face position is found to be almost independent of the unsaturated zone properties. The numerical results are used to test the validity of several analytic approximations. Equations are proposed to predict the seepage face position at the pumping well for any well drawdown, and the water table position at any distance from the pumping well for any in-well drawdown. Practical hints are provided for installing monitoring wells and evaluating well efficiency.  相似文献   

19.
Riverbank filtration (RBF) has been widely used throughout the world as an effective means to regulate surface water and groundwater resources and pretreat raw water for municipal water supply. The quality of the water from a riverside well field and the mixing ratios of surface water and groundwater is primarily impacted by the hydrodynamic processes in the RBF system. The RBF system is largely controlled by the water exploiting system in addition to the natural hydrologic condition of the river–aquifer system. As one of the most important design parameters of the riverside well field, the drawdown of groundwater level greatly determines the water head differences between the river water and groundwater as well as the field flow net, which subsequently impacts the mixing of river water and groundwater and water quality significantly. This study aimed to improve the understanding of the mixing process between the surface water and groundwater and estimate the impact of the RBF on the mixing ratio of surface water–groundwater and water quality quantitatively. A set of field pumping tests with various groundwater level drawdowns were carried out independently and successively at a riverside field with a single pumping well near the Songhua River in Northeast China in August 2017. During these tests, the water levels and hydrochemical parameters of the Songhua River, the adjacent aquifer, and the pumping well were monitored. The dynamic mixing process of the river water and groundwater and water quality under various drawdown conditions were analysed systematically using analytical methods. The results obtained from Dupuit method and the Mirror Image method in conjunction with the Hydrochemical Tracing method showed that the pumping water directly from the river water reached 60% ± 10% after a steady flow net was established. The larger the proportion of the pumping water captured from the river, the better quality of the pumping water was, because the quality of the river water (only limited to some water quality parameters monitored which were minority) was better than that of the groundwater. The results also showed that total Fe, TDS, total hardness, CODMn, and K+ were relatively sensitive to the changes of groundwater drawdown, and their concentrations decreased with an increase in the groundwater drawdown. It can be concluded that both the mixing ratio of the surface water and the groundwater and the water quality of the riverside well field can be regulated through adjusting the designed drawdown of the groundwater level, which is helpful for the design and the optimization of the riverside well water intake engineering.  相似文献   

20.
Fault zones are an important control on fluid flow, affecting groundwater supply, contaminant migration, and carbon storage. However, most models of fault seal do not consider fault zone cementation, despite the recognition that it is common and can dramatically reduce permeability. In order to study the field-scale hydrogeologic effects of fault zone cementation, we conducted a series of aquifer pumping tests in wells installed within tens of meters of the variably cemented Loma Blanca Fault, a normal fault in the Rio Grande Rift. In the southern half of the study area, the fault zone is cemented by calcite; the cemented zone is 2-8 m wide. In the center of the study area, the cemented fault zone is truncated at a buttress unconformity that laterally separates hydrostratigraphic units with a ∼40X difference in permeability. The fault zone north of the unconformity is not cemented. Constant rate pumping tests indicate that where the fault is cemented, it is a barrier to groundwater flow. This is an important demonstration that a fault with no clay in its core and similar sediment on both sides can be a barrier to groundwater flow by virtue of its cementation; most conceptual models for the hydrogeology of faults would predict that it would not be a barrier to groundwater flow. Additionally, the lateral permeability heterogeneity across the unconformity imposes another important control on the local flow field. This permeability discontinuity acts as either a no-flow boundary or a constant head boundary, depending on the location of pumping.  相似文献   